Use unsigned timeout in cmdMigrateSetMaxDowntime
While looking to implement a migrate-getmaxdowntime command (coming),
I noticed that the setmaxdowntime is incorrectly looking at its
parameter as a signed longlong. Not sure how that got past gcc, but
here's a simple patch to make the command line parsing and the parameter to
the worker functions all have the correct (unsigned) type.