- 02 7月, 2016 1 次提交
-
-
由 John Ferlan 提交于
In order to use more common code and set up for a future type, modify the encryption secret to allow the "usage" attribute or the "uuid" attribute to define the secret. The "usage" in the case of a volume secret would be the path to the volume as dictated by the backwards compatibility brought on by virStorageGenerateQcowEncryption where it set up the usage field as the vol->target.path and didn't allow someone to provide it. This carries into virSecretObjListFindByUsageLocked which takes the secret usage attribute value from from the domain disk definition and compares it against the usage type from the secret definition. Since none of the code dealing with qcow/qcow2 encryption secrets uses usage for lookup, it's a mostly cosmetic change. The real usage comes in a future path where the encryption is expanded to be a luks volume and the secret will allow definition of the usage field. This code will make use of the virSecretLookup{Parse|Format}Secret common code. Signed-off-by: NJohn Ferlan <jferlan@redhat.com>
-
- 27 6月, 2016 2 次提交
-
-
由 Laine Stump 提交于
For type='ethernet' interfaces only.
- 14 6月, 2016 1 次提交
-
-
由 Martin Kletzander 提交于
This option allows or disallows detection of zero-writes if it is set to "on" or "off", respectively. It can be also set to "unmap" in which case it will try discarding that part of image based on the value of the "discard" option. Signed-off-by: NMartin Kletzander <mkletzan@redhat.com>
-
- 09 6月, 2016 3 次提交
-
-
由 Pavel Hrdina 提交于
Signed-off-by: NPavel Hrdina <phrdina@redhat.com>
-
由 Pavel Hrdina 提交于
Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=1335832Signed-off-by: NPavel Hrdina <phrdina@redhat.com>
-
由 Pavel Hrdina 提交于
VNC graphics already supports sockets but only via 'socket' attribute. This patch coverts that attribute into listen type 'socket'. For backward compatibility we need to handle listen type 'socket' and 'socket' attribute properly to support old XMLs and new XMLs. If both are provided they have to match, if only one of them is provided we need to be able to parse that configuration too. To not break migration back to old libvirt if the socket is provided by user we need to generate migratable XML without the listen element and use only 'socket' attribute. Signed-off-by: NPavel Hrdina <phrdina@redhat.com>
-
- 08 6月, 2016 3 次提交
-
-
由 Tomáš Ryšavý 提交于
This function doesn't follow our convention of naming functions.
-
由 Tomáš Ryšavý 提交于
This function doesn't follow our convention of naming functions.
-
由 Tomáš Ryšavý 提交于
This function doesn't follow our convention of naming functions.
-
- 07 6月, 2016 1 次提交
-
-
由 Martin Kletzander 提交于
Historically, we added heads=1 to videos, but for example for qxl, we did not reflect that on the command line. Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=1283207Signed-off-by: NMartin Kletzander <mkletzan@redhat.com>
-
- 26 5月, 2016 1 次提交
-
-
由 Laine Stump 提交于
Hand-entering indexes for 20 PCI controllers is not as tedious as manually determining and entering their PCI addresses, but it's still annoying, and the algorithm for determining the proper index is incredibly simple (in all cases except one) - just pick the lowest unused index. The one exception is USB2 controllers because multiple controllers in the same group have the same index. For these we look to see if 1) the most recently added USB controller is also a USB2 controller, and 2) the group *that* controller belongs to doesn't yet have a controller of the exact model we're just now adding - if both are true, the new controller gets the same index, but in all other cases we just assign the lowest unused index. With this patch in place and combined with the automatic PCI address assignment, we can define a PCIe switch with several ports like this: <controller type='pci' model='pcie-root-port'/> <controller type='pci' model='pcie-switch-upstream-port'/> <controller type='pci' model='pcie-switch-downstream-port'/> <controller type='pci' model='pcie-switch-downstream-port'/> <controller type='pci' model='pcie-switch-downstream-port'/> <controller type='pci' model='pcie-switch-downstream-port'/> <controller type='pci' model='pcie-switch-downstream-port'/> ... These will each get a unique index, and PCI addresses that connect them together appropriately with no pesky numbers required.
-
- 25 5月, 2016 1 次提交
-
-
由 Ján Tomko 提交于
Add a new element to <domain> XML: <os> <acpi> <table type="slic">/path/to/acpi/table/file</table> </acpi> </os> To supply a path to a SLIC (Software Licensing) ACPI table blob. https://bugzilla.redhat.com/show_bug.cgi?id=1327537
-
- 23 5月, 2016 2 次提交
-
-
由 Ján Tomko 提交于
We support qemu version 0.12.0+, which has it.
-
由 Ján Tomko 提交于
This test requests a read-only virtual FAT drive on the IDE bus. Read-only IDE drives are unsupported, but libvirt only displays the error if it has the QEMU_CAPS_DRIVE_READONLY capability. Read-write FAT drives are also unsupported.
-
- 21 5月, 2016 1 次提交
-
-
由 Laine Stump 提交于
Rather than only assigning a PCI address when no address is given at all, also do it when the config says that the address type is 'pci', but it gives no address (virDeviceInfoPCIAddressWanted()). There are also several places after parsing but prior to address assignment where code previously expected that any info with address type='pci' would have a *valid* PCI address, which isn't always the case - now we check not only for type='pci', but also for a valid address (virDeviceInfoPCIAddressPresent()). The test case added in this patch was directly copied from Cole's patch titled: qemu: Wire up address type=pci auto_allocate
-
- 20 5月, 2016 2 次提交
-
-
由 Pavel Hrdina 提交于
Commit 55320c23 introduced a new test for VNC to test if vnc_auto_unix_socket is set in qemu.conf, but forget to enable it in qemuxml2argvtest.c. This patch also moves the code in qemuxml2xmltest.c next to other VNC tests and refactor the test so we also check the case for parsing active XML. Signed-off-by: NPavel Hrdina <phrdina@redhat.com>
-
由 Ján Tomko 提交于
We have stopped supporting Xenner some time ago.
-
- 19 5月, 2016 1 次提交
-
-
由 Cole Robinson 提交于
This wires up qemuDomainAssignAddresses into the new virDomainDefAssignAddressesCallback, so it's always triggered via virDomainDefPostParse. We are essentially doing this already with open coded calls sprinkled about. qemu argv parse output changes slightly since previously it wasn't hitting qemuDomainAssignAddresses.
-
- 18 5月, 2016 2 次提交
-
-
由 Andrea Bolognani 提交于
The only case where the hardware capabilities influence the result is when no <gic/> element was provided. The test programs now ensure both that the correct GIC version is picked in that case, and that hardware capabilities are not taken into account when the user has already picked a GIC version.
-
由 Andrea Bolognani 提交于
Now that we choose the GIC version based on hardware features when no <gic/> element has been provided, we need a way to fake the GIC capabilities of the host. Update the qemuxml2argv and qemuxml2xml tests to allow this.
-
- 04 5月, 2016 1 次提交
-
-
由 John Ferlan 提交于
Add the ability to add an 'iothread' to the controller which will be how virtio-scsi-pci and virtio-scsi-ccw iothreads have been implemented in qemu. Describe the new functionality and add tests to parse/validate that the new attribute can be added.
-
- 02 5月, 2016 1 次提交
-
-
由 Boris Fiuczynski 提交于
Signed-off-by: NBoris Fiuczynski <fiuczy@linux.vnet.ibm.com>
-
- 28 4月, 2016 1 次提交
-
-
由 Martin Kletzander 提交于
Similarly to what commit 71408079 did with some internal paths, clear vnc socket paths that were generated by us. Having such path in the definition can cause trouble when restoring the domain. The path is generated to the per-domain directory that contains the domain ID. However, that ID will be different upon restoration, so qemu won't be able to create that socket because the directory will not be prepared. To be able to migrate to older libvirt, skip formatting the socket path in migratable XML if it was autogenerated. And mark it as autogenerated if it already exists and we're parsing live XML. Best viewed with '-C'. Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=1326270Signed-off-by: NMartin Kletzander <mkletzan@redhat.com>
-
- 15 4月, 2016 3 次提交
-
-
由 Laine Stump 提交于
This controller provides a single PCIe port on a new root. It is similar to pci-expander-bus, intended to provide a bus that can be associated with a guest-identifiable NUMA node, but is for machinetypes with PCIe rather than PCI (e.g. q35-based machinetypes). Aside from PCIe vs. PCI, the other main difference is that a pci-expander-bus has a companion pci-bridge that is automatically attached along with it, but pcie-expander-bus has only a single port, and that port will only connect to a pcie-root-port, or to a pcie-switch-upstream-port. In order for the bus to be of any use in the guest, it must have either a pcie-root-port or a pcie-switch-upstream-port attached (and one or more pcie-switch-downstream-ports attached to the pcie-switch-upstream-port).
-
由 Laine Stump 提交于
This is a standard PCI root bus (not a bridge) that can be added to a 440fx-based domain. Although it uses a PCI slot, this is *not* how it is connected into the PCI bus hierarchy, but is only used for control. Each pci-expander-bus provides 32 slots (0-31) that can accept hotplug of standard PCI devices. The usefulness of pci-expander-bus relative to a pci-bridge is that the NUMA node of the bus can be specified with the <node> subelement of <target>. This gives guest-side visibility to the NUMA node of attached devices (presuming that management apps only assign a device to a bus that has a NUMA node number matching the node number of the device on the host). Each pci-expander-bus also has a "busNr" attribute. The expander-bus itself will take the busNr specified, and all buses that are connected to this bus (including the pci-bridge that is automatically added to any expander bus of model "pxb" (see the next commit)) will use busNr+1, busNr+2, etc, and the pci-root (or the expander-bus with next lower busNr) will use bus numbers lower than busNr.
-
由 Cole Robinson 提交于
This allows tests to check for specific failure scenarios
-
- 13 4月, 2016 1 次提交
-
-
由 Ján Tomko 提交于
After removing qemuBuildCommandLineCallbacks, testutilsqemu.h does not need to include qemu_command.h. Include just qemu_conf.h here and qemu_domain_address.h in files that need it.
-
- 11 4月, 2016 1 次提交
-
-
由 Pavel Hrdina 提交于
Commit dc98a5bc refactored the code a lot and forget about checking if listen attribute is specified. This ensures that listen attribute and first listen element are compared only if both exist. Signed-off-by: NPavel Hrdina <phrdina@redhat.com>
-
- 01 3月, 2016 2 次提交
-
-
由 Marc-André Lureau 提交于
Add Spice graphics gl attribute. qemu 2.6 should have -spice gl=on argument to enable opengl rendering context (patches on the ML). This is necessary to actually enable virgl rendering. Add a qemuxml2argv test for virtio-gpu + spice with virgl. Signed-off-by: NMarc-André Lureau <marcandre.lureau@redhat.com> Signed-off-by: NMichal Privoznik <mprivozn@redhat.com>
-
由 Martin Kletzander 提交于
Per-domain directories were introduced in order to be able to completely separate security labels for each domain (commit f1f68ca3). However when the domain name is long (let's say a ridiculous 110 characters), we cannot connect to the monitor socket because on length of UNIX socket address is limited. In order to get around this, let's shorten it in similar fashion and in order to avoid conflicts, throw in an ID there as well. Also save that into the status XML and load the old status XMLs properly (to clean up after older domains). That way we can change it in the future. The shortening can be seen in qemuxml2argv tests, for example in the hugepages-pages2 case. Signed-off-by: NMartin Kletzander <mkletzan@redhat.com>
-
- 26 2月, 2016 1 次提交
-
-
由 Ján Tomko 提交于
Allow testing XML parsing with different flags.
-
- 22 2月, 2016 1 次提交
-
-
由 Paolo Bonzini 提交于
This does nothing more than adding the new device and capability. The device is present since QEMU 2.6.0. Signed-off-by: NPaolo Bonzini <pbonzini@redhat.com> Signed-off-by: NDaniel P. Berrange <berrange@redhat.com>
-
- 16 2月, 2016 2 次提交
-
-
由 Andrea Bolognani 提交于
Test all kinds of scenarios, including guests asking for GIC but failing to specify a version, guests specifying an invalid version and guests trying to use GIC with non-virt or even non-ARM machines.
-
由 Andrea Bolognani 提交于
Unify the naming to prepare for new test cases that will be added later on. Convert a couple of output XML files for the qemuxml2xml test to symlinks while at it, since they were identical to the corresponding input XML files anyways. Moreover, since we're only interested in testing GIC support here, simplify XML files by getting rid of the unrelevant bits.
-
- 10 2月, 2016 5 次提交
-
-
由 Cole Robinson 提交于
Clarify the point of some of the test cases by renaming them. Add more xml2xml tests.
-
由 Cole Robinson 提交于
We use the PreFormat callback for this. Many test cases need to be extended to pass in proper qemuCaps flags so AssignAddresses doesn't throw errors. One test case (pcie-root-port-too-many) is dropped, since it was meant only for checking an error condition in qemuxml2argv, and one we add in AssignAddresses it errors here too. Long term I think AssignAddresses should be handled in qemu's PostParse callback, but that's not entirely straightforward. Handling it here means we can get the test suite churn over with.
-
由 Cole Robinson 提交于
This allows individual driver tests to hook in their own code before the def is formatted and compared. We will eventually use this in the qemuxml2xml
-
由 Cole Robinson 提交于
Similar to how we do it for qemuxml2argvtest. This will be used in future patches.
-
由 Cole Robinson 提交于
QEMU_CAPS_DEVICE is always enabled for qemu binaries we support. Sync qemuxml2* to match, and regenerate all test output.
-