提交 90adeaad 编写于 作者: J Ján Tomko

storage: return -1 when fs pool can't be mounted

Don't reuse the return value of virStorageBackendFileSystemIsMounted.
If it's 0, we'd return it even if the mount command failed.

Also, don't report another error if it's -1, since one has already
been reported.

Introduced by 258e06c8.

https://bugzilla.redhat.com/show_bug.cgi?id=981251
(cherry picked from commit 13fde7ce)
上级 c8c1653f
......@@ -352,6 +352,7 @@ virStorageBackendFileSystemMount(virStoragePoolObjPtr pool) {
pool->def->source.format == VIR_STORAGE_POOL_NETFS_GLUSTERFS);
virCommandPtr cmd = NULL;
int ret = -1;
int rc;
if (pool->def->type == VIR_STORAGE_POOL_NETFS) {
if (pool->def->source.nhost != 1) {
......@@ -378,10 +379,12 @@ virStorageBackendFileSystemMount(virStoragePoolObjPtr pool) {
}
/* Short-circuit if already mounted */
if ((ret = virStorageBackendFileSystemIsMounted(pool)) != 0) {
virReportError(VIR_ERR_OPERATION_INVALID,
_("Target '%s' is already mounted"),
pool->def->target.path);
if ((rc = virStorageBackendFileSystemIsMounted(pool)) != 0) {
if (rc == 1) {
virReportError(VIR_ERR_OPERATION_INVALID,
_("Target '%s' is already mounted"),
pool->def->target.path);
}
return -1;
}
......
Markdown is supported
0% .
You are about to add 0 people to the discussion. Proceed with caution.
先完成此消息的编辑!
想要评论请 注册