- 21 8月, 2010 1 次提交
-
-
由 Matthias Bolte 提交于
With the previous storage pool UUID source not all storage pools had a proper UUID, especially GSX storage pools. The mount path is unique per host and cannot change during the lifetime of the datastore. Therefore, it's MD5 sum can be used as UUID. Use gnulib's crypto/md5 module to generate the MD5 sum.
-
- 03 8月, 2010 3 次提交
-
-
由 Matthias Bolte 提交于
Now all storage pool types expose the target path.
-
由 Matthias Bolte 提交于
Don't rely on summary.url anymore, because its value is different between an esx:// and vpx:// connection. Use host.mountInfo.path instead. Don't fallback to lookup by UUID (actually lookup by absolute path) in esxVI_LookupDatastoreByName when lookup by name fails. Add a seperate function for this: esxVI_LookupDatastoreByAbsolutePath
-
由 Matthias Bolte 提交于
Now a vpx:// connection has an explicitly specified host. This allows to enabled several functions for a vpx:// connection again, like host UUID, hostname, general node info, max vCPU count, free memory, migration and defining new domains. Lookup datacenter, compute resource, resource pool and host system once and cache them. This simplifies the rest of the code and reduces overall HTTP(S) traffic a bit. esx:// and vpx:// can be mixed freely for a migration. Ensure that migration source and destination refer to the same vCenter. Also directly encode the resource pool and host system object IDs into the migration URI in the prepare function. Then directly build managed object references in the perform function instead of re-looking up already known information.
-
- 30 7月, 2010 1 次提交
-
-
由 Matthias Bolte 提交于
-
- 25 7月, 2010 1 次提交
-
-
由 Matthias Bolte 提交于
Add a pointer to the primary context of a connection and use it in all driver functions that don't dependent on the context type. This includes almost all functions that deal with a virDomianPtr. Therefore, using a vpx:// connection allows you to perform all the usual domain related actions like start, destroy, suspend, resume, dumpxml etc. Some functions that require an explicitly specified ESX server don't work yet. This includes the host UUID, the hostname, the general node info, the max vCPU count and the free memory. Also not working yet are migration and defining new domains.
-
- 27 5月, 2010 1 次提交
-
-
由 Matthias Bolte 提交于
Eliminate almost all backward jumps by replacing this common pattern: int some_random_function(void) { int result = 0; ... cleanup: <unconditional cleanup code> return result; failure: <cleanup code in case of an error> result = -1; goto cleanup } with this simpler pattern: int some_random_function(void) { int result = -1; ... result = 0; cleanup: if (result < 0) { <cleanup code in case of an error> } <unconditional cleanup code> return result; } Add a bool success variable in functions that don't have a int result that can be used for the new pattern. Also remove some unnecessary memsets in error paths.
-
- 26 5月, 2010 1 次提交
-
-
由 Matthias Bolte 提交于
Allows listing existing pools and requesting information about them. Alter the esxVI_ProductVersion enum in a way that allows to check for product type by masking.
-
- 07 4月, 2010 1 次提交
-
-
由 Matthias Bolte 提交于
Also define ESX_ERROR and ESX_VI_ERROR in a central place, instead of defining them in each source file. Add ESX_ERROR and ESX_VI_ERROR to the msg_gen_function list in cfg.mk. Update po/POTFILES.in accordingly.
-
- 23 3月, 2010 1 次提交
-
-
由 Matthias Bolte 提交于
Replace 'method' with 'function' and get the filename's suffix right.
-
- 20 3月, 2010 1 次提交
-
-
由 David Allan 提交于
Also add vol wiping to ESX storage driver struct
-
- 08 3月, 2010 1 次提交
-
-
由 Eric Blake 提交于
Prior to this patch, there was an inconsistent mix between GNU and C99. For consistency, and potential portability to other compilers, stick with the C99 vararg macro syntax. * src/conf/cpu_conf.c (virCPUReportError): Use C99 rather than GNU vararg macro syntax. * src/conf/domain_conf.c (virDomainReportError): Likewise. * src/conf/domain_event.c (eventReportError): Likewise. * src/conf/interface_conf.c (virInterfaceReportError): Likewise. * src/conf/network_conf.c (virNetworkReportError): Likewise. * src/conf/node_device_conf.h (virNodeDeviceReportError): Likewise. * src/conf/secret_conf.h (virSecretReportError): Likewise. * src/conf/storage_conf.h (virStorageReportError): Likewise. * src/esx/esx_device_monitor.c (ESX_ERROR): Use C99 rather than GNU vararg macro syntax. * src/esx/esx_driver.c (ESX_ERROR): Likewise. * src/esx/esx_interface_driver.c (ESX_ERROR): Likewise. * src/esx/esx_network_driver.c (ESX_ERROR): Likewise. * src/esx/esx_secret_driver.c (ESX_ERROR): Likewise. * src/esx/esx_storage_driver.c (ESX_ERROR): Likewise. * src/esx/esx_util.c (ESX_ERROR): Likewise. * src/esx/esx_vi.c (ESX_VI_ERROR): Likewise. * src/esx/esx_vi_methods.c (ESX_VI_ERROR): Likewise. * src/esx/esx_vi_types.c (ESX_VI_ERROR): Likewise. * src/esx/esx_vmx.c (ESX_ERROR): Likewise. * src/util/hostusb.c (usbReportError): Use C99 rather than GNU vararg macro syntax. * src/util/json.c (virJSONError): Likewise. * src/util/macvtap.c (ReportError): Likewise. * src/util/pci.c (pciReportError): Likewise. * src/util/stats_linux.c (virStatsError): Likewise. * src/util/util.c (virUtilError): Likewise. * src/util/xml.c (virXMLError): Likewise. * src/xen/proxy_internal.c (virProxyError): Use C99 rather than GNU vararg macro syntax. * src/xen/sexpr.c (virSexprError): Likewise. * src/xen/xen_driver.c (xenUnifiedError): Likewise. * src/xen/xen_hypervisor.c (virXenError): Likewise. * src/xen/xen_inotify.c (virXenInotifyError): Likewise. * src/xen/xend_internal.c (virXendError): Likewise. * src/xen/xm_internal.c (xenXMError): Likewise. * src/xen/xs_internal.c (virXenStoreError): Likewise. * src/cpu/cpu.h (virCPUReportError): Use C99 rather than GNU vararg macro syntax. * src/datatypes.c (virLibConnError): Likewise. * src/interface/netcf_driver.c (interfaceReportError): Likewise. * src/libvirt.c (virLibStreamError): Likewise. * src/lxc/lxc_conf.h (lxcError): Likewise. * src/network/bridge_driver.c (networkReportError): Likewise. * src/nodeinfo.c (nodeReportError): Likewise. * src/opennebula/one_conf.h (oneError): Likewise. * src/openvz/openvz_conf.h (openvzError): Likewise. * src/phyp/phyp_driver.c (PHYP_ERROR): Likewise. * src/qemu/qemu_conf.h (qemuReportError): Likewise. * src/remote/remote_driver.c (errorf): Likewise. * src/security/security_driver.h (virSecurityReportError): Likewise. * src/test/test_driver.c (testError): Likewise. * src/uml/uml_conf.h (umlReportError): Likewise. * src/vbox/vbox_driver.c (vboxError): Likewise. * src/vbox/vbox_tmpl.c (vboxError): Likewise.
-
- 18 1月, 2010 1 次提交
-
-
由 Matthias Bolte 提交于
This stops libvirt from probing for a libvirtd on the ESX server and sets the base for the implementation of the secondary drivers.
-