提交 7432141c 编写于 作者: S Scott Garfinkle 提交者: John Ferlan

Use unsigned timeout in cmdMigrateSetMaxDowntime

While looking to implement a migrate-getmaxdowntime command (coming),
I noticed that the setmaxdowntime is incorrectly looking at its
parameter as a signed longlong. Not sure how that got past gcc, but
here's a simple patch to make the command line parsing and the parameter to
the worker functions all have the correct (unsigned) type.
Signed-off-by: NScott Garfinkle <seg@us.ibm.com>
上级 fde0dff6
......@@ -10696,13 +10696,13 @@ static bool
cmdMigrateSetMaxDowntime(vshControl *ctl, const vshCmd *cmd)
{
virDomainPtr dom = NULL;
long long downtime = 0;
unsigned long long downtime = 0;
bool ret = false;
if (!(dom = virshCommandOptDomain(ctl, cmd, NULL)))
return false;
if (vshCommandOptLongLong(ctl, cmd, "downtime", &downtime) < 0)
if (vshCommandOptULongLong(ctl, cmd, "downtime", &downtime) < 0)
goto done;
if (downtime < 1) {
vshError(ctl, "%s", _("migrate: Invalid downtime"));
......
Markdown is supported
0% .
You are about to add 0 people to the discussion. Proceed with caution.
先完成此消息的编辑!
想要评论请 注册