- 07 6月, 2016 1 次提交
-
-
由 Martin Kletzander 提交于
Historically, we added heads=1 to videos, but for example for qxl, we did not reflect that on the command line. Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=1283207Signed-off-by: NMartin Kletzander <mkletzan@redhat.com>
-
- 26 5月, 2016 1 次提交
-
-
由 Laine Stump 提交于
Hand-entering indexes for 20 PCI controllers is not as tedious as manually determining and entering their PCI addresses, but it's still annoying, and the algorithm for determining the proper index is incredibly simple (in all cases except one) - just pick the lowest unused index. The one exception is USB2 controllers because multiple controllers in the same group have the same index. For these we look to see if 1) the most recently added USB controller is also a USB2 controller, and 2) the group *that* controller belongs to doesn't yet have a controller of the exact model we're just now adding - if both are true, the new controller gets the same index, but in all other cases we just assign the lowest unused index. With this patch in place and combined with the automatic PCI address assignment, we can define a PCIe switch with several ports like this: <controller type='pci' model='pcie-root-port'/> <controller type='pci' model='pcie-switch-upstream-port'/> <controller type='pci' model='pcie-switch-downstream-port'/> <controller type='pci' model='pcie-switch-downstream-port'/> <controller type='pci' model='pcie-switch-downstream-port'/> <controller type='pci' model='pcie-switch-downstream-port'/> <controller type='pci' model='pcie-switch-downstream-port'/> ... These will each get a unique index, and PCI addresses that connect them together appropriately with no pesky numbers required.
-
- 25 5月, 2016 1 次提交
-
-
由 Ján Tomko 提交于
Add a new element to <domain> XML: <os> <acpi> <table type="slic">/path/to/acpi/table/file</table> </acpi> </os> To supply a path to a SLIC (Software Licensing) ACPI table blob. https://bugzilla.redhat.com/show_bug.cgi?id=1327537
-
- 23 5月, 2016 1 次提交
-
-
由 Ján Tomko 提交于
Read-only IDE disks are not supported, but the error is raised only when QEMU_CAPS_DRIVE_READONLY is set.
-
- 21 5月, 2016 2 次提交
-
-
由 Cole Robinson 提交于
This is an interesting test case since PCI isn't the default for aarch64.
-
由 Laine Stump 提交于
Rather than only assigning a PCI address when no address is given at all, also do it when the config says that the address type is 'pci', but it gives no address (virDeviceInfoPCIAddressWanted()). There are also several places after parsing but prior to address assignment where code previously expected that any info with address type='pci' would have a *valid* PCI address, which isn't always the case - now we check not only for type='pci', but also for a valid address (virDeviceInfoPCIAddressPresent()). The test case added in this patch was directly copied from Cole's patch titled: qemu: Wire up address type=pci auto_allocate
-
- 20 5月, 2016 3 次提交
-
-
由 Pavel Hrdina 提交于
Commit 55320c23 introduced a new test for VNC to test if vnc_auto_unix_socket is set in qemu.conf, but forget to enable it in qemuxml2argvtest.c. This patch also moves the code in qemuxml2xmltest.c next to other VNC tests and refactor the test so we also check the case for parsing active XML. Signed-off-by: NPavel Hrdina <phrdina@redhat.com>
-
由 Pavel Hrdina 提交于
Signed-off-by: NPavel Hrdina <phrdina@redhat.com>
-
由 Ján Tomko 提交于
We have stopped supporting Xenner some time ago.
-
- 18 5月, 2016 1 次提交
-
-
由 Andrea Bolognani 提交于
The only case where the hardware capabilities influence the result is when no <gic/> element was provided. The test programs now ensure both that the correct GIC version is picked in that case, and that hardware capabilities are not taken into account when the user has already picked a GIC version.
-
- 17 5月, 2016 1 次提交
-
-
由 Pavel Hrdina 提交于
We support omitting listen attribute of graphics element so we should also support omitting address attribute of listen element. This patch also updates libvirt to always add a listen element into domain XML except for VNC graphics if socket attribute is specified. Signed-off-by: NPavel Hrdina <phrdina@redhat.com>
-
- 04 5月, 2016 1 次提交
-
-
由 John Ferlan 提交于
Add the ability to add an 'iothread' to the controller which will be how virtio-scsi-pci and virtio-scsi-ccw iothreads have been implemented in qemu. Describe the new functionality and add tests to parse/validate that the new attribute can be added.
-
- 02 5月, 2016 2 次提交
-
-
由 Boris Fiuczynski 提交于
Signed-off-by: NBoris Fiuczynski <fiuczy@linux.vnet.ibm.com>
-
由 Boris Fiuczynski 提交于
This patch adds by default a panic device with model s390 to S390 guests. Signed-off-by: NBoris Fiuczynski <fiuczy@linux.vnet.ibm.com>
-
- 28 4月, 2016 1 次提交
-
-
由 Martin Kletzander 提交于
Similarly to what commit 71408079 did with some internal paths, clear vnc socket paths that were generated by us. Having such path in the definition can cause trouble when restoring the domain. The path is generated to the per-domain directory that contains the domain ID. However, that ID will be different upon restoration, so qemu won't be able to create that socket because the directory will not be prepared. To be able to migrate to older libvirt, skip formatting the socket path in migratable XML if it was autogenerated. And mark it as autogenerated if it already exists and we're parsing live XML. Best viewed with '-C'. Resolves: https://bugzilla.redhat.com/show_bug.cgi?id=1326270Signed-off-by: NMartin Kletzander <mkletzan@redhat.com>
-
- 26 4月, 2016 2 次提交
-
-
由 Cole Robinson 提交于
Currently we only allow /dev/random and /dev/hwrng as host input for <rng><backend model='random'/> device. This was added after various upstream discussions in commit 4932ef45 However this restriction has generated quite a few complaints over the years, so a new discussion was initiated: http://www.redhat.com/archives/libvir-list/2016-April/msg00987.html Several people suggested removing the restriction, and nobody really spoke up to defend it. So this patch drops the path restriction entirely https://bugzilla.redhat.com/show_bug.cgi?id=1074464
-
由 Cole Robinson 提交于
The hex range already tried to allow for it, but it wasn't using the correct XML hex syntax. Fix it, and test it
-
- 19 4月, 2016 1 次提交
-
-
由 John Ferlan 提交于
While working on the tests for the secret initialization vector, I found that the existing iSCSI tests were lacking in how they defined the IQN. Many had IQN's of just 'iqn.1992-01.com.example' for one disk while using 'iqn.1992-01.com.example/1' for the second disk (same for hostdevs - guess how they were copied/generated). Typically (and documented this way), IQN's would include be of the form 'iqn.1992-01.com.example:storage/1' indicating an IQN using "storage" for naming authority specific string and "/1" for the iSCSI LUN. So modify the input XML's to use the more proper format - this of course has a ripple effect on the output XML and the args. Also note that the "%3A" is generated by the virURIFormat/xmlSaveUri to represent the colon. Signed-off-by: NJohn Ferlan <jferlan@redhat.com>
-
- 15 4月, 2016 4 次提交
-
-
由 Laine Stump 提交于
This controller provides a single PCIe port on a new root. It is similar to pci-expander-bus, intended to provide a bus that can be associated with a guest-identifiable NUMA node, but is for machinetypes with PCIe rather than PCI (e.g. q35-based machinetypes). Aside from PCIe vs. PCI, the other main difference is that a pci-expander-bus has a companion pci-bridge that is automatically attached along with it, but pcie-expander-bus has only a single port, and that port will only connect to a pcie-root-port, or to a pcie-switch-upstream-port. In order for the bus to be of any use in the guest, it must have either a pcie-root-port or a pcie-switch-upstream-port attached (and one or more pcie-switch-downstream-ports attached to the pcie-switch-upstream-port).
-
由 Laine Stump 提交于
This is backed by the qemu device "pxb". The pxb device always includes a pci-bridge that is at the bus number of the pxb + 1. busNr and <node> from the <target> subelement are used to set the bus_nr and numa_node options for pxb. During post-parse we validate that the domain's machinetype is 440fx-based (since the pxb device only works on 440fx-based machines), and <node> also gets a sanity check to assure that the NUMA node specified for the pxb (if any - it's optional) actually exists on the guest.
-
由 Laine Stump 提交于
This is a standard PCI root bus (not a bridge) that can be added to a 440fx-based domain. Although it uses a PCI slot, this is *not* how it is connected into the PCI bus hierarchy, but is only used for control. Each pci-expander-bus provides 32 slots (0-31) that can accept hotplug of standard PCI devices. The usefulness of pci-expander-bus relative to a pci-bridge is that the NUMA node of the bus can be specified with the <node> subelement of <target>. This gives guest-side visibility to the NUMA node of attached devices (presuming that management apps only assign a device to a bus that has a NUMA node number matching the node number of the device on the host). Each pci-expander-bus also has a "busNr" attribute. The expander-bus itself will take the busNr specified, and all buses that are connected to this bus (including the pci-bridge that is automatically added to any expander bus of model "pxb" (see the next commit)) will use busNr+1, busNr+2, etc, and the pci-root (or the expander-bus with next lower busNr) will use bus numbers lower than busNr.
-
由 Laine Stump 提交于
When support for dmi-to-pci-bridge was added, it was assumed that, just as with the pci-root bus, slot 0 was reserved. This is not the case - it can be used to connect a device just like any other slot, so remove the restriction and update the test cases that auto-assign an address on a dmi-to-pci-bridge.
-
- 11 4月, 2016 1 次提交
-
-
由 Pavel Hrdina 提交于
Commit dc98a5bc refactored the code a lot and forget about checking if listen attribute is specified. This ensures that listen attribute and first listen element are compared only if both exist. Signed-off-by: NPavel Hrdina <phrdina@redhat.com>
-
- 29 3月, 2016 1 次提交
-
-
由 Maxim Nestratov 提交于
This patch adds support for "vpindex", "runtime", "synic", "stimer", and "vendor_id" features available in qemu 2.5+. - When Hyper-V "vpindex" is on, guest can use MSR HV_X64_MSR_VP_INDEX to get virtual processor ID. - Hyper-V "runtime" enlightement feature allows to use MSR HV_X64_MSR_VP_RUNTIME to get the time the virtual processor consumes running guest code, as well as the time the hypervisor spends running code on behalf of that guest. - Hyper-V "synic" stands for Synthetic Interrupt Controller, which is lapic extension controlled via MSRs. - Hyper-V "stimer" switches on Hyper-V SynIC timers MSR's support. Guest can setup and use fired by host events (SynIC interrupt and appropriate timer expiration message) as guest clock events - Hyper-V "reset" allows guest to reset VM. - Hyper-V "vendor_id" exposes hypervisor vendor id to guest. Signed-off-by: NNikolay Shirokovskiy <nshirokovskiy@virtuozzo.com> Signed-off-by: NJohn Ferlan <jferlan@redhat.com>
-
- 01 3月, 2016 3 次提交
-
-
由 Alexander Burluka 提交于
Signed-off-by: NAlexander Burluka <aburluka@virtuozzo.com>
-
由 Pavel Hrdina 提交于
We always place primary video device at first place, to make it easier to create a qemu command or format an xml, but we should also set the primary boolean for primary video device to 'true'. Signed-off-by: NPavel Hrdina <phrdina@redhat.com>
-
由 Marc-André Lureau 提交于
Add Spice graphics gl attribute. qemu 2.6 should have -spice gl=on argument to enable opengl rendering context (patches on the ML). This is necessary to actually enable virgl rendering. Add a qemuxml2argv test for virtio-gpu + spice with virgl. Signed-off-by: NMarc-André Lureau <marcandre.lureau@redhat.com> Signed-off-by: NMichal Privoznik <mprivozn@redhat.com>
-
- 22 2月, 2016 1 次提交
-
-
由 Paolo Bonzini 提交于
This does nothing more than adding the new device and capability. The device is present since QEMU 2.6.0. Signed-off-by: NPaolo Bonzini <pbonzini@redhat.com> Signed-off-by: NDaniel P. Berrange <berrange@redhat.com>
-
- 16 2月, 2016 3 次提交
-
-
由 Andrea Bolognani 提交于
Test all kinds of scenarios, including guests asking for GIC but failing to specify a version, guests specifying an invalid version and guests trying to use GIC with non-virt or even non-ARM machines.
-
由 Andrea Bolognani 提交于
Unify the naming to prepare for new test cases that will be added later on. Convert a couple of output XML files for the qemuxml2xml test to symlinks while at it, since they were identical to the corresponding input XML files anyways. Moreover, since we're only interested in testing GIC support here, simplify XML files by getting rid of the unrelevant bits.
-
由 Andrea Bolognani 提交于
GIC is always available to ARM virt machines, and the domain XML should reflect this fact.
-
- 10 2月, 2016 3 次提交
-
-
由 Cole Robinson 提交于
Clarify the point of some of the test cases by renaming them. Add more xml2xml tests.
-
由 Cole Robinson 提交于
We use the PreFormat callback for this. Many test cases need to be extended to pass in proper qemuCaps flags so AssignAddresses doesn't throw errors. One test case (pcie-root-port-too-many) is dropped, since it was meant only for checking an error condition in qemuxml2argv, and one we add in AssignAddresses it errors here too. Long term I think AssignAddresses should be handled in qemu's PostParse callback, but that's not entirely straightforward. Handling it here means we can get the test suite churn over with.
-
由 Cole Robinson 提交于
When we unconditionally enable QEMU_CAPS_DEVICE, these tests need some massaging, so do it ahead of time to not mix it in with the big test refresh. - minimal-s390 is not a real world working config, so drop it - disk-usb was testing for an old code path that will be removed. instead use it to test lack of USB disk support, and rename it to disk-usb-nosupport. Switch xml2xml to use disk-usb-device for input. - cputune-numatune was needlessly using q35, switch it to an older machine type
-
- 09 2月, 2016 1 次提交
-
-
由 Cole Robinson 提交于
Most qemuxml2xml tests expect that the input XML is unchanged after parsing. This is unlike 99% of new qemu configs in the wild, which after initial parsing end up with stable PCI device addresses. The xml2xml bit doesn't currently hit that code path though, so most XML testing indeed does not change. Future patches will add that PCI address bits, which means most test cases will have different output. So let's do away with the hardcoded same vs different test split, and always track a separate output file. Tests can still have same input and output, it just necessitates 2 separate XML files.
-
- 08 2月, 2016 1 次提交
-
-
由 Peter Krempa 提交于
Similarly to previous commit change the way how iothread scheduler info is stored and clean up a lot of unnecessary code.
-
- 27 1月, 2016 1 次提交
-
-
由 Pavel Hrdina 提交于
The current code was a little bit odd. At first we've removed all possible implicit input devices from domain definition to add them later back if there was any graphics device defined while parsing XML description. That's not all, while formating domain definition to XML description we at first ignore any input devices with bus different to USB and VIRTIO and few lines later we add implicit input devices to XML. This seems to me as a lot of code for nothing. This patch may look to be more complicated than original approach, but this is a preferred way to modify/add driver specific stuff only in those drivers and not deal with them in common parsing/formating functions. The update is to add those implicit input devices into config XML to follow the real HW configuration visible by guest OS. There was also inconsistence between our behavior and QEMU's in the way, that in QEMU there is no way how to disable those implicit input devices for x86 architecture and they are available always, even without graphics device. This applies also to XEN hypervisor. VZ driver already does its part by putting correct implicit devices into live XML. Signed-off-by: NPavel Hrdina <phrdina@redhat.com>
-
- 26 1月, 2016 1 次提交
-
-
由 Peter Krempa 提交于
A future patch will refactor the storage of the pinning information in a way where the ordering will be lost. Order them numerically to avoid changing the tests later.
-
- 12 1月, 2016 1 次提交
-
-
由 Laine Stump 提交于
The real Q35 machine puts the first USB controller set (EHCI+(UHCIx4)) on bus 0 slot 0x1D, and the 2nd USB controller set on bus 0 slot 0x1A, so let's attempt to make the virtual machine match that for controllers with auto-assigned addresses when possible. Three test cases were added to assure that the proper addresses are assigned - one with a single set of unaddressed USB controllers, one with 3 (to grab both preferred slots plus one more), and one with the order of the controller definitions reordered, to assure that the auto-assignment isn't mixed up by order.
-
- 25 11月, 2015 1 次提交
-
-
由 Dmitry Andreev 提交于
Panic device type used depends on 'model' attribute. If no model is specified then device type depends on hypervisor and guest arch. 'pseries' model is used for pSeries guest and 'isa' model is used in other cases. XML: <devices> <panic model='hyperv'/> </devices> QEMU command line: qemu -cpu <cpu_model>,hv_crash
-