提交 72908c74 编写于 作者: O Osier Yang

block_resize: Expose the new API to virsh

上级 d1a6c77a
......@@ -6091,6 +6091,63 @@ cmdBlockJob(vshControl *ctl, const vshCmd *cmd)
return true;
}
/*
* "blockresize" command
*/
static const vshCmdInfo info_block_resize[] = {
{"help", N_("Resize block device of domain.")},
{"desc", N_("Resize block device of domain.")},
{NULL, NULL}
};
static const vshCmdOptDef opts_block_resize[] = {
{"domain", VSH_OT_DATA, VSH_OFLAG_REQ, N_("domain name, id or uuid")},
{"path", VSH_OT_DATA, VSH_OFLAG_REQ, N_("Fully-qualified path of block device")},
{"size", VSH_OT_INT, VSH_OFLAG_REQ, N_("New size of the block device in kilobytes, "
"the size must be integer")},
{NULL, 0, 0, NULL}
};
static bool
cmdBlockResize(vshControl *ctl, const vshCmd *cmd)
{
virDomainPtr dom;
const char *path = NULL;
unsigned long long size = 0;
unsigned int flags = 0;
int ret = false;
if (!vshConnectionUsability(ctl, ctl->conn))
return false;
if (vshCommandOptString(cmd, "path", (const char **) &path) < 0) {
vshError(ctl, "%s", _("Path must not be empty"));
return false;
}
if (vshCommandOptULongLong(cmd, "size", &size) < 0) {
vshError(ctl, "%s", _("Unable to parse integer"));
return false;
}
if (size > ULLONG_MAX / 1024) {
vshError(ctl, _("Size must be less than %llu"), ULLONG_MAX / 1024);
return false;
}
if (!(dom = vshCommandOptDomain(ctl, cmd, NULL)))
return false;
if (virDomainBlockResize(dom, path, size, flags) < 0) {
vshError(ctl, _("Failed to resize block device '%s'"), path);
} else {
vshPrint(ctl, _("Block device '%s' is resized"), path);
ret = true;
}
virDomainFree(dom);
return ret;
}
/*
* "net-autostart" command
......@@ -14761,6 +14818,7 @@ static const vshCmdDef domManagementCmds[] = {
{"blkiotune", cmdBlkiotune, opts_blkiotune, info_blkiotune, 0},
{"blockpull", cmdBlockPull, opts_block_pull, info_block_pull, 0},
{"blockjob", cmdBlockJob, opts_block_job, info_block_job, 0},
{"blockresize", cmdBlockResize, opts_block_resize, info_block_resize, 0},
#ifndef WIN32
{"console", cmdConsole, opts_console, info_console, 0},
#endif
......
......@@ -590,6 +590,12 @@ If I<--info> is specified, the active job information on the specified
disk will be printed.
I<bandwidth> can be used to set bandwidth limit for the active job.
=item B<blockresize> I<domain> I<--path> I<--size>
Resize a block device of domain while the domain is running, I<--path>
specifies the absolute path of the block device, I<--size> specifies the
new size in kilobytes
=item B<dominfo> I<domain-id>
Returns basic information about the domain.
......
Markdown is supported
0% .
You are about to add 0 people to the discussion. Proceed with caution.
先完成此消息的编辑!
想要评论请 注册