formatdomain.html.in 244.4 KB
Newer Older
1 2 3
<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Strict//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-strict.dtd">
<html xmlns="http://www.w3.org/1999/xhtml">
4 5 6
  <body>
    <h1>Domain XML format</h1>

D
Daniel P. Berrange 已提交
7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
    <ul id="toc"></ul>

    <p>
      This section describes the XML format used to represent domains, there are
      variations on the format based on the kind of domains run and the options
      used to launch them. For hypervisor specific details consult the
      <a href="drivers.html">driver docs</a>
    </p>


    <h2><a name="elements">Element and attribute overview</a></h2>

    <p>
      The root element required for all virtual machines is
      named <code>domain</code>. It has two attributes, the
      <code>type</code> specifies the hypervisor used for running
      the domain. The allowed values are driver specific, but
      include "xen", "kvm", "qemu", "lxc" and "kqemu". The
      second attribute is <code>id</code> which is a unique
      integer identifier for the running guest machine. Inactive
      machines have no id value.
    </p>


    <h3><a name="elementsMetadata">General metadata</a></h3>

33 34 35 36
<pre>
&lt;domain type='xen' id='3'&gt;
  &lt;name&gt;fv0&lt;/name&gt;
  &lt;uuid&gt;4dea22b31d52d8f32516782e98ab3fa0&lt;/uuid&gt;
37
  &lt;title&gt;A short description - title - of the domain&lt;/title&gt;
38
  &lt;description&gt;Some human readable description&lt;/description&gt;
39 40 41 42
  &lt;metadata&gt;
    &lt;app1:foo xmlns:app1="http://app1.org/app1/"&gt;..&lt;/app1:foo&gt;
    &lt;app2:bar xmlns:app2="http://app1.org/app2/"&gt;..&lt;/app2:bar&gt;
  &lt;/metadata&gt;
43
  ...</pre>
D
Daniel P. Berrange 已提交
44 45 46 47

    <dl>
      <dt><code>name</code></dt>
      <dd>The content of the <code>name</code> element provides
M
Matthew Booth 已提交
48 49 50 51 52
        a short name for the virtual machine. This name should
        consist only of alpha-numeric characters and is required
        to be unique within the scope of a single host. It is
        often used to form the filename for storing the persistent
        configuration file. <span class="since">Since 0.0.1</span></dd>
D
Daniel P. Berrange 已提交
53 54
      <dt><code>uuid</code></dt>
      <dd>The content of the <code>uuid</code> element provides
M
Matthew Booth 已提交
55
        a globally unique identifier for the virtual machine.
E
Eric Blake 已提交
56 57
        The format must be RFC 4122 compliant,
        eg <code>3e3fce45-4f53-4fa7-bb32-11f34168b82b</code>.
M
Matthew Booth 已提交
58
        If omitted when defining/creating a new machine, a random
59 60 61 62
        UUID is generated. It is also possible to provide the UUID
        via a <a href="#elementsSysinfo"><code>sysinfo</code></a>
        specification. <span class="since">Since 0.0.1, sysinfo
        since 0.8.7</span></dd>
63

64 65 66 67 68
      <dt><code>title</code></dt>
      <dd>The optional element <code>title</code> provides space for a
        short description of the domain. The title should not contain
        any newlines. <span class="since">Since 0.9.10</span>.</dd>

69 70
      <dt><code>description</code></dt>
      <dd>The content of the <code>description</code> element provides a
71 72 73 74 75 76 77 78 79 80 81 82
        human readable description of the virtual machine. This data is not
        used by libvirt in any way, it can contain any information the user
        wants. <span class="since">Since 0.7.2</span></dd>

      <dt><code>metadata</code></dt>
      <dd>The <code>metadata</code> node can be used by applications
        to store custom metadata in the form of XML
        nodes/trees. Applications must use custom namespaces on their
        XML nodes/trees, with only one top-level element per namespace
        (if the application needs structure, they should have
        sub-elements to their namespace
        element). <span class="since">Since 0.9.10</span></dd>
83
   </dl>
D
Daniel P. Berrange 已提交
84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100

    <h3><a name="elementsOS">Operating system booting</a></h3>

    <p>
      There are a number of different ways to boot virtual machines
      each with their own pros and cons.
    </p>

    <h4><a name="elementsOSBIOS">BIOS bootloader</a></h4>

    <p>
      Booting via the BIOS is available for hypervisors supporting
      full virtualization. In this case the BIOS has a boot order
      priority (floppy, harddisk, cdrom, network) determining where
      to obtain/find the boot image.
    </p>

101 102 103 104
<pre>
  ...
  &lt;os&gt;
    &lt;type&gt;hvm&lt;/type&gt;
105
    &lt;loader readonly='yes' type='rom'&gt;/usr/lib/xen/boot/hvmloader&lt;/loader&gt;
106
    &lt;nvram template='/usr/share/OVMF/OVMF_VARS.fd'&gt;/var/lib/libvirt/nvram/guest_VARS.fd&lt;/nvram&gt;
107
    &lt;boot dev='hd'/&gt;
108
    &lt;boot dev='cdrom'/&gt;
109
    &lt;bootmenu enable='yes' timeout='3000'/&gt;
110
    &lt;smbios mode='sysinfo'/&gt;
111
    &lt;bios useserial='yes' rebootTimeout='0'/&gt;
112 113
  &lt;/os&gt;
  ...</pre>
D
Daniel P. Berrange 已提交
114 115 116 117

    <dl>
      <dt><code>type</code></dt>
      <dd>The content of the <code>type</code> element specifies the
M
Matthew Booth 已提交
118 119 120 121 122
        type of operating system to be booted in the virtual machine.
        <code>hvm</code> indicates that the OS is one designed to run
        on bare metal, so requires full virtualization. <code>linux</code>
        (badly named!) refers to an OS that supports the Xen 3 hypervisor
        guest ABI. There are also two optional attributes, <code>arch</code>
E
Eric Blake 已提交
123 124 125 126 127
        specifying the CPU architecture to virtualization,
        and <code>machine</code> referring to the machine
        type. The <a href="formatcaps.html">Capabilities XML</a>
        provides details on allowed values for
        these. <span class="since">Since 0.0.1</span></dd>
D
Daniel P. Berrange 已提交
128 129
      <dt><code>loader</code></dt>
      <dd>The optional <code>loader</code> tag refers to a firmware blob
130 131 132
        used to assist the domain creation process. It is used by Xen
        fully virtualized domains as well as setting the QEMU BIOS file
        path for QEMU/KVM domains. <span class="since">Xen since 0.1.0,
133 134 135 136 137 138 139 140 141 142 143 144
        QEMU/KVM since 0.9.12</span> Then, <span class="since">since
        1.2.8</span> it's possible for the element to have two
        optional attributes: <code>readonly</code> (accepted values are
        <code>yes</code> and <code>no</code>) to reflect the fact that the
        image should be writable or read-only. The second attribute
        <code>type</code> accepts values <code>rom</code> and
        <code>pflash</code>. It tells the hypervisor where in the guest
        memory the file should be mapped.  For instance, if the loader
        path points to an UEFI image, <code>type</code> should be
        <code>pflash</code>.</dd>
      <dt><code>nvram</code></dt>
      <dd>Some UEFI firmwares may want to use a non-volatile memory to store
145 146 147 148 149
        some variables. In the host, this is represented as a file and the path
        to the file is stored in this element. Moreover, when the domain is
        started up libvirt copies so called master NVRAM store file defined
        in <code>qemu.conf</code>. If needed, the <code>template</code>
        attribute can be used to per domain override map of master NVRAM stores
150 151 152 153
        from the config file. Note, that for transient domains if the NVRAM file
        has been created by libvirt it is left behind and it is management
        application's responsibility to save and remove file (if needed to be
        persistent). <span class="since">Since 1.2.8</span></dd>
D
Daniel P. Berrange 已提交
154 155
      <dt><code>boot</code></dt>
      <dd>The <code>dev</code> attribute takes one of the values "fd", "hd",
M
Matthew Booth 已提交
156 157
        "cdrom" or "network" and is used to specify the next boot device
        to consider. The <code>boot</code> element can be repeated multiple
158 159 160 161 162 163 164 165 166 167 168 169
        times to setup a priority list of boot devices to try in turn.
        Multiple devices of the same type are sorted according to their
        targets while preserving the order of buses. After defining the
        domain, its XML configuration returned by libvirt (through
        virDomainGetXMLDesc) lists devices in the sorted order. Once sorted,
        the first device is marked as bootable. Thus, e.g., a domain
        configured to boot from "hd" with vdb, hda, vda, and hdc disks
        assigned to it will boot from vda (the sorted list is vda, vdb, hda,
        hdc). Similar domain with hdc, vda, vdb, and hda disks will boot from
        hda (sorted disks are: hda, hdc, vda, vdb). It can be tricky to
        configure in the desired way, which is why per-device boot elements
        (see <a href="#elementsDisks">disks</a>,
170
        <a href="#elementsNICS">network interfaces</a>, and
171
        <a href="#elementsHostDev">USB and PCI devices</a> sections below) were
172 173 174 175
        introduced and they are the preferred way providing full control over
        booting order. The <code>boot</code> element and per-device boot
        elements are mutually exclusive. <span class="since">Since 0.1.3,
        per-device boot since 0.8.8</span>
D
Daniel P. Berrange 已提交
176
      </dd>
177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201
      <dt><code>smbios</code></dt>
      <dd>How to populate SMBIOS information visible in the guest.
        The <code>mode</code> attribute must be specified, and is either
        "emulate" (let the hypervisor generate all values), "host" (copy
        all of Block 0 and Block 1, except for the UUID, from the host's
        SMBIOS values;
        the <a href="html/libvirt-libvirt-host.html#virConnectGetSysinfo">
        <code>virConnectGetSysinfo</code></a> call can be
        used to see what values are copied), or "sysinfo" (use the values in
        the <a href="#elementsSysinfo">sysinfo</a> element).  If not
        specified, the hypervisor default is used. <span class="since">
        Since 0.8.7</span>
      </dd>
  </dl>
      <p>Up till here the BIOS/UEFI configuration knobs are generic enough to
      be implemented by majority (if not all) firmwares out there. However,
      from now on not every single setting makes sense to all firmwares. For
      instance, <code>rebootTimeout</code> doesn't make sense for UEFI,
      <code>useserial</code> might not be usable with a BIOS firmware that
      doesn't produce any output onto serial line, etc. Moreover, firmwares
      don't usually export their capabilities for libvirt (or users) to check.
      And the set of their capabilities can change with every new release.
      Hence users are advised to try the settings they use before relying on
      them in production.</p>
  <dl>
202 203 204 205 206
      <dt><code>bootmenu</code></dt>
      <dd> Whether or not to enable an interactive boot menu prompt on guest
      startup. The <code>enable</code> attribute can be either "yes" or "no".
      If not specified, the hypervisor default is used. <span class="since">
      Since 0.8.3</span>
207 208
      Additional attribute <code>timeout</code> takes the number of milliseconds
      the boot menu should wait until it times out.  Allowed values are numbers
209 210
      in range [0, 65535] inclusive and it is ignored unless <code>enable</code>
      is set to "yes". <span class="since">Since 1.2.8</span>
211
      </dd>
M
Michal Privoznik 已提交
212 213 214 215 216 217
      <dt><code>bios</code></dt>
      <dd>This element has attribute <code>useserial</code> with possible
        values <code>yes</code> or <code>no</code>. It enables or disables
        Serial Graphics Adapter which allows users to see BIOS messages
        on a serial port. Therefore, one needs to have
        <a href="#elementCharSerial">serial port</a> defined.
218 219 220 221 222 223 224
        <span class="since">Since 0.9.4</span>.
        <span class="since">Since 0.10.2 (QEMU only)</span> there is
        another attribute, <code>rebootTimeout</code> that controls
        whether and after how long the guest should start booting
        again in case the boot fails (according to BIOS). The value is
        in milliseconds with maximum of <code>65535</code> and special
        value <code>-1</code> disables the reboot.
225
      </dd>
D
Daniel P. Berrange 已提交
226 227 228 229 230 231 232
    </dl>

    <h4><a name="elementsOSBootloader">Host bootloader</a></h4>

    <p>
      Hypervisors employing paravirtualization do not usually emulate
      a BIOS, and instead the host is responsible to kicking off the
A
Atsushi SAKAI 已提交
233
      operating system boot. This may use a pseudo-bootloader in the
D
Daniel P. Berrange 已提交
234
      host to provide an interface to choose a kernel for the guest.
235 236 237
      An example is <code>pygrub</code> with Xen. The Bhyve hypervisor
      also uses a host bootloader, either <code>bhyveload</code> or
      <code>grub-bhyve</code>.
D
Daniel P. Berrange 已提交
238 239
    </p>

240 241 242 243 244
<pre>
  ...
  &lt;bootloader&gt;/usr/bin/pygrub&lt;/bootloader&gt;
  &lt;bootloader_args&gt;--append single&lt;/bootloader_args&gt;
  ...</pre>
D
Daniel P. Berrange 已提交
245 246 247 248

    <dl>
      <dt><code>bootloader</code></dt>
      <dd>The content of the <code>bootloader</code> element provides
M
Matthew Booth 已提交
249 250 251 252
        a fully qualified path to the bootloader executable in the
        host OS. This bootloader will be run to choose which kernel
        to boot. The required output of the bootloader is dependent
        on the hypervisor in use. <span class="since">Since 0.1.0</span></dd>
D
Daniel P. Berrange 已提交
253 254
      <dt><code>bootloader_args</code></dt>
      <dd>The optional <code>bootloader_args</code> element allows
M
Matthew Booth 已提交
255 256 257
        command line arguments to be passed to the bootloader.
        <span class="since">Since 0.2.3</span>
        </dd>
D
Daniel P. Berrange 已提交
258 259 260 261 262 263 264 265 266 267 268 269

    </dl>

    <h4><a name="elementsOSKernel">Direct kernel boot</a></h4>

    <p>
      When installing a new guest OS it is often useful to boot directly
      from a kernel and initrd stored in the host OS, allowing command
      line arguments to be passed directly to the installer. This capability
      is usually available for both para and full virtualized guests.
    </p>

270 271 272 273 274 275 276 277
<pre>
  ...
  &lt;os&gt;
    &lt;type&gt;hvm&lt;/type&gt;
    &lt;loader&gt;/usr/lib/xen/boot/hvmloader&lt;/loader&gt;
    &lt;kernel&gt;/root/f8-i386-vmlinuz&lt;/kernel&gt;
    &lt;initrd&gt;/root/f8-i386-initrd&lt;/initrd&gt;
    &lt;cmdline&gt;console=ttyS0 ks=http://example.com/f8-i386/os/&lt;/cmdline&gt;
278
    &lt;dtb&gt;/root/ppc.dtb&lt;/dtb&gt;
279 280
  &lt;/os&gt;
  ...</pre>
D
Daniel P. Berrange 已提交
281 282 283 284

    <dl>
      <dt><code>type</code></dt>
      <dd>This element has the same semantics as described earlier in the
M
Matthew Booth 已提交
285
        <a href="#elementsOSBIOS">BIOS boot section</a></dd>
D
Daniel Veillard 已提交
286
      <dt><code>loader</code></dt>
D
Daniel P. Berrange 已提交
287
      <dd>This element has the same semantics as described earlier in the
M
Matthew Booth 已提交
288
        <a href="#elementsOSBIOS">BIOS boot section</a></dd>
D
Daniel P. Berrange 已提交
289 290
      <dt><code>kernel</code></dt>
      <dd>The contents of this element specify the fully-qualified path
M
Matthew Booth 已提交
291
        to the kernel image in the host OS.</dd>
D
Daniel P. Berrange 已提交
292 293
      <dt><code>initrd</code></dt>
      <dd>The contents of this element specify the fully-qualified path
M
Matthew Booth 已提交
294
        to the (optional) ramdisk image in the host OS.</dd>
D
Daniel P. Berrange 已提交
295 296
      <dt><code>cmdline</code></dt>
      <dd>The contents of this element specify arguments to be passed to
297
        the kernel (or installer) at boot time. This is often used to
M
Matthew Booth 已提交
298 299
        specify an alternate primary console (eg serial port), or the
        installation media source / kickstart file</dd>
300 301 302 303
      <dt><code>dtb</code></dt>
      <dd>The contents of this element specify the fully-qualified path
        to the (optional) device tree binary (dtb) image in the host OS.
        <span class="since">Since 1.0.4</span></dd>
D
Daniel P. Berrange 已提交
304 305
    </dl>

306
    <h4><a name="elementsOSContainer">Container boot</a></h4>
307 308 309 310 311 312 313 314

    <p>
      When booting a domain using container based virtualization, instead
      of a kernel / boot image, a path to the init binary is required, using
      the <code>init</code> element. By default this will be launched with
      no arguments. To specify the initial argv, use the <code>initarg</code>
      element, repeated as many time as is required. The <code>cmdline</code>
      element, if set will be used to provide an equivalent to <code>/proc/cmdline</code>
C
Chen Hanxiao 已提交
315
      but will not affect init argv.
316 317 318 319 320 321 322 323 324 325 326 327
    </p>

    <pre>
  &lt;os&gt;
    &lt;type arch='x86_64'&gt;exe&lt;/type&gt;
    &lt;init&gt;/bin/systemd&lt;/init&gt;
    &lt;initarg&gt;--unit&lt;/initarg&gt;
    &lt;initarg&gt;emergency.service&lt;/initarg&gt;
  &lt;/os&gt;
    </pre>


328
    <p>
329 330
      If you want to enable user namespace, set the <code>idmap</code> element.
      The <code>uid</code> and <code>gid</code> elements have three attributes:
331 332 333 334
    </p>

    <dl>
      <dt><code>start</code></dt>
335
      <dd>First user ID in container. It must be '0'.</dd>
336
      <dt><code>target</code></dt>
337 338
      <dd>The first user ID in container will be mapped to this target user
          ID in host.</dd>
339
      <dt><code>count</code></dt>
340
      <dd>How many users in container are allowed to map to host's user.</dd>
341 342 343 344 345 346 347 348 349 350
    </dl>

    <pre>
  &lt;idmap&gt;
    &lt;uid start='0' target='1000' count='10'/&gt;
    &lt;gid start='0' target='1000' count='10'/&gt;
  &lt;/idmap&gt;
    </pre>


351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373
    <h3><a name="elementsSysinfo">SMBIOS System Information</a></h3>

    <p>
      Some hypervisors allow control over what system information is
      presented to the guest (for example, SMBIOS fields can be
      populated by a hypervisor and inspected via
      the <code>dmidecode</code> command in the guest).  The
      optional <code>sysinfo</code> element covers all such categories
      of information. <span class="since">Since 0.8.7</span>
    </p>

<pre>
  ...
  &lt;os&gt;
    &lt;smbios mode='sysinfo'/&gt;
    ...
  &lt;/os&gt;
  &lt;sysinfo type='smbios'&gt;
    &lt;bios&gt;
      &lt;entry name='vendor'&gt;LENOVO&lt;/entry&gt;
    &lt;/bios&gt;
    &lt;system&gt;
      &lt;entry name='manufacturer'&gt;Fedora&lt;/entry&gt;
374 375
      &lt;entry name='product'&gt;Virt-Manager&lt;/entry&gt;
      &lt;entry name='version'&gt;0.9.4&lt;/entry&gt;
376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398
    &lt;/system&gt;
  &lt;/sysinfo&gt;
  ...</pre>

    <p>
      The <code>sysinfo</code> element has a mandatory
      attribute <code>type</code> that determine the layout of
      sub-elements, with supported values of:
    </p>

    <dl>
      <dt><code>smbios</code></dt>
      <dd>Sub-elements call out specific SMBIOS values, which will
      affect the guest if used in conjunction with
      the <code>smbios</code> sub-element of
      the <a href="#elementsOS"><code>os</code></a> element.  Each
      sub-element of <code>sysinfo</code> names a SMBIOS block, and
      within those elements can be a list of <code>entry</code>
      elements that describe a field within the block.  The following
      blocks and entries are recognized:
        <dl>
          <dt><code>bios</code></dt>
          <dd>
399 400 401 402 403 404 405 406 407 408 409 410 411 412 413
            This is block 0 of SMBIOS, with entry names drawn from:
            <dl>
               <dt><code>vendor</code></dt>
               <dd>BIOS Vendor's Name</dd>
               <dt><code>version</code></dt>
               <dd>BIOS Version</dd>
               <dt><code>date</code></dt>
               <dd>BIOS release date. If supplied, is in either mm/dd/yy or
                   mm/dd/yyyy format. If the year portion of the string is
                   two digits, the year is assumed to be 19yy.</dd>
               <dt><code>release</code></dt>
               <dd>System BIOS Major and Minor release number values
                   concatenated together as one string separated by
                   a period, for example, 10.22.</dd>
           </dl>
414 415 416
          </dd>
          <dt><code>system</code></dt>
          <dd>
417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441
            This is block 1 of SMBIOS, with entry names drawn from:
            <dl>
                <dt><code>manufacturer</code></dt>
                <dd>Manufacturer of BIOS</dd>
                <dt><code>product</code></dt>
                <dd>Product Name</dd>
                <dt><code>version</code></dt>
                <dd>Version of the product</dd>
                <dt><code>serial</code></dt>
                <dd>Serial number</dd>
                <dt><code>uuid</code></dt>
                <dd>Universal Unique ID number. If this entry is provided
                alongside a top-level
                <a href="#elementsMetadata"><code>uuid</code></a> element,
                then the two values must match.</dd>
                <dt><code>sku</code></dt>
                <dd>SKU number to identify a particular configuration.</dd>
                <dt><code>family</code></dt>
                <dd>Identify the family a particular computer belongs to.</dd>
            </dl>
            NB: Incorrectly supplied entries in either the <code>bios</code>
            or <code>system</code> blocks will be ignored without error.
            Other than <code>uuid</code> validation and <code>date</code>
            format checking, all values are passed as strings to the
            hypervisor driver.
442 443 444 445 446
          </dd>
        </dl>
      </dd>
    </dl>

447
    <h3><a name="elementsCPUAllocation">CPU Allocation</a></h3>
D
Daniel P. Berrange 已提交
448

449
<pre>
450
&lt;domain&gt;
451
  ...
O
Osier Yang 已提交
452
  &lt;vcpu placement='static' cpuset="1-4,^3,6" current="1"&gt;2&lt;/vcpu&gt;
453 454 455
  ...
&lt;/domain&gt;
</pre>
D
Daniel P. Berrange 已提交
456 457 458

    <dl>
      <dt><code>vcpu</code></dt>
459
      <dd>The content of this element defines the maximum number of virtual
E
Eric Blake 已提交
460
        CPUs allocated for the guest OS, which must be between 1 and
461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504
        the maximum supported by the hypervisor.
        <dl>
         <dt><code>cpuset</code></dt>
         <dd>
           The optional attribute <code>cpuset</code> is a comma-separated
           list of physical CPU numbers that domain process and virtual CPUs
           can be pinned to by default. (NB: The pinning policy of domain
           process and virtual CPUs can be specified separately by
           <code>cputune</code>. If the attribute <code>emulatorpin</code>
           of <code>cputune</code> is specified, the <code>cpuset</code>
           specified by <code>vcpu</code> here will be ignored. Similarly,
           for virtual CPUs which have the <code>vcpupin</code> specified,
           the <code>cpuset</code> specified by <code>cpuset</code> here
           will be ignored. For virtual CPUs which don't have
           <code>vcpupin</code> specified, each will be pinned to the physical
           CPUs specified by <code>cpuset</code> here).
           Each element in that list is either a single CPU number,
           a range of CPU numbers, or a caret followed by a CPU number to
           be excluded from a previous range.
           <span class="since">Since 0.4.4</span>
         </dd>
         <dt><code>current</code></dt>
         <dd>
           The optional attribute <code>current</code> can
           be used to specify whether fewer than the maximum number of
           virtual CPUs should be enabled.
           <span class="since">Since 0.8.5</span>
         </dd>
         <dt><code>placement</code></dt>
         <dd>
           The optional attribute <code>placement</code> can be used to
           indicate the CPU placement mode for domain process. The value can
           be either "static" or "auto", but defaults to <code>placement</code>
           of <code>numatune</code> or "static" if <code>cpuset</code> is
           specified. Using "auto" indicates the domain process will be pinned
           to the advisory nodeset from querying numad and the value of
           attribute <code>cpuset</code> will be ignored if it's specified.
           If both <code>cpuset</code> and <code>placement</code> are not
           specified or if <code>placement</code> is "static", but no
           <code>cpuset</code> is specified, the domain process will be
           pinned to all the available physical CPUs.
           <span class="since">Since 0.9.11 (QEMU and KVM only)</span>
         </dd>
        </dl>
E
Eric Blake 已提交
505
      </dd>
506 507
    </dl>

508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528
    <h3><a name="elementsIOThreadsAllocation">IOThreads Allocation</a></h3>
      <p>
        IOThreads are dedicated event loop threads for supported disk
        devices to perform block I/O requests in order to improve
        scalability especially on an SMP host/guest with many LUNs.
        <span class="since">Since 1.2.8 (QEMU only)</span>
      </p>

<pre>
&lt;domain&gt;
  ...
  &lt;iothreads&gt;4&lt;/iothreads&gt;
  ...
&lt;/domain&gt;
</pre>

    <dl>
      <dt><code>iothreads</code></dt>
      <dd>
        The content of this optional element defines the number
        of IOThreads to be assigned to the domain for use by
529 530 531
        virtio-blk-pci and virtio-blk-ccw target storage devices. There
        should be only 1 or 2 IOThreads per host CPU. There may be more
        than one supported device assigned to each IOThread.
532 533
      </dd>
    </dl>
534 535 536 537 538 539 540 541 542 543 544

    <h3><a name="elementsCPUTuning">CPU Tuning</a></h3>

<pre>
&lt;domain&gt;
  ...
  &lt;cputune&gt;
    &lt;vcpupin vcpu="0" cpuset="1-4,^2"/&gt;
    &lt;vcpupin vcpu="1" cpuset="0,1"/&gt;
    &lt;vcpupin vcpu="2" cpuset="2,3"/&gt;
    &lt;vcpupin vcpu="3" cpuset="0,4"/&gt;
J
Jiri Denemark 已提交
545
    &lt;emulatorpin cpuset="1-3"/&gt;
546 547
    &lt;iothreadpin iothread="1" cpuset="5,6"/&gt;
    &lt;iothreadpin iothread="2" cpuset="7,8"/&gt;
548 549 550
    &lt;shares&gt;2048&lt;/shares&gt;
    &lt;period&gt;1000000&lt;/period&gt;
    &lt;quota&gt;-1&lt;/quota&gt;
551 552
    &lt;emulator_period&gt;1000000&lt;/emulator_period&gt;
    &lt;emulator_quota&gt;-1&lt;/emulator_quota&gt;
553 554 555 556 557 558
  &lt;/cputune&gt;
  ...
&lt;/domain&gt;
</pre>

    <dl>
559
      <dt><code>cputune</code></dt>
560 561 562 563 564
      <dd>
         The optional <code>cputune</code> element provides details
         regarding the cpu tunable parameters for the domain.
         <span class="since">Since 0.9.0</span>
      </dd>
565
      <dt><code>vcpupin</code></dt>
566
      <dd>
567
        The optional <code>vcpupin</code> element specifies which of host's
568 569 570 571 572 573 574
        physical CPUs the domain VCPU will be pinned to. If this is omitted,
        and attribute <code>cpuset</code> of element <code>vcpu</code> is
        not specified, the vCPU is pinned to all the physical CPUs by default.
        It contains two required attributes, the attribute <code>vcpu</code>
        specifies vcpu id, and the attribute <code>cpuset</code> is same as
        attribute <code>cpuset</code> of element <code>vcpu</code>.
        (NB: Only qemu driver support)
575 576
        <span class="since">Since 0.9.0</span>
       </dd>
T
Tang Chen 已提交
577 578 579 580
       <dt><code>emulatorpin</code></dt>
       <dd>
         The optional <code>emulatorpin</code> element specifies which of host
         physical CPUs the "emulator", a subset of a domain not including vcpu,
581 582 583 584 585 586 587
         will be pinned to. If this is omitted, and attribute
         <code>cpuset</code> of element <code>vcpu</code> is not specified,
         "emulator" is pinned to all the physical CPUs by default. It contains
         one required attribute <code>cpuset</code> specifying which physical
         CPUs to pin to. NB, <code>emulatorpin</code> is not allowed if
         attribute <code>placement</code> of element <code>vcpu</code> is
         "auto".
T
Tang Chen 已提交
588
       </dd>
589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604
       <dt><code>iothreadpin</code></dt>
       <dd>
         The optional <code>iothreadpin</code> element specifies which of host
         physical CPUs the IOThreads will be pinned to. If this is omitted
         and attribute <code>cpuset</code> of element <code>vcpu</code> is
         not specified, the IOThreads are pinned to all the physical CPUs
         by default. There are two required attributes, the attribute
         <code>iothread</code> specifies the IOThread id and the attribute
         <code>cpuset</code> specifying which physical CPUs to pin to. The
         <code>iothread</code> value begins at "1" through the number of
          <a href="#elementsIOThreadsAllocation"><code>iothreads</code></a>
         allocated to the domain. A value of "0" is not permitted.
         NB, <code>iothreadpin</code> is not allowed if attribute
         <code>placement</code> of element <code>vcpu</code> is "auto".
        <span class="since">Since 1.2.9</span>
       </dd>
605
      <dt><code>shares</code></dt>
606 607
      <dd>
        The optional <code>shares</code> element specifies the proportional
608
        weighted share for the domain. If this is omitted, it defaults to
E
Eric Blake 已提交
609 610 611
        the OS provided defaults. NB, There is no unit for the value,
        it's a relative measure based on the setting of other VM,
        e.g. A VM configured with value
612 613 614
        2048 will get twice as much CPU time as a VM configured with value 1024.
        <span class="since">Since 0.9.0</span>
      </dd>
615 616 617 618 619 620
      <dt><code>period</code></dt>
      <dd>
        The optional <code>period</code> element specifies the enforcement
        interval(unit: microseconds). Within <code>period</code>, each vcpu of
        the domain will not be allowed to consume more than <code>quota</code>
        worth of runtime. The value should be in range [1000, 1000000]. A period
621 622 623
        with value 0 means no value.
        <span class="since">Only QEMU driver support since 0.9.4, LXC since
        0.9.10</span>
624 625 626 627 628 629 630 631 632
      </dd>
      <dt><code>quota</code></dt>
      <dd>
        The optional <code>quota</code> element specifies the maximum allowed
        bandwidth(unit: microseconds). A domain with <code>quota</code> as any
        negative value indicates that the domain has infinite bandwidth, which
        means that it is not bandwidth controlled. The value should be in range
        [1000, 18446744073709551] or less than 0. A quota with value 0 means no
        value. You can use this feature to ensure that all vcpus run at the same
633 634 635
        speed.
        <span class="since">Only QEMU driver support since 0.9.4, LXC since
        0.9.10</span>
636
      </dd>
637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658

      <dt><code>emulator_period</code></dt>
      <dd>
        The optional <code>emulator_period</code> element specifies the enforcement
        interval(unit: microseconds). Within <code>emulator_period</code>, emulator
        threads(those excluding vcpus) of the domain will not be allowed to consume
        more than <code>emulator_quota</code> worth of runtime. The value should be
        in range [1000, 1000000]. A period with value 0 means no value.
        <span class="since">Only QEMU driver support since 0.10.0</span>
      </dd>
      <dt><code>emulator_quota</code></dt>
      <dd>
        The optional <code>emulator_quota</code> element specifies the maximum
        allowed bandwidth(unit: microseconds) for domain's emulator threads(those
        excluding vcpus). A domain with <code>emulator_quota</code> as any negative
        value indicates that the domain has infinite bandwidth for emulator threads
        (those excluding vcpus), which means that it is not bandwidth controlled.
        The value should be in range [1000, 18446744073709551] or less than 0. A
        quota with value 0 means no value.
        <span class="since">Only QEMU driver support since 0.10.0</span>
      </dd>

659 660 661 662 663 664 665 666
    </dl>


    <h3><a name="elementsMemoryAllocation">Memory Allocation</a></h3>

<pre>
&lt;domain&gt;
  ...
E
Eric Blake 已提交
667 668
  &lt;memory unit='KiB'&gt;524288&lt;/memory&gt;
  &lt;currentMemory unit='KiB'&gt;524288&lt;/currentMemory&gt;
669 670 671 672 673 674 675
  ...
&lt;/domain&gt;
</pre>

    <dl>
      <dt><code>memory</code></dt>
      <dd>The maximum allocation of memory for the guest at boot time.
E
Eric Blake 已提交
676
        The units for this value are determined by the optional
677
        attribute <code>unit</code>, which defaults to "KiB"
E
Eric Blake 已提交
678 679 680 681 682 683 684 685 686 687 688 689 690
        (kibibytes, 2<sup>10</sup> or blocks of 1024 bytes).  Valid
        units are "b" or "bytes" for bytes, "KB" for kilobytes
        (10<sup>3</sup> or 1,000 bytes), "k" or "KiB" for kibibytes
        (1024 bytes), "MB" for megabytes (10<sup>6</sup> or 1,000,000
        bytes), "M" or "MiB" for mebibytes (2<sup>20</sup> or
        1,048,576 bytes), "GB" for gigabytes (10<sup>9</sup> or
        1,000,000,000 bytes), "G" or "GiB" for gibibytes
        (2<sup>30</sup> or 1,073,741,824 bytes), "TB" for terabytes
        (10<sup>12</sup> or 1,000,000,000,000 bytes), or "T" or "TiB"
        for tebibytes (2<sup>40</sup> or 1,099,511,627,776 bytes).
        However, the value will be rounded up to the nearest kibibyte
        by libvirt, and may be further rounded to the granularity
        supported by the hypervisor.  Some hypervisors also enforce a
691 692 693 694 695 696 697 698 699
        minimum, such as 4000KiB.

        In the case of crash, optional attribute <code>dumpCore</code>
        can be used to control whether the guest memory should be
        included in the generated coredump or not (values "on", "off").

        <span class='since'><code>unit</code> since 0.9.11</span>,
        <span class='since'><code>dumpCore</code> since 0.10.2
        (QEMU only)</span></dd>
700 701 702 703
      <dt><code>currentMemory</code></dt>
      <dd>The actual allocation of memory for the guest. This value can
        be less than the maximum allocation, to allow for ballooning
        up the guests memory on the fly. If this is omitted, it defaults
E
Eric Blake 已提交
704 705 706
        to the same value as the <code>memory</code> element.
        The <code>unit</code> attribute behaves the same as
        for <code>memory</code>.</dd>
707 708 709 710 711 712 713 714 715
    </dl>


    <h3><a name="elementsMemoryBacking">Memory Backing</a></h3>

<pre>
&lt;domain&gt;
  ...
  &lt;memoryBacking&gt;
716 717 718
    &lt;hugepages&gt;
      &lt;page size="1" unit="G" nodeset="0-3,5"/&gt;
      &lt;page size="2" unit="M" nodeset="4"/&gt;
719
    &lt;/hugepages&gt;
720
    &lt;nosharepages/&gt;
721
    &lt;locked/&gt;
722 723 724 725 726
  &lt;/memoryBacking&gt;
  ...
&lt;/domain&gt;
</pre>

727 728 729 730
    <p>The optional <code>memoryBacking</code> element may contain several
      elements that influence how virtual memory pages are backed by host
      pages.</p>

731
    <dl>
732 733
      <dt><code>hugepages</code></dt>
      <dd>This tells the hypervisor that the guest should have its memory
734 735 736 737 738 739 740 741 742 743 744 745 746
      allocated using hugepages instead of the normal native page size.
      <span class='since'>Since 1.2.5</span> it's possible to set hugepages
      more specifically per numa node. The <code>page</code> element is
      introduced. It has one compulsory attribute <code>size</code> which
      specifies which hugepages should be used (especially useful on systems
      supporting hugepages of different sizes). The default unit for the
      <code>size</code> attribute is kilobytes (multiplier of 1024). If you
      want to use different unit, use optional <code>unit</code> attribute.
      For systems with NUMA, the optional <code>nodeset</code> attribute may
      come handy as it ties given guest's NUMA nodes to certain hugepage
      sizes. From the example snippet, one gigabyte hugepages are used for
      every NUMA node except node number four. For the correct syntax see
      <a href="#elementsNUMATuning">this</a>.</dd>
747 748 749 750 751 752
      <dt><code>nosharepages</code></dt>
      <dd>Instructs hypervisor to disable shared pages (memory merge, KSM) for
        this domain. <span class="since">Since 1.0.6</span></dd>
      <dt><code>locked</code></dt>
      <dd>When set and supported by the hypervisor, memory pages belonging
        to the domain will be locked in host's memory and the host will not
753
        be allowed to swap them out. For QEMU/KVM this requires
E
Eric Blake 已提交
754
        <code>hard_limit</code> <a href="#elementsMemoryTuning">memory tuning</a>
755 756
        element to be used and set to the maximum memory configured for the
        domain plus any memory consumed by the QEMU process itself.
757
        <span class="since">Since 1.0.6</span></dd>
758 759 760 761 762 763 764 765 766
    </dl>


    <h3><a name="elementsMemoryTuning">Memory Tuning</a></h3>

<pre>
&lt;domain&gt;
  ...
  &lt;memtune&gt;
E
Eric Blake 已提交
767 768 769 770
    &lt;hard_limit unit='G'&gt;1&lt;/hard_limit&gt;
    &lt;soft_limit unit='M'&gt;128&lt;/soft_limit&gt;
    &lt;swap_hard_limit unit='G'&gt;2&lt;/swap_hard_limit&gt;
    &lt;min_guarantee unit='bytes'&gt;67108864&lt;/min_guarantee&gt;
771 772 773 774 775 776 777 778 779 780 781 782 783
  &lt;/memtune&gt;
  ...
&lt;/domain&gt;
</pre>

    <dl>
      <dt><code>memtune</code></dt>
      <dd> The optional <code>memtune</code> element provides details
        regarding the memory tunable parameters for the domain. If this is
        omitted, it defaults to the OS provided defaults. For QEMU/KVM, the
        parameters are applied to the QEMU process as a whole. Thus, when
        counting them, one needs to add up guest RAM, guest video RAM, and
        some memory overhead of QEMU itself. The last piece is hard to
E
Eric Blake 已提交
784 785 786 787 788 789 790
        determine so one needs guess and try.  For each tunable, it
        is possible to designate which unit the number is in on
        input, using the same values as
        for <code>&lt;memory&gt;</code>.  For backwards
        compatibility, output is always in
        KiB.  <span class='since'><code>unit</code>
        since 0.9.11</span></dd>
791 792
      <dt><code>hard_limit</code></dt>
      <dd> The optional <code>hard_limit</code> element is the maximum memory
793
        the guest can use. The units for this value are kibibytes (i.e. blocks
794
        of 1024 bytes). <strong>However, users of QEMU and KVM are strongly
M
Michal Privoznik 已提交
795 796 797
        advised not to set this limit as domain may get killed by the kernel
        if the guess is too low. To determine the memory needed for a process
        to run is an
798 799
        <a href="http://en.wikipedia.org/wiki/Undecidable_problem">
        undecidable problem</a>.</strong></dd>
800 801 802
      <dt><code>soft_limit</code></dt>
      <dd> The optional <code>soft_limit</code> element is the memory limit to
        enforce during memory contention. The units for this value are
803
        kibibytes (i.e. blocks of 1024 bytes)</dd>
804 805 806
      <dt><code>swap_hard_limit</code></dt>
      <dd> The optional <code>swap_hard_limit</code> element is the maximum
        memory plus swap the guest can use. The units for this value are
807
        kibibytes (i.e. blocks of 1024 bytes). This has to be more than
808 809 810 811
        hard_limit value provided</dd>
      <dt><code>min_guarantee</code></dt>
      <dd> The optional <code>min_guarantee</code> element is the guaranteed
        minimum memory allocation for the guest. The units for this value are
812 813
        kibibytes (i.e. blocks of 1024 bytes). This element is only supported
        by VMware ESX and OpenVZ drivers.</dd>
814 815 816 817 818 819 820 821 822 823
    </dl>


    <h3><a name="elementsNUMATuning">NUMA Node Tuning</a></h3>

<pre>
&lt;domain&gt;
  ...
  &lt;numatune&gt;
    &lt;memory mode="strict" nodeset="1-4,^3"/&gt;
824 825
    &lt;memnode cellid="0" mode="strict" nodeset="1"/&gt;
    &lt;memnode cellid="2" mode="preferred" nodeset="2"/&gt;
826 827 828 829 830 831
  &lt;/numatune&gt;
  ...
&lt;/domain&gt;
</pre>

    <dl>
832 833 834 835 836 837
      <dt><code>numatune</code></dt>
      <dd>
        The optional <code>numatune</code> element provides details of
        how to tune the performance of a NUMA host via controlling NUMA policy
        for domain process. NB, only supported by QEMU driver.
        <span class='since'>Since 0.9.3</span>
838
      </dd>
839 840
      <dt><code>memory</code></dt>
      <dd>
O
Osier Yang 已提交
841
        The optional <code>memory</code> element specifies how to allocate memory
842 843 844 845 846 847 848 849 850 851 852 853 854 855 856 857 858 859
        for the domain process on a NUMA host. It contains several optional
        attributes. Attribute <code>mode</code> is either 'interleave',
        'strict', or 'preferred', defaults to 'strict'. Attribute
        <code>nodeset</code> specifies the NUMA nodes, using the same syntax as
        attribute <code>cpuset</code> of element <code>vcpu</code>. Attribute
        <code>placement</code> (<span class='since'>since 0.9.12</span>) can be
        used to indicate the memory placement mode for domain process, its value
        can be either "static" or "auto", defaults to <code>placement</code> of
        <code>vcpu</code>, or "static" if <code>nodeset</code> is specified.
        "auto" indicates the domain process will only allocate memory from the
        advisory nodeset returned from querying numad, and the value of attribute
        <code>nodeset</code> will be ignored if it's specified.

        If <code>placement</code> of <code>vcpu</code> is 'auto', and
        <code>numatune</code> is not specified, a default <code>numatune</code>
        with <code>placement</code> 'auto' and <code>mode</code> 'strict' will
        be added implicitly.

860 861
        <span class='since'>Since 0.9.3</span>
      </dd>
862 863 864 865 866 867 868 869 870 871 872 873 874
      <dt><code>memnode</code></dt>
      <dd>
        Optional <code>memnode</code> elements can specify memory allocation
        policies per each guest NUMA node.  For those nodes having no
        corresponding <code>memnode</code> element, the default from
        element <code>memory</code> will be used.  Attribute <code>cellid</code>
        addresses guest NUMA node for which the settings are applied.
        Attributes <code>mode</code> and <code>nodeset</code> have the same
        meaning and syntax as in <code>memory</code> element.

        This setting is not compatible with automatic placement.
        <span class='since'>QEMU Since 1.2.7</span>
      </dd>
D
Daniel P. Berrange 已提交
875 876
    </dl>

877 878 879 880 881 882 883

    <h3><a name="elementsBlockTuning">Block I/O Tuning</a></h3>
<pre>
&lt;domain&gt;
  ...
  &lt;blkiotune&gt;
    &lt;weight&gt;800&lt;/weight&gt;
884 885 886 887 888 889 890 891
    &lt;device&gt;
      &lt;path&gt;/dev/sda&lt;/path&gt;
      &lt;weight&gt;1000&lt;/weight&gt;
    &lt;/device&gt;
    &lt;device&gt;
      &lt;path&gt;/dev/sdb&lt;/path&gt;
      &lt;weight&gt;500&lt;/weight&gt;
    &lt;/device&gt;
892 893 894 895 896 897 898 899 900
  &lt;/blkiotune&gt;
  ...
&lt;/domain&gt;
</pre>

    <dl>
      <dt><code>blkiotune</code></dt>
      <dd> The optional <code>blkiotune</code> element provides the ability
        to tune Blkio cgroup tunable parameters for the domain. If this is
901 902
        omitted, it defaults to the OS provided
        defaults. <span class="since">Since 0.8.8</span></dd>
903
      <dt><code>weight</code></dt>
904 905
      <dd> The optional <code>weight</code> element is the overall I/O
        weight of the guest. The value should be in the range [100,
906 907
        1000]. After kernel 2.6.39, the value could be in the
        range [10, 1000].</dd>
908 909 910 911 912 913 914 915
      <dt><code>device</code></dt>
      <dd>The domain may have multiple <code>device</code> elements
        that further tune the weights for each host block device in
        use by the domain.  Note that
        multiple <a href="#elementsDisks">guest disks</a> can share a
        single host block device, if they are backed by files within
        the same host file system, which is why this tuning parameter
        is at the global domain level rather than associated with each
L
Lei Li 已提交
916 917 918 919 920
        guest disk device (contrast this to
        the <a href="#elementsDisks"><code>&lt;iotune&gt;</code></a>
        element which can apply to an
        individual <code>&lt;disk&gt;</code>).
        Each <code>device</code> element has two
921 922 923
        mandatory sub-elements, <code>path</code> describing the
        absolute path of the device, and <code>weight</code> giving
        the relative weight of that device, in the range [100,
924 925
        1000]. After kernel 2.6.39, the value could be in the
        range [10, 1000].<span class="since">Since 0.9.8</span></dd>
926 927 928
    </dl>


929 930 931 932 933 934 935 936 937 938 939 940 941 942 943 944 945 946 947 948 949 950 951 952 953
    <h3><a name="resPartition">Resource partitioning</a></h3>

    <p>
      Hypervisors may allow for virtual machines to be placed into
      resource partitions, potentially with nesting of said partitions.
      The <code>resource</code> element groups together configuration
      related to resource partitioning. It currently supports a child
      element <code>partition</code> whose content defines the path
      of the resource partition in which to place the domain. If no
      partition is listed, then the domain will be placed in a default
      partition. It is the responsibility of the app/admin to ensure
      that the partition exists prior to starting the guest. Only the
      (hypervisor specific) default partition can be assumed to exist
      by default.
    </p>
<pre>
  ...
  &lt;resource&gt;
    &lt;partition&gt;/virtualmachines/production&lt;/partition&gt;
  &lt;/resource&gt;
  ...
</pre>

    <p>
      Resource partitions are currently supported by the QEMU and
E
Eric Blake 已提交
954
      LXC drivers, which map partition paths to cgroups directories,
955 956 957
      in all mounted controllers. <span class="since">Since 1.0.5</span>
    </p>

958 959 960 961 962 963 964 965
    <h3><a name="elementsCPU">CPU model and topology</a></h3>

    <p>
      Requirements for CPU model, its features and topology can be specified
      using the following collection of elements.
      <span class="since">Since 0.7.5</span>
    </p>

966 967 968
<pre>
  ...
  &lt;cpu match='exact'&gt;
969
    &lt;model fallback='allow'&gt;core2duo&lt;/model&gt;
J
Jiri Denemark 已提交
970
    &lt;vendor&gt;Intel&lt;/vendor&gt;
971 972 973 974
    &lt;topology sockets='1' cores='2' threads='1'/&gt;
    &lt;feature policy='disable' name='lahf_lm'/&gt;
  &lt;/cpu&gt;
  ...</pre>
975

976 977 978 979 980 981 982 983 984
<pre>
  &lt;cpu mode='host-model'&gt;
    &lt;model fallback='forbid'/&gt;
    &lt;topology sockets='1' cores='2' threads='1'/&gt;
  &lt;/cpu&gt;
  ...</pre>

<pre>
  &lt;cpu mode='host-passthrough'/&gt;
985
    &lt;feature policy='disable' name='lahf_lm'/&gt;
986 987
  ...</pre>

988 989 990 991 992 993
    <p>
      In case no restrictions need to be put on CPU model and its features, a
      simpler <code>cpu</code> element can be used.
      <span class="since">Since 0.7.6</span>
    </p>

994 995 996 997 998 999
<pre>
  ...
  &lt;cpu&gt;
    &lt;topology sockets='1' cores='2' threads='1'/&gt;
  &lt;/cpu&gt;
  ...</pre>
1000 1001 1002 1003 1004 1005 1006 1007 1008 1009 1010 1011 1012 1013 1014 1015 1016 1017 1018 1019 1020 1021

    <dl>
      <dt><code>cpu</code></dt>
      <dd>The <code>cpu</code> element is the main container for describing
        guest CPU requirements. Its <code>match</code> attribute specified how
        strictly has the virtual CPU provided to the guest match these
        requirements. <span class="since">Since 0.7.6</span> the
        <code>match</code> attribute can be omitted if <code>topology</code>
        is the only element within <code>cpu</code>. Possible values for the
        <code>match</code> attribute are:

        <dl>
          <dt><code>minimum</code></dt>
          <dd>The specified CPU model and features describes the minimum
            requested CPU.</dd>
          <dt><code>exact</code></dt>
          <dd>The virtual CPU provided to the guest will exactly match the
            specification</dd>
          <dt><code>strict</code></dt>
          <dd>The guest will not be created unless the host CPU does exactly
            match the specification.</dd>
        </dl>
1022

E
Eric Blake 已提交
1023 1024
        <span class="since">Since 0.8.5</span> the <code>match</code>
        attribute can be omitted and will default to <code>exact</code>.
1025 1026 1027 1028 1029 1030 1031 1032 1033 1034 1035 1036 1037 1038 1039 1040 1041 1042

        <span class="since">Since 0.9.10</span>, an optional <code>mode</code>
        attribute may be used to make it easier to configure a guest CPU to be
        as close to host CPU as possible. Possible values for the
        <code>mode</code> attribute are:

        <dl>
          <dt><code>custom</code></dt>
          <dd>In this mode, the <code>cpu</code> element describes the CPU
          that should be presented to the guest. This is the default when no
          <code>mode</code> attribute is specified. This mode makes it so that
          a persistent guest will see the same hardware no matter what host
          the guest is booted on.</dd>
          <dt><code>host-model</code></dt>
          <dd>The <code>host-model</code> mode is essentially a shortcut to
          copying host CPU definition from capabilities XML into domain XML.
          Since the CPU definition is copied just before starting a domain,
          exactly the same XML can be used on different hosts while still
1043 1044 1045 1046 1047 1048 1049 1050 1051
          providing the best guest CPU each host supports. The
          <code>match</code> attribute can't be used in this mode. Specifying
          CPU model is not supported either, but <code>model</code>'s
          <code>fallback</code> attribute may still be used. Using the
          <code>feature</code> element, specific flags may be enabled or
          disabled specifically in addition to the host model. This may be
          used to fine tune features that can be emulated.
          <span class="since">(Since 1.1.1)</span>.
          Libvirt does not model every aspect of each CPU so
1052 1053 1054 1055 1056 1057 1058
          the guest CPU will not match the host CPU exactly. On the other
          hand, the ABI provided to the guest is reproducible. During
          migration, complete CPU model definition is transferred to the
          destination host so the migrated guest will see exactly the same CPU
          model even if the destination host contains more capable CPUs for
          the running instance of the guest; but shutting down and restarting
          the guest may present different hardware to the guest according to
1059 1060 1061 1062 1063 1064 1065 1066 1067
          the capabilities of the new host. <strong>Beware</strong>, due to the
          way libvirt detects host CPU and due to the fact libvirt does not
          talk to QEMU/KVM when creating the CPU model, CPU configuration
          created using <code>host-model</code> may not work as expected. The
          guest CPU may differ from the configuration and it may also confuse
          guest OS by using a combination of CPU features and other parameters
          (such as CPUID level) that don't work. Until these issues are fixed,
          it's a good idea to avoid using <code>host-model</code> and use
          <code>custom</code> mode with just the CPU model from host
1068 1069 1070 1071 1072 1073 1074 1075 1076 1077 1078 1079 1080 1081
          capabilities XML.
          <span class="since">(Since 1.2.11)</span>. PowerISA allows
          processors to run VMs in binary compatibility mode supporting an
          older version of ISA.  Libvirt on PowerPC architecture uses the
          <code>host-model</code> to signify a guest mode CPU running in
          binary compatibility mode. Example:
          When a user needs a power7 VM to run in compatibility mode
          on a Power8 host, this can be described in XML as follows :
<pre>
  &lt;cpu mode='host-model'&gt;
    &lt;model&gt;power7&lt;/model&gt;
  &lt;/cpu&gt;
  ...</pre>
          </dd>
1082 1083 1084 1085 1086
          <dt><code>host-passthrough</code></dt>
          <dd>With this mode, the CPU visible to the guest should be exactly
          the same as the host CPU even in the aspects that libvirt does not
          understand. Though the downside of this mode is that the guest
          environment cannot be reproduced on different hardware. Thus, if you
1087 1088
          hit any bugs, you are on your own. Further details of that CPU can
          be changed using <code>feature</code> elements.</dd>
1089 1090 1091 1092 1093 1094 1095 1096 1097 1098 1099
        </dl>

        In both <code>host-model</code> and <code>host-passthrough</code>
        mode, the real (approximate in <code>host-passthrough</code> mode) CPU
        definition which would be used on current host can be determined by
        specifying <code>VIR_DOMAIN_XML_UPDATE_CPU</code> flag when calling
        <code>virDomainGetXMLDesc</code> API. When running a guest that might
        be prone to operating system reactivation when presented with
        different hardware, and which will be migrated between hosts with
        different capabilities, you can use this output to rewrite XML to the
        <code>custom</code> mode for more robust migration.
1100 1101 1102 1103 1104 1105
      </dd>

      <dt><code>model</code></dt>
      <dd>The content of the <code>model</code> element specifies CPU model
        requested by the guest. The list of available CPU models and their
        definition can be found in <code>cpu_map.xml</code> file installed
1106 1107 1108 1109 1110 1111 1112 1113
        in libvirt's data directory. If a hypervisor is not able to use the
        exact CPU model, libvirt automatically falls back to a closest model
        supported by the hypervisor while maintaining the list of CPU
        features. <span class="since">Since 0.9.10</span>, an optional
        <code>fallback</code> attribute can be used to forbid this behavior,
        in which case an attempt to start a domain requesting an unsupported
        CPU model will fail. Supported values for <code>fallback</code>
        attribute are: <code>allow</code> (this is the default), and
1114
        <code>forbid</code>. The optional <code>vendor_id</code> attribute
1115
        (<span class="since">Since 0.10.0</span>)  can be used to set the
1116 1117 1118
        vendor id seen by the guest. It must be exactly 12 characters long.
        If not set the vendor id of the host is used. Typical possible
        values are "AuthenticAMD" and "GenuineIntel".</dd>
1119

J
Jiri Denemark 已提交
1120 1121 1122 1123 1124 1125 1126
      <dt><code>vendor</code></dt>
      <dd><span class="since">Since 0.8.3</span> the content of the
        <code>vendor</code> element specifies CPU vendor requested by the
        guest. If this element is missing, the guest can be run on a CPU
        matching given features regardless on its vendor. The list of
        supported vendors can be found in <code>cpu_map.xml</code>.</dd>

1127 1128 1129 1130 1131 1132 1133 1134 1135 1136 1137 1138 1139 1140 1141 1142 1143 1144 1145 1146 1147 1148 1149 1150 1151 1152 1153 1154 1155 1156 1157
      <dt><code>topology</code></dt>
      <dd>The <code>topology</code> element specifies requested topology of
        virtual CPU provided to the guest. Three non-zero values have to be
        given for <code>sockets</code>, <code>cores</code>, and
        <code>threads</code>: total number of CPU sockets, number of cores per
        socket, and number of threads per core, respectively.</dd>

      <dt><code>feature</code></dt>
      <dd>The <code>cpu</code> element can contain zero or more
        <code>elements</code> used to fine-tune features provided by the
        selected CPU model. The list of known feature names can be found in
        the same file as CPU models. The meaning of each <code>feature</code>
        element depends on its <code>policy</code> attribute, which has to be
        set to one of the following values:

        <dl>
          <dt><code>force</code></dt>
          <dd>The virtual CPU will claim the feature is supported regardless
            of it being supported by host CPU.</dd>
          <dt><code>require</code></dt>
          <dd>Guest creation will fail unless the feature is supported by host
            CPU.</dd>
          <dt><code>optional</code></dt>
          <dd>The feature will be supported by virtual CPU if and only if it
            is supported by host CPU.</dd>
          <dt><code>disable</code></dt>
          <dd>The feature will not be supported by virtual CPU.</dd>
          <dt><code>forbid</code></dt>
          <dd>Guest creation will fail if the feature is supported by host
            CPU.</dd>
        </dl>
1158

E
Eric Blake 已提交
1159 1160
        <span class="since">Since 0.8.5</span> the <code>policy</code>
        attribute can be omitted and will default to <code>require</code>.
1161 1162 1163
      </dd>
    </dl>

1164
    <p>
1165
      Guest NUMA topology can be specified using the <code>numa</code> element.
1166 1167 1168 1169 1170 1171 1172 1173
      <span class="since">Since 0.9.8</span>
    </p>

<pre>
  ...
  &lt;cpu&gt;
    ...
    &lt;numa&gt;
1174 1175
      &lt;cell id='0' cpus='0-3' memory='512000' unit='KiB'/&gt;
      &lt;cell id='1' cpus='4-7' memory='512000' unit='KiB' memAccess='shared'/&gt;
1176 1177 1178 1179 1180 1181 1182
    &lt;/numa&gt;
    ...
  &lt;/cpu&gt;
  ...</pre>

    <p>
      Each <code>cell</code> element specifies a NUMA cell or a NUMA node.
1183 1184 1185
      <code>cpus</code> specifies the CPU or range of CPUs that are
      part of the node. <code>memory</code> specifies the node memory
      in kibibytes (i.e. blocks of 1024 bytes).
1186 1187 1188
      <span class="since">Since 1.2.11</span> one can use an additional <a
          href="#elementsMemoryAllocation"><code>unit</code></a> attribute to
      define units in which <code>memory</code> is specified.
1189 1190 1191 1192 1193 1194
      <span class="since">Since 1.2.7</span> all cells should
      have <code>id</code> attribute in case referring to some cell is
      necessary in the code, otherwise the cells are
      assigned <code>id</code>s in the increasing order starting from
      0.  Mixing cells with and without the <code>id</code> attribute
      is not recommended as it may result in unwanted behaviour.
1195 1196 1197 1198 1199

      <span class='since'>Since 1.2.9</span> the optional attribute
      <code>memAccess</code> can control whether the memory is to be
      mapped as "shared" or "private".  This is valid only for
      hugepages-backed memory.
1200 1201 1202 1203 1204 1205
    </p>

    <p>
      This guest NUMA specification is currently available only for QEMU/KVM.
    </p>

1206
    <h3><a name="elementsEvents">Events configuration</a></h3>
D
Daniel P. Berrange 已提交
1207 1208

    <p>
A
Atsushi SAKAI 已提交
1209
      It is sometimes necessary to override the default actions taken
1210 1211
      on various events. Not all hypervisors support all events and actions.
      The actions may be taken as a result of calls to libvirt APIs
1212 1213 1214 1215 1216 1217 1218 1219 1220 1221
      <a href="html/libvirt-libvirt-domain.html#virDomainReboot">
        <code>virDomainReboot</code>
      </a>,
      <a href="html/libvirt-libvirt-domain.html#virDomainShutdown">
        <code>virDomainShutdown</code>
      </a>,
      or
      <a href="html/libvirt-libvirt-domain.html#virDomainShutdownFlags">
        <code>virDomainShutdownFlags</code>
      </a>.
1222 1223
      Using <code>virsh reboot</code> or <code>virsh shutdown</code> would
      also trigger the event.
D
Daniel P. Berrange 已提交
1224 1225
    </p>

1226 1227 1228 1229 1230
<pre>
  ...
  &lt;on_poweroff&gt;destroy&lt;/on_poweroff&gt;
  &lt;on_reboot&gt;restart&lt;/on_reboot&gt;
  &lt;on_crash&gt;restart&lt;/on_crash&gt;
1231
  &lt;on_lockfailure&gt;poweroff&lt;/on_lockfailure&gt;
1232
  ...</pre>
D
Daniel P. Berrange 已提交
1233

1234 1235 1236 1237 1238 1239 1240
    <p>
      The following collections of elements allow the actions to be
      specified when a guest OS triggers a lifecycle operation. A
      common use case is to force a reboot to be treated as a poweroff
      when doing the initial OS installation. This allows the VM to be
      re-configured for the first post-install bootup.
    </p>
D
Daniel P. Berrange 已提交
1241 1242 1243
    <dl>
      <dt><code>on_poweroff</code></dt>
      <dd>The content of this element specifies the action to take when
M
Matthew Booth 已提交
1244
        the guest requests a poweroff.</dd>
D
Daniel Veillard 已提交
1245
      <dt><code>on_reboot</code></dt>
D
Daniel P. Berrange 已提交
1246
      <dd>The content of this element specifies the action to take when
M
Matthew Booth 已提交
1247
        the guest requests a reboot.</dd>
D
Daniel Veillard 已提交
1248
      <dt><code>on_crash</code></dt>
D
Daniel P. Berrange 已提交
1249
      <dd>The content of this element specifies the action to take when
M
Matthew Booth 已提交
1250
        the guest crashes.</dd>
D
Daniel P. Berrange 已提交
1251 1252 1253 1254 1255 1256 1257 1258 1259
    </dl>

    <p>
      Each of these states allow for the same four possible actions.
    </p>

    <dl>
      <dt><code>destroy</code></dt>
      <dd>The domain will be terminated completely and all resources
1260
        released.</dd>
D
Daniel P. Berrange 已提交
1261
      <dt><code>restart</code></dt>
1262 1263
      <dd>The domain will be terminated and then restarted with
        the same configuration.</dd>
D
Daniel P. Berrange 已提交
1264
      <dt><code>preserve</code></dt>
1265
      <dd>The domain will be terminated and its resource preserved
M
Matthew Booth 已提交
1266
        to allow analysis.</dd>
D
Daniel P. Berrange 已提交
1267
      <dt><code>rename-restart</code></dt>
1268 1269
      <dd>The domain will be terminated and then restarted with
        a new name.</dd>
D
Daniel P. Berrange 已提交
1270 1271
    </dl>

1272
    <p>
1273 1274 1275 1276 1277 1278 1279 1280 1281 1282
    QEMU/KVM supports the <code>on_poweroff</code> and <code>on_reboot</code>
    events handling the <code>destroy</code> and <code>restart</code> actions.
    The <code>preserve</code> action for an <code>on_reboot</code> event
    is treated as a <code>destroy</code> and the <code>rename-restart</code>
    action for an <code>on_poweroff</code> event is treated as a
    <code>restart</code> event.
    </p>

    <p>
      The <code>on_crash</code> event supports these additional
1283 1284 1285 1286 1287 1288 1289 1290 1291 1292 1293 1294 1295
      actions <span class="since">since 0.8.4</span>.
    </p>

    <dl>
      <dt><code>coredump-destroy</code></dt>
      <dd>The crashed domain's core will be dumped, and then the
        domain will be terminated completely and all resources
        released</dd>
      <dt><code>coredump-restart</code></dt>
      <dd>The crashed domain's core will be dumped, and then the
        domain will be restarted with the same configuration</dd>
    </dl>

1296 1297
    <p>
      The <code>on_lockfailure</code> element (<span class="since">since
1298
      1.0.0</span>) may be used to configure what action should be
1299 1300 1301 1302 1303 1304 1305 1306 1307 1308 1309 1310 1311 1312 1313 1314 1315 1316
      taken when a lock manager loses resource locks. The following
      actions are recognized by libvirt, although not all of them need
      to be supported by individual lock managers. When no action is
      specified, each lock manager will take its default action.
    </p>
    <dl>
      <dt><code>poweroff</code></dt>
      <dd>The domain will be forcefully powered off.</dd>
      <dt><code>restart</code></dt>
      <dd>The domain will be powered off and started up again to
        reacquire its locks.</dd>
      <dt><code>pause</code></dt>
      <dd>The domain will be paused so that it can be manually resumed
        when lock issues are solved.</dd>
      <dt><code>ignore</code></dt>
      <dd>Keep the domain running as if nothing happened.</dd>
    </dl>

1317 1318 1319 1320 1321 1322 1323 1324 1325 1326 1327 1328
    <h3><a name="elementsPowerManagement">Power Management</a></h3>

    <p>
      <span class="since">Since 0.10.2</span> it is possible to
      forcibly enable or disable BIOS advertisements to the guest
      OS. (NB: Only qemu driver support)
    </p>

<pre>
  ...
  &lt;pm&gt;
    &lt;suspend-to-disk enabled='no'/&gt;
1329
    &lt;suspend-to-mem enabled='yes'/&gt;
1330 1331 1332 1333 1334 1335 1336 1337 1338 1339 1340
  &lt;/pm&gt;
  ...</pre>

    <dl>
      <dt><code>pm</code></dt>
      <dd>These elements enable ('yes') or disable ('no') BIOS support
        for S3 (suspend-to-disk) and S4 (suspend-to-mem) ACPI sleep
        states. If nothing is specified, then the hypervisor will be
        left with its default value.</dd>
    </dl>

D
Daniel P. Berrange 已提交
1341 1342 1343 1344 1345 1346 1347
    <h3><a name="elementsFeatures">Hypervisor features</a></h3>

    <p>
      Hypervisors may allow certain CPU / machine features to be
      toggled on/off.
    </p>

1348 1349 1350 1351 1352 1353
<pre>
  ...
  &lt;features&gt;
    &lt;pae/&gt;
    &lt;acpi/&gt;
    &lt;apic/&gt;
J
Jim Fehlig 已提交
1354
    &lt;hap/&gt;
1355
    &lt;privnet/&gt;
1356
    &lt;hyperv&gt;
E
Eric Blake 已提交
1357
      &lt;relaxed state='on'/&gt;
1358
      &lt;vapic state='on'/&gt;
1359
      &lt;spinlocks state='on' retries='4096'/&gt;
1360
    &lt;/hyperv&gt;
1361 1362 1363
    &lt;kvm&gt;
      &lt;hidden state='on'/&gt;
    &lt;/kvm&gt;
1364
    &lt;pvspinlock/&gt;
1365

1366 1367
  &lt;/features&gt;
  ...</pre>
D
Daniel P. Berrange 已提交
1368 1369 1370 1371 1372 1373 1374 1375 1376 1377 1378 1379

    <p>
      All features are listed within the <code>features</code>
      element, omitting a togglable feature tag turns it off.
      The available features can be found by asking
      for the <a href="formatcaps.html">capabilities XML</a>,
      but a common set for fully virtualized domains are:
    </p>

    <dl>
      <dt><code>pae</code></dt>
      <dd>Physical address extension mode allows 32-bit guests
M
Matthew Booth 已提交
1380
        to address more than 4 GB of memory.</dd>
D
Daniel P. Berrange 已提交
1381 1382
      <dt><code>acpi</code></dt>
      <dd>ACPI is useful for power management, for example, with
M
Matthew Booth 已提交
1383
        KVM guests it is required for graceful shutdown to work.
D
Daniel P. Berrange 已提交
1384
      </dd>
1385 1386
      <dt><code>apic</code></dt>
      <dd>APIC allows the use of programmable IRQ
1387 1388 1389
      management. <span class="since">Since 0.10.2 (QEMU only)</span> there is
      an optional attribute <code>eoi</code> with values <code>on</code>
      and <code>off</code> which toggles the availability of EOI (End of
1390 1391
      Interrupt) for the guest.
      </dd>
J
Jim Fehlig 已提交
1392 1393 1394 1395
      <dt><code>hap</code></dt>
      <dd>Enable use of Hardware Assisted Paging if available in
        the hardware.
      </dd>
1396 1397 1398 1399
      <dt><code>viridian</code></dt>
      <dd>Enable Viridian hypervisor extensions for paravirtualizing
        guest operating systems
      </dd>
1400 1401 1402 1403 1404 1405
      <dt><code>privnet</code></dt>
      <dd>Always create a private network namespace. This is
        automatically set if any interface devices are defined.
        This feature is only relevant for container based
        virtualization drivers, such as LXC.
      </dd>
1406 1407 1408 1409 1410 1411 1412 1413
      <dt><code>hyperv</code></dt>
      <dd>Enable various features improving behavior of guests
        running Microsoft Windows.
      <table class="top_table">
        <tr>
          <th>Feature</th>
          <th>Description</th>
          <th>Value</th>
1414
          <th>Since</th>
1415 1416 1417
        </tr>
        <tr>
          <td>relaxed</td>
1418
          <td>Relax constraints on timers</td>
1419
          <td> on, off</td>
1420 1421 1422 1423 1424 1425 1426 1427 1428 1429 1430 1431 1432
          <td><span class="since">1.0.0 (QEMU only)</span></td>
        </tr>
        <tr>
          <td>vapic</td>
          <td>Enable virtual APIC</td>
          <td>on, off</td>
          <td><span class="since">1.1.0 (QEMU only)</span></td>
        </tr>
        <tr>
          <td>spinlocks</td>
          <td>Enable spinlock support</td>
          <td>on, off; retries - at least 4095</td>
          <td><span class="since">1.1.0 (QEMU only)</span></td>
1433 1434 1435
        </tr>
      </table>
      </dd>
1436 1437 1438 1439 1440 1441
      <dt><code>pvspinlock</code></dt>
      <dd>Notify the guest that the host supports paravirtual spinlocks
          for example by exposing the pvticketlocks mechanism. This feature
          can be explicitly disabled by using <code>state='off'</code>
          attribute.
      </dd>
1442 1443 1444 1445 1446 1447 1448 1449 1450 1451 1452 1453 1454 1455 1456 1457 1458
      <dt><code>kvm</code></dt>
      <dd>Various features to change the behavior of the KVM hypervisor.
      <table class="top_table">
        <tr>
          <th>Feature</th>
          <th>Description</th>
          <th>Value</th>
          <th>Since</th>
        </tr>
        <tr>
          <td>hidden</td>
          <td>Hide the KVM hypervisor from standard MSR based discovery</td>
          <td>on, off</td>
          <td><span class="since">2.1.0 (QEMU only)</span></td>
        </tr>
      </table>
      </dd>
D
Daniel P. Berrange 已提交
1459 1460 1461 1462 1463 1464 1465 1466 1467 1468 1469
    </dl>

    <h3><a name="elementsTime">Time keeping</a></h3>

    <p>
      The guest clock is typically initialized from the host clock.
      Most operating systems expect the hardware clock to be kept
      in UTC, and this is the default. Windows, however, expects
      it to be in so called 'localtime'.
    </p>

1470 1471
<pre>
  ...
1472 1473 1474
  &lt;clock offset='localtime'&gt;
    &lt;timer name='rtc' tickpolicy='catchup' track='guest'&gt;
      &lt;catchup threshold='123' slew='120' limit='10000'/&gt;
1475
    &lt;/timer&gt;
1476
    &lt;timer name='pit' tickpolicy='delay'/&gt;
1477
  &lt;/clock&gt;
1478
  ...</pre>
D
Daniel P. Berrange 已提交
1479 1480 1481

    <dl>
      <dt><code>clock</code></dt>
1482
      <dd>
E
Eric Blake 已提交
1483 1484 1485 1486 1487 1488 1489 1490
        <p>The <code>offset</code> attribute takes four possible
          values, allowing fine grained control over how the guest
          clock is synchronized to the host. NB, not all hypervisors
          support all modes.</p>
        <dl>
          <dt><code>utc</code></dt>
          <dd>
            The guest clock will always be synchronized to UTC when
1491 1492 1493 1494 1495 1496 1497 1498 1499 1500 1501
            booted.
            <span class="since">Since 0.9.11</span> 'utc' mode can be converted
            to 'variable' mode, which can be controlled by using the
            <code>adjustment</code> attribute. If the value is 'reset', the
            conversion is never done (not all hypervisors can
            synchronize to UTC on each boot; use of 'reset' will cause
            an error on those hypervisors). A numeric value
            forces the conversion to 'variable' mode using the value as the
            initial adjustment. The default <code>adjustment</code> is
            hypervisor specific.
          </dd>
E
Eric Blake 已提交
1502 1503 1504 1505
          <dt><code>localtime</code></dt>
          <dd>
            The guest clock will be synchronized to the host's configured
            timezone when booted, if any.
1506 1507
            <span class="since">Since 0.9.11,</span> the <code>adjustment</code>
            attribute behaves the same as in 'utc' mode.
E
Eric Blake 已提交
1508 1509 1510 1511 1512 1513 1514 1515 1516 1517
          </dd>
          <dt><code>timezone</code></dt>
          <dd>
            The guest clock will be synchronized to the requested timezone
            using the <code>timezone</code> attribute.
            <span class="since">Since 0.7.7</span>
          </dd>
          <dt><code>variable</code></dt>
          <dd>
            The guest clock will have an arbitrary offset applied
1518 1519
            relative to UTC or localtime, depending on the <code>basis</code>
            attribute. The delta relative to UTC (or localtime) is specified
E
Eric Blake 已提交
1520
            in seconds, using the <code>adjustment</code> attribute.
P
Philipp Hahn 已提交
1521
            The guest is free to adjust the RTC over time and expect
1522 1523 1524
            that it will be honored at next reboot. This is in
            contrast to 'utc' and 'localtime' mode (with the optional
            attribute adjustment='reset'), where the RTC adjustments are
E
Eric Blake 已提交
1525
            lost at each reboot. <span class="since">Since 0.7.7</span>
1526 1527
            <span class="since">Since 0.9.11</span> the <code>basis</code>
            attribute can be either 'utc' (default) or 'localtime'.
E
Eric Blake 已提交
1528 1529 1530 1531
          </dd>
        </dl>
        <p>
          A <code>clock</code> may have zero or more
1532
          <code>timer</code> sub-elements. <span class="since">Since
E
Eric Blake 已提交
1533 1534
          0.8.0</span>
        </p>
D
Daniel P. Berrange 已提交
1535
      </dd>
1536 1537
      <dt><code>timer</code></dt>
      <dd>
E
Eric Blake 已提交
1538 1539 1540 1541 1542 1543 1544 1545 1546 1547
        <p>
          Each timer element requires a <code>name</code> attribute,
          and has other optional attributes that depend on
          the <code>name</code> specified.  Various hypervisors
          support different combinations of attributes.
        </p>
        <dl>
          <dt><code>name</code></dt>
          <dd>
            The <code>name</code> attribute selects which timer is
1548 1549 1550
            being modified, and can be one of
            "platform" (currently unsupported),
            "hpet" (libxl, xen, qemu), "kvmclock" (qemu),
1551 1552 1553 1554 1555 1556 1557
            "pit" (qemu), "rtc" (qemu), "tsc" (libxl) or "hypervclock"
            (qemu - <span class="since">since 1.2.2</span>).

            The <code>hypervclock</code> timer adds support for the
            reference time counter and the reference page for iTSC
            feature for guests running the Microsoft Windows
            operating system.
E
Eric Blake 已提交
1558 1559 1560 1561 1562 1563 1564 1565 1566 1567
          </dd>
          <dt><code>track</code></dt>
          <dd>
            The <code>track</code> attribute specifies what the timer
            tracks, and can be "boot", "guest", or "wall".
            Only valid for <code>name="rtc"</code>
            or <code>name="platform"</code>.
          </dd>
          <dt><code>tickpolicy</code></dt>
          <dd>
1568 1569
            <p>
            The <code>tickpolicy</code> attribute determines what
1570
            happens when QEMU misses a deadline for injecting a
1571 1572 1573 1574 1575 1576 1577 1578 1579 1580 1581 1582 1583 1584 1585 1586 1587 1588 1589 1590 1591 1592 1593
            tick to the guest:
            </p>
            <dl>
              <dt><code>delay</code></dt>
              <dd>Continue to deliver ticks at the normal rate.
                The guest time will be delayed due to the late
                tick</dd>
              <dt><code>catchup</code></dt>
              <dd>Deliver ticks at a higher rate to catch up
                with the missed tick. The guest time should
                not be delayed once catchup is complete.</dd>
              <dt><code>merge</code></dt>
              <dd>Merge the missed tick(s) into one tick and
                inject. The guest time may be delayed, depending
                on how the OS reacts to the merging of ticks</dd>
              <dt><code>discard</code></dt>
              <dd>Throw away the missed tick(s) and continue
                with future injection normally. The guest time
                may be delayed, unless the OS has explicit
                handling of lost ticks</dd>
            </dl>
            <p>If the policy is "catchup", there can be further details in
            the <code>catchup</code> sub-element.</p>
E
Eric Blake 已提交
1594 1595 1596 1597 1598 1599 1600 1601 1602
            <dl>
              <dt><code>catchup</code></dt>
              <dd>
                The <code>catchup</code> element has three optional
                attributes, each a positive integer.  The attributes
                are <code>threshold</code>, <code>slew</code>,
                and <code>limit</code>.
              </dd>
            </dl>
1603 1604 1605
            <p>
              Note that hypervisors are not required to support all policies across all time sources
            </p>
E
Eric Blake 已提交
1606 1607 1608 1609 1610 1611 1612 1613 1614 1615 1616 1617 1618 1619 1620 1621 1622 1623 1624 1625
          </dd>
          <dt><code>frequency</code></dt>
          <dd>
            The <code>frequency</code> attribute is an unsigned
            integer specifying the frequency at
            which <code>name="tsc"</code> runs.
          </dd>
          <dt><code>mode</code></dt>
          <dd>
            The <code>mode</code> attribute controls how
            the <code>name="tsc"</code> timer is managed, and can be
            "auto", "native", "emulate", "paravirt", or "smpsafe".
            Other timers are always emulated.
          </dd>
          <dt><code>present</code></dt>
          <dd>
            The <code>present</code> attribute can be "yes" or "no" to
            specify whether a particular timer is available to the guest.
          </dd>
        </dl>
1626
      </dd>
D
Daniel P. Berrange 已提交
1627 1628 1629 1630 1631
    </dl>

    <h3><a name="elementsDevices">Devices</a></h3>

    <p>
A
Atsushi SAKAI 已提交
1632
      The final set of XML elements are all used to describe devices
D
Daniel P. Berrange 已提交
1633 1634 1635 1636 1637
      provided to the guest domain. All devices occur as children
      of the main <code>devices</code> element.
      <span class="since">Since 0.1.3</span>
    </p>

1638 1639 1640 1641 1642 1643
<pre>
  ...
  &lt;devices&gt;
    &lt;emulator&gt;/usr/lib/xen/bin/qemu-dm&lt;/emulator&gt;
  &lt;/devices&gt;
  ...</pre>
D
Daniel P. Berrange 已提交
1644 1645 1646 1647

    <dl>
      <dt><code>emulator</code></dt>
      <dd>
M
Matthew Booth 已提交
1648 1649 1650 1651 1652
        The contents of the <code>emulator</code> element specify
        the fully qualified path to the device model emulator binary.
        The <a href="formatcaps.html">capabilities XML</a> specifies
        the recommended default emulator to use for each particular
        domain type / architecture combination.
D
Daniel P. Berrange 已提交
1653 1654 1655 1656 1657 1658 1659 1660 1661 1662 1663
      </dd>
    </dl>

    <h4><a name="elementsDisks">Hard drives, floppy disks, CDROMs</a></h4>

    <p>
      Any device that looks like a disk, be it a floppy, harddisk,
      cdrom, or paravirtualized driver is specified via the <code>disk</code>
      element.
    </p>

1664 1665 1666
<pre>
  ...
  &lt;devices&gt;
1667
    &lt;disk type='file' snapshot='external'&gt;
1668
      &lt;driver name="tap" type="aio" cache="default"/&gt;
E
Eric Blake 已提交
1669
      &lt;source file='/var/lib/xen/images/fv0' startupPolicy='optional'&gt;
1670 1671
        &lt;seclabel relabel='no'/&gt;
      &lt;/source&gt;
1672
      &lt;target dev='hda' bus='ide'/&gt;
L
Lei Li 已提交
1673 1674 1675 1676 1677
      &lt;iotune&gt;
        &lt;total_bytes_sec&gt;10000000&lt;/total_bytes_sec&gt;
        &lt;read_iops_sec&gt;400000&lt;/read_iops_sec&gt;
        &lt;write_iops_sec&gt;100000&lt;/write_iops_sec&gt;
      &lt;/iotune&gt;
1678
      &lt;boot order='2'/&gt;
1679 1680 1681 1682
      &lt;encryption type='...'&gt;
        ...
      &lt;/encryption&gt;
      &lt;shareable/&gt;
1683 1684 1685
      &lt;serial&gt;
        ...
      &lt;/serial&gt;
1686
    &lt;/disk&gt;
M
MORITA Kazutaka 已提交
1687 1688
      ...
    &lt;disk type='network'&gt;
1689
      &lt;driver name="qemu" type="raw" io="threads" ioeventfd="on" event_idx="off"/&gt;
M
MORITA Kazutaka 已提交
1690 1691 1692 1693
      &lt;source protocol="sheepdog" name="image_name"&gt;
        &lt;host name="hostname" port="7000"/&gt;
      &lt;/source&gt;
      &lt;target dev="hdb" bus="ide"/&gt;
1694
      &lt;boot order='1'/&gt;
1695
      &lt;transient/&gt;
E
Eric Blake 已提交
1696
      &lt;address type='drive' controller='0' bus='1' unit='0'/&gt;
M
MORITA Kazutaka 已提交
1697
    &lt;/disk&gt;
1698 1699 1700 1701
    &lt;disk type='network'&gt;
      &lt;driver name="qemu" type="raw"/&gt;
      &lt;source protocol="rbd" name="image_name2"&gt;
        &lt;host name="hostname" port="7000"/&gt;
1702
        &lt;snapshot name="snapname"/&gt;
1703
        &lt;config file="/path/to/file"/&gt;
1704
      &lt;/source&gt;
1705
      &lt;target dev="hdc" bus="ide"/&gt;
1706 1707 1708 1709
      &lt;auth username='myuser'&gt;
        &lt;secret type='ceph' usage='mypassid'/&gt;
      &lt;/auth&gt;
    &lt;/disk&gt;
1710 1711
    &lt;disk type='block' device='cdrom'&gt;
      &lt;driver name='qemu' type='raw'/&gt;
1712
      &lt;target dev='hdd' bus='ide' tray='open'/&gt;
1713 1714
      &lt;readonly/&gt;
    &lt;/disk&gt;
1715 1716 1717 1718 1719
    &lt;disk type='network' device='cdrom'&gt;
      &lt;driver name='qemu' type='raw'/&gt;
      &lt;source protocol="http" name="url_path"&gt;
        &lt;host name="hostname" port="80"/&gt;
      &lt;/source&gt;
1720
      &lt;target dev='hde' bus='ide' tray='open'/&gt;
1721 1722
      &lt;readonly/&gt;
    &lt;/disk&gt;
1723 1724 1725 1726 1727
    &lt;disk type='network' device='cdrom'&gt;
      &lt;driver name='qemu' type='raw'/&gt;
      &lt;source protocol="https" name="url_path"&gt;
        &lt;host name="hostname" port="443"/&gt;
      &lt;/source&gt;
1728
      &lt;target dev='hdf' bus='ide' tray='open'/&gt;
1729 1730
      &lt;readonly/&gt;
    &lt;/disk&gt;
1731 1732 1733 1734 1735
    &lt;disk type='network' device='cdrom'&gt;
      &lt;driver name='qemu' type='raw'/&gt;
      &lt;source protocol="ftp" name="url_path"&gt;
        &lt;host name="hostname" port="21"/&gt;
      &lt;/source&gt;
1736
      &lt;target dev='hdg' bus='ide' tray='open'/&gt;
1737 1738
      &lt;readonly/&gt;
    &lt;/disk&gt;
1739 1740 1741 1742 1743
    &lt;disk type='network' device='cdrom'&gt;
      &lt;driver name='qemu' type='raw'/&gt;
      &lt;source protocol="ftps" name="url_path"&gt;
        &lt;host name="hostname" port="990"/&gt;
      &lt;/source&gt;
1744
      &lt;target dev='hdh' bus='ide' tray='open'/&gt;
1745 1746
      &lt;readonly/&gt;
    &lt;/disk&gt;
1747 1748 1749 1750 1751
    &lt;disk type='network' device='cdrom'&gt;
      &lt;driver name='qemu' type='raw'/&gt;
      &lt;source protocol="tftp" name="url_path"&gt;
        &lt;host name="hostname" port="69"/&gt;
      &lt;/source&gt;
1752
      &lt;target dev='hdi' bus='ide' tray='open'/&gt;
1753 1754
      &lt;readonly/&gt;
    &lt;/disk&gt;
1755 1756
    &lt;disk type='block' device='lun'&gt;
      &lt;driver name='qemu' type='raw'/&gt;
O
Osier Yang 已提交
1757 1758 1759
      &lt;source dev='/dev/sda'/&gt;
      &lt;target dev='sda' bus='scsi'/&gt;
      &lt;address type='drive' controller='0' bus='0' target='3' unit='0'/&gt;
1760
    &lt;/disk&gt;
J
J.B. Joret 已提交
1761 1762 1763 1764
    &lt;disk type='block' device='disk'&gt;
      &lt;driver name='qemu' type='raw'/&gt;
      &lt;source dev='/dev/sda'/&gt;
      &lt;geometry cyls='16383' heads='16' secs='63' trans='lba'/&gt;
V
Viktor Mihajlovski 已提交
1765
      &lt;blockio logical_block_size='512' physical_block_size='4096'/&gt;
1766
      &lt;target dev='hdj' bus='ide'/&gt;
J
J.B. Joret 已提交
1767
    &lt;/disk&gt;
1768 1769 1770
    &lt;disk type='volume' device='disk'&gt;
      &lt;driver name='qemu' type='raw'/&gt;
      &lt;source pool='blk-pool0' volume='blk-pool0-vol0'/&gt;
1771
      &lt;target dev='hdk' bus='ide'/&gt;
1772
    &lt;/disk&gt;
1773 1774 1775 1776 1777 1778
    &lt;disk type='network' device='disk'&gt;
      &lt;driver name='qemu' type='raw'/&gt;
      &lt;source protocol='iscsi' name='iqn.2013-07.com.example:iscsi-nopool/2'&gt;
        &lt;host name='example.com' port='3260'/&gt;
      &lt;/source&gt;
      &lt;auth username='myuser'&gt;
1779
        &lt;secret type='iscsi' usage='libvirtiscsi'/&gt;
1780 1781 1782 1783 1784 1785 1786 1787 1788
      &lt;/auth&gt;
      &lt;target dev='vda' bus='virtio'/&gt;
    &lt;/disk&gt;
    &lt;disk type='network' device='lun'&gt;
      &lt;driver name='qemu' type='raw'/&gt;
      &lt;source protocol='iscsi' name='iqn.2013-07.com.example:iscsi-nopool/1'&gt;
        &lt;host name='example.com' port='3260'/&gt;
      &lt;/source&gt;
      &lt;auth username='myuser'&gt;
1789
        &lt;secret type='iscsi' usage='libvirtiscsi'/&gt;
1790
      &lt;/auth&gt;
1791
      &lt;target dev='sdb' bus='scsi'/&gt;
1792 1793 1794 1795 1796
    &lt;/disk&gt;
    &lt;disk type='volume' device='disk'&gt;
      &lt;driver name='qemu' type='raw'/&gt;
      &lt;source pool='iscsi-pool' volume='unit:0:0:1' mode='host'/&gt;
      &lt;auth username='myuser'&gt;
1797
        &lt;secret type='iscsi' usage='libvirtiscsi'/&gt;
1798
      &lt;/auth&gt;
1799
      &lt;target dev='vdb' bus='virtio'/&gt;
1800 1801 1802 1803 1804
    &lt;/disk&gt;
    &lt;disk type='volume' device='disk'&gt;
      &lt;driver name='qemu' type='raw'/&gt;
      &lt;source pool='iscsi-pool' volume='unit:0:0:2' mode='direct'/&gt;
      &lt;auth username='myuser'&gt;
1805
        &lt;secret type='iscsi' usage='libvirtiscsi'/&gt;
1806
      &lt;/auth&gt;
1807
      &lt;target dev='vdc' bus='virtio'/&gt;
1808
    &lt;/disk&gt;
1809 1810 1811 1812 1813 1814 1815 1816 1817 1818 1819 1820
    &lt;disk type='file' device='disk'&gt;
      &lt;driver name='qemu' type='qcow2'/&gt;
      &lt;source file='/var/lib/libvirt/images/domain.qcow'/&gt;
      &lt;backingStore type='file'&gt;
        &lt;format type='qcow2'/&gt;
        &lt;source file='/var/lib/libvirt/images/snapshot.qcow'/&gt;
        &lt;backingStore type='block'&gt;
          &lt;format type='raw'/&gt;
          &lt;source dev='/dev/mapper/base'/&gt;
          &lt;backingStore/&gt;
        &lt;/backingStore&gt;
      &lt;/backingStore&gt;
1821
      &lt;target dev='vdd' bus='virtio'/&gt;
1822
    &lt;/disk&gt;
1823 1824
  &lt;/devices&gt;
  ...</pre>
D
Daniel P. Berrange 已提交
1825 1826 1827 1828

    <dl>
      <dt><code>disk</code></dt>
      <dd>The <code>disk</code> element is the main container for describing
1829 1830 1831 1832 1833 1834 1835 1836 1837 1838 1839 1840 1841 1842 1843 1844 1845 1846 1847
      disks (<span class="since">since 0.0.3</span>).
        <dl>
          <dt><code>type</code> attribute
          <span class="since">since 0.0.3</span></dt>
            <dd>
            Valid values are "file", "block",
            "dir" (<span class="since">since 0.7.5</span>),
            "network" (<span class="since">since 0.8.7</span>), or
            "volume" (<span class="since">since 1.0.5</span>)
            and refer to the underlying source for the disk.
            </dd>
          <dt><code>device</code> attribute
          <span class="since">since 0.1.4</span></dt>
            <dd>
            Indicates how the disk is to be exposed to the guest OS. Possible
            values for this attribute are "floppy", "disk", "cdrom", and "lun",
            defaulting to "disk".
            <p>
            Using "lun" (<span class="since">since 0.9.10</span>) is only
1848 1849
            valid when type is "block" or "network" using the iSCSI protocol,
            and behaves identically to "disk",
1850 1851 1852 1853 1854 1855 1856 1857 1858 1859 1860
            except that generic SCSI commands from the guest are accepted
            and passed through to the physical device. Also note that
            device='lun' will only be recognized for actual raw devices,
            but never for individual partitions or LVM partitions (in those
            cases, the kernel will reject the generic SCSI commands, making
            it identical to device='disk').
            </p>
            </dd>
          <dt><code>rawio</code> attribute
          <span class="since">since 0.9.10</span></dt>
            <dd>
1861
            Indicates whether the disk needs rawio capability. Valid
1862 1863 1864 1865 1866 1867 1868 1869 1870 1871 1872 1873 1874 1875 1876 1877 1878 1879 1880 1881 1882 1883 1884 1885 1886 1887 1888 1889 1890 1891 1892 1893 1894 1895 1896 1897 1898 1899
            settings are "yes" or "no" (default is "no"). If any one disk
            in a domain has rawio='yes', rawio capability will be enabled
            for all disks in the domain (because, in the case of QEMU, this
            capability can only be set on a per-process basis). This attribute
            is only valid when device is "lun". NB, <code>rawio</code> intends
            to confine the capability per-device, however, current QEMU
            implementation gives the domain process broader capability
            than that (per-process basis, affects all the domain disks).
            To confine the capability as much as possible for QEMU driver
            as this stage, <code>sgio</code> is recommended, it's more
            secure than <code>rawio</code>.
            </dd>
          <dt><code>sgio</code> attribute
          <span class="since">since 1.0.2</span></dt>
            <dd>
            Indicates whether the kernel will filter unprivileged
            SG_IO commands for the disk, valid settings are "filtered" or
            "unfiltered". Defaults to "filtered". Similar to <code>rawio</code>,
            <code>sgio</code> is only valid for device 'lun'.
            </dd>
          <dt><code>snapshot</code> attribute
          <span class="since">since 0.9.5</span></dt>
            <dd>
            Indicates the default behavior of the disk during disk snapshots:
            "internal" requires a file format such as qcow2 that can store
            both the snapshot and the data changes since the snapshot;
            "external" will separate the snapshot from the live data; and
            "no" means the disk will not participate in snapshots. Read-only
            disks default to "no", while the default for other disks depends
            on the hypervisor's capabilities.  Some hypervisors allow a
            per-snapshot choice as well, during
            <a href="formatsnapshot.html">domain snapshot creation</a>.
            Not all snapshot modes are supported; for example,
            <code>snapshot='yes'</code> with a transient disk generally
            does not make sense.
            </dd>
        </dl>
      </dd>
D
Daniel P. Berrange 已提交
1900
      <dt><code>source</code></dt>
1901 1902 1903 1904 1905 1906 1907 1908 1909 1910 1911 1912 1913 1914 1915 1916 1917 1918 1919 1920 1921 1922 1923 1924 1925 1926 1927 1928 1929 1930 1931 1932 1933 1934 1935 1936 1937 1938 1939 1940 1941 1942 1943 1944 1945 1946 1947 1948 1949 1950 1951 1952 1953 1954 1955 1956 1957 1958 1959 1960 1961 1962 1963 1964 1965 1966 1967 1968 1969
      <dd>Representation of the disk <code>source</code> depends on the
      disk <code>type</code> attribute value as follows:
          <dl>
            <dt><code>type='file'</code>
            <span class="since">since 0.0.3</span></dt>
              <dd>
              The <code>file</code> attribute specifies the fully-qualified
              path to the file holding the disk.
              </dd>
            <dt><code>type='block'</code>
            <span class="since">since 0.0.3</span></dt>
              <dd>
              The <code>dev</code> attribute specifies the path to the
              host device to serve as the disk.
              </dd>
            <dt><code>type='dir'</code>
            <span class="since">since 0.7.5</span></dt>
              <dd>
              The <code>dir</code> attribute specifies the fully-qualified path
              to the directory to use as the disk.
              </dd>
            <dt><code>type='network'</code>
            <span class="since">since 0.8.7</span></dt>
              <dd>
              The <code>protocol</code> attribute specifies the protocol to
              access to the requested image. Possible values are "nbd",
              "iscsi", "rbd", "sheepdog" or "gluster".  If the
              <code>protocol</code> attribute is "rbd", "sheepdog" or
              "gluster", an additional attribute <code>name</code> is
              mandatory to specify which volume/image will be used. For "nbd",
              the <code>name</code> attribute is optional. For "iscsi"
              (<span class="since">since 1.0.4</span>), the <code>name</code>
              attribute may include a logical unit number, separated from the
              target's name by a slash (e.g.,
              <code>iqn.2013-07.com.example:iscsi-pool/1</code>). If not
              specified, the default LUN is zero.
              </dd>
            <dt><code>type='volume'</code>
            <span class="since">since 1.0.5</span></dt>
              <dd>
              The underlying disk source is represented by attributes
              <code>pool</code> and <code>volume</code>. Attribute
              <code>pool</code> specifies the name of the
              <a href="formatstorage.html">storage pool</a> (managed
              by libvirt) where the disk source resides. Attribute
              <code>volume</code> specifies the name of storage volume (managed
              by libvirt) used as the disk source. The value for the
              <code>volume</code> attribute will be the output from the "Name"
              column of a <code>virsh vol-list [pool-name]</code> command.
              <p>
              Use the attribute <code>mode</code>
              (<span class="since">since 1.1.1</span>) to indicate how to
              represent the LUN as the disk source. Valid values are
              "direct" and "host". If <code>mode</code> is not specified,
              the default is to use "host".

              Using "direct" as the <code>mode</code> value indicates to use
              the <a href="formatstorage.html">storage pool's</a>
              <code>source</code> element <code>host</code> attribute as
              the disk source to generate the libiscsi URI (e.g.
              'file=iscsi://example.com:3260/iqn.2013-07.com.example:iscsi-pool/1').

              Using "host" as the <code>mode</code> value indicates to use the
              LUN's path as it shows up on host (e.g.
              'file=/dev/disk/by-path/ip-example.com:3260-iscsi-iqn.2013-07.com.example:iscsi-pool-lun-1').
              </p>
              </dd>
          </dl>
        With "file", "block", and "volume", one or more optional
1970
        sub-elements <code>seclabel</code>, <a href="#seclabel">described
1971 1972
        below</a> (and <span class="since">since 0.9.9</span>), can be
        used to override the domain security labeling policy for just
1973 1974
        that source file. (NB, for "volume" type disk, <code>seclabel</code>
        is only valid when the specified storage volume is of 'file' or
1975 1976
        'block' type).
        <p>
1977
        The <code>source</code> element may contain the following sub elements:
1978
        </p>
1979 1980 1981 1982 1983

        <dl>
          <dt><code>host</code></dt>
          <dd>
            <p>
1984 1985 1986 1987
            When the disk <code>type</code> is "network", the <code>source</code>
            may have zero or more <code>host</code> sub-elements used to
            specify the hosts to connect.

1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034 2035 2036 2037 2038 2039
            The <code>host</code> element supports 4 attributes, viz.  "name",
            "port", "transport" and "socket", which specify the hostname,
            the port number, transport type and path to socket, respectively.
            The meaning of this element and the number of the elements depend
            on the protocol attribute.
            </p>
            <table class="top_table">
              <tr>
                <th> Protocol </th>
                <th> Meaning </th>
                <th> Number of hosts </th>
                <th> Default port </th>
              </tr>
              <tr>
                <td> nbd </td>
                <td> a server running nbd-server </td>
                <td> only one </td>
                <td> 10809 </td>
              </tr>
              <tr>
                <td> iscsi </td>
                <td> an iSCSI server </td>
                <td> only one </td>
                <td> 3260 </td>
              </tr>
              <tr>
                <td> rbd </td>
                <td> monitor servers of RBD </td>
                <td> one or more </td>
                <td> 6789 </td>
              </tr>
              <tr>
                <td> sheepdog </td>
                <td> one of the sheepdog servers (default is localhost:7000) </td>
                <td> zero or one </td>
                <td> 7000 </td>
              </tr>
              <tr>
                <td> gluster </td>
                <td> a server running glusterd daemon </td>
                <td> only one </td>
                <td> 24007 </td>
              </tr>
            </table>
            <p>
            gluster supports "tcp", "rdma", "unix" as valid values for the
            transport attribute.  nbd supports "tcp" and "unix".  Others only
            support "tcp".  If nothing is specified, "tcp" is assumed. If the
            transport is "unix", the socket attribute specifies the path to an
            AF_UNIX socket.
            </p>
          </dd>
2040 2041 2042 2043 2044 2045 2046
          <dt><code>snapshot</code></dt>
          <dd>
            The <code>name</code> attribute of <code>snapshot</code> element can
            optionally specify an internal snapshot name to be used as the
            source for storage protocols.
            Supported for 'rbd' <span class="since">since 1.2.11 (QEMU only).</span>
          </dd>
2047 2048 2049 2050 2051 2052 2053 2054
          <dt><code>config</code></dt>
          <dd>
            The <code>file</code> attribute for the <code>config</code> element
            provides a fully qualified path to a configuration file to be
            provided as a parameter to the client of a networked storage
            protocol. Supported for 'rbd' <span class="since">since 1.2.11
            (QEMU only).</span>
          </dd>
2055 2056
        </dl>

2057
        <p>
2058
        For a "file" or "volume" disk type which represents a cdrom or floppy
2059 2060
        (the <code>device</code> attribute), it is possible to define
        policy what to do with the disk if the source file is not accessible.
2061 2062
        (NB, <code>startupPolicy</code> is not valid for "volume" disk unless
         the specified storage volume is of "file" type). This is done by the
2063 2064
        <code>startupPolicy</code> attribute
        (<span class="since">since 0.9.7</span>),
2065
        accepting these values:
2066
        </p>
2067 2068 2069 2070 2071 2072 2073 2074 2075 2076 2077 2078 2079 2080 2081
        <table class="top_table">
          <tr>
            <td> mandatory </td>
            <td> fail if missing for any reason (the default) </td>
          </tr>
          <tr>
            <td> requisite </td>
            <td> fail if missing on boot up,
                 drop if missing on migrate/restore/revert </td>
          </tr>
          <tr>
            <td> optional </td>
            <td> drop if missing at any start attempt </td>
          </tr>
        </table>
2082 2083 2084 2085 2086 2087 2088
        <p>
        <span class="since">Since 1.1.2</span> the <code>startupPolicy</code>
        is extended to support hard disks besides cdrom and floppy. On guest
        cold bootup, if a certain disk is not accessible or its disk chain is
        broken, with startupPolicy 'optional' the guest will drop this disk.
        This feature doesn't support migration currently.
        </p>
2089
        </dd>
2090 2091 2092 2093 2094 2095 2096 2097 2098 2099 2100 2101 2102 2103 2104 2105 2106 2107 2108 2109 2110 2111 2112 2113 2114 2115 2116 2117 2118 2119 2120 2121 2122 2123 2124 2125 2126 2127 2128 2129 2130 2131 2132 2133 2134 2135 2136
      <dt><code>backingStore</code></dt>
      <dd>
        This element describes the backing store used by the disk specified by
        sibling <code>source</code> element. It is currently ignored on input
        and only used for output to describe the detected backing chains.
        <span class="since">Since 1.2.4</span>. An empty
        <code>backingStore</code> element means the sibling source is
        self-contained and is not based on any backing store. The following
        attributes and sub-elements are supported in
        <code>backingStore</code>:
        <dl>
          <dt><code>type</code> attribute</dt>
          <dd>
            The <code>type</code> attribute represents the type of disk used
            by the backing store, see disk type attribute above for more
            details and possible values.
          </dd>
          <dt><code>index</code> attribute</dt>
          <dd>
            This attribute is only valid in output (and ignored on input) and
            it can be used to refer to a specific part of the disk chain when
            doing block operations (such as via the
            <code>virDomainBlockRebase</code> API). For example,
            <code>vda[2]</code> refers to the backing store with
            <code>index='2'</code> of the disk with <code>vda</code> target.
          </dd>
          <dt><code>format</code> sub-element</dt>
          <dd>
            The <code>format</code> element contains <code>type</code>
            attribute which specifies the internal format of the backing
            store, such as <code>raw</code> or <code>qcow2</code>.
          </dd>
          <dt><code>source</code> sub-element</dt>
          <dd>
            This element has the same structure as the <code>source</code>
            element in <code>disk</code>. It specifies which file, device,
            or network location contains the data of the described backing
            store.
          </dd>
          <dt><code>backingStore</code> sub-element</dt>
          <dd>
            If the backing store is not self-contained, the next element
            in the chain is described by nested <code>backingStore</code>
            element.
          </dd>
        </dl>
      </dd>
2137 2138
      <dt><code>mirror</code></dt>
      <dd>
E
Eric Blake 已提交
2139 2140 2141 2142
        This element is present if the hypervisor has started a
        long-running block job operation, where the mirror location in
        the <code>source</code> sub-element will eventually have the
        same contents as the source, and with the file format in the
E
Eric Blake 已提交
2143 2144 2145 2146
        sub-element <code>format</code> (which might differ from the
        format of the source).  The details of the <code>source</code>
        sub-element are determined by the <code>type</code> attribute
        of the mirror, similar to what is done for the
E
Eric Blake 已提交
2147 2148 2149 2150 2151
        overall <code>disk</code> device element. The <code>job</code>
        attribute mentions which API started the operation ("copy" for
        the <code>virDomainBlockRebase</code> API, or "active-commit"
        for the <code>virDomainBlockCommit</code>
        API), <span class="since">since 1.2.7</span>.  The
2152 2153 2154 2155 2156 2157
        attribute <code>ready</code>, if present, tracks progress of
        the job: <code>yes</code> if the disk is known to be ready to
        pivot, or, <span class="since">since
        1.2.7</span>, <code>abort</code> or <code>pivot</code> if the
        job is in the process of completing.  If <code>ready</code> is
        not present, the disk is probably still
2158
        copying.  For now, this element only valid in output; it is
2159 2160 2161 2162 2163 2164 2165
        ignored on input.  The <code>source</code> sub-element exists
        for all two-phase jobs <span class="since">since 1.2.6</span>.
        Older libvirt supported only block copy to a
        file, <span class="since">since 0.9.12</span>; for
        compatibility with older clients, such jobs include redundant
        information in the attributes <code>file</code>
        and <code>format</code> in the <code>mirror</code> element.
2166
      </dd>
D
Daniel P. Berrange 已提交
2167
      <dt><code>target</code></dt>
E
Eric Blake 已提交
2168 2169 2170 2171 2172 2173 2174 2175
      <dd>The <code>target</code> element controls the bus / device
        under which the disk is exposed to the guest
        OS. The <code>dev</code> attribute indicates the "logical"
        device name. The actual device name specified is not
        guaranteed to map to the device name in the guest OS. Treat it
        as a device ordering hint.  The optional <code>bus</code>
        attribute specifies the type of disk device to emulate;
        possible values are driver specific, with typical values being
2176 2177
        "ide", "scsi", "virtio", "xen", "usb", "sata", or
        "sd" <span class="since">"sd" since 1.1.2</span>. If omitted, the bus
M
Martin Kletzander 已提交
2178 2179
        type is inferred from the style of the device name (e.g. a device named
        'sda' will typically be exported using a SCSI bus). The optional
2180 2181 2182 2183
        attribute <code>tray</code> indicates the tray status of the
        removable disks (i.e. CDROM or Floppy disk), the value can be either
        "open" or "closed", defaults to "closed". NB, the value of
        <code>tray</code> could be updated while the domain is running.
2184 2185 2186 2187
        The optional attribute <code>removable</code> sets the
        removable flag for USB disks, and its value can be either "on"
        or "off", defaulting to "off". <span class="since">Since
        0.0.3; <code>bus</code> attribute since 0.4.3;
2188
        <code>tray</code> attribute since 0.9.11; "usb" attribute value since
2189 2190
        after 0.4.4; "sata" attribute value since 0.9.7; "removable" attribute
        value since 1.1.3</span>
2191
      </dd>
L
Lei Li 已提交
2192 2193 2194 2195 2196 2197 2198 2199 2200 2201 2202 2203 2204 2205 2206 2207 2208 2209 2210 2211 2212 2213 2214 2215 2216 2217 2218 2219 2220 2221 2222 2223 2224
      <dt><code>iotune</code></dt>
      <dd>The optional <code>iotune</code> element provides the
        ability to provide additional per-device I/O tuning, with
        values that can vary for each device (contrast this to
        the <a href="#elementsBlockTuning"><code>&lt;blkiotune&gt;</code></a>
        element, which applies globally to the domain).  Currently,
        the only tuning available is Block I/O throttling for qemu.
        This element has optional sub-elements; any sub-element not
        specified or given with a value of 0 implies no
        limit.  <span class="since">Since 0.9.8</span>
        <dl>
          <dt><code>total_bytes_sec</code></dt>
          <dd>The optional <code>total_bytes_sec</code> element is the
            total throughput limit in bytes per second.  This cannot
            appear with <code>read_bytes_sec</code>
            or <code>write_bytes_sec</code>.</dd>
          <dt><code>read_bytes_sec</code></dt>
          <dd>The optional <code>read_bytes_sec</code> element is the
            read throughput limit in bytes per second.</dd>
          <dt><code>write_bytes_sec</code></dt>
          <dd>The optional <code>write_bytes_sec</code> element is the
            write throughput limit in bytes per second.</dd>
          <dt><code>total_iops_sec</code></dt>
          <dd>The optional <code>total_iops_sec</code> element is the
            total I/O operations per second.  This cannot
            appear with <code>read_iops_sec</code>
            or <code>write_iops_sec</code>.</dd>
          <dt><code>read_iops_sec</code></dt>
          <dd>The optional <code>read_iops_sec</code> element is the
            read I/O operations per second.</dd>
          <dt><code>write_iops_sec</code></dt>
          <dd>The optional <code>write_iops_sec</code> element is the
            write I/O operations per second.</dd>
2225 2226 2227 2228 2229 2230 2231 2232 2233 2234 2235 2236 2237 2238 2239 2240 2241 2242 2243 2244 2245 2246 2247 2248 2249
          <dt><code>total_bytes_sec_max</code></dt>
          <dd>The optional <code>total_bytes_sec_max</code> element is the
            maximum total throughput limit in bytes per second.  This cannot
            appear with <code>read_bytes_sec_max</code>
            or <code>write_bytes_sec_max</code>.</dd>
          <dt><code>read_bytes_sec_max</code></dt>
          <dd>The optional <code>read_bytes_sec_max</code> element is the
            maximum read throughput limit in bytes per second.</dd>
          <dt><code>write_bytes_sec_max</code></dt>
          <dd>The optional <code>write_bytes_sec_max</code> element is the
            maximum write throughput limit in bytes per second.</dd>
          <dt><code>total_iops_sec_max</code></dt>
          <dd>The optional <code>total_iops_sec_max</code> element is the
            maximum total I/O operations per second.  This cannot
            appear with <code>read_iops_sec_max</code>
            or <code>write_iops_sec_max</code>.</dd>
          <dt><code>read_iops_sec_max</code></dt>
          <dd>The optional <code>read_iops_sec_max</code> element is the
            maximum read I/O operations per second.</dd>
          <dt><code>write_iops_sec_max</code></dt>
          <dd>The optional <code>write_iops_sec_max</code> element is the
            maximum write I/O operations per second.</dd>
          <dt><code>size_iops_sec</code></dt>
          <dd>The optional <code>size_iops_sec</code> element is the
            size of I/O operations per second.</dd>
L
Lei Li 已提交
2250
        </dl>
2251
      </dd>
D
Daniel P. Berrange 已提交
2252
      <dt><code>driver</code></dt>
M
Matthias Dahl 已提交
2253 2254 2255
      <dd>
        The optional driver element allows specifying further details
        related to the hypervisor driver used to provide the disk.
2256
        <span class="since">Since 0.1.8</span>
M
Matthias Dahl 已提交
2257 2258 2259 2260 2261 2262 2263 2264 2265 2266 2267 2268 2269 2270
        <ul>
          <li>
            If the hypervisor supports multiple backend drivers, then
            the <code>name</code> attribute selects the primary
            backend driver name, while the optional <code>type</code>
            attribute provides the sub-type.  For example, xen
            supports a name of "tap", "tap2", "phy", or "file", with a
            type of "aio", while qemu only supports a name of "qemu",
            but multiple types including "raw", "bochs", "qcow2", and
            "qed".
          </li>
          <li>
            The optional <code>cache</code> attribute controls the
            cache mechanism, possible values are "default", "none",
2271 2272 2273 2274 2275 2276 2277 2278 2279
            "writethrough", "writeback", "directsync" (like
            "writethrough", but it bypasses the host page cache) and
            "unsafe" (host may cache all disk io, and sync requests from
            guest are ignored).
            <span class="since">
              Since 0.6.0,
              "directsync" since 0.9.5,
              "unsafe" since 0.9.7
            </span>
M
Matthias Dahl 已提交
2280 2281 2282
          </li>
          <li>
            The optional <code>error_policy</code> attribute controls
2283 2284 2285 2286 2287 2288 2289
            how the hypervisor will behave on a disk read or write
            error, possible values are "stop", "report", "ignore", and
            "enospace".<span class="since">Since 0.8.0, "report" since
            0.9.7</span> The default setting of error_policy is "report".
            There is also an
            optional <code>rerror_policy</code> that controls behavior
            for read errors only. <span class="since">Since
E
Eric Blake 已提交
2290
            0.9.7</span>. If no rerror_policy is given, error_policy
2291 2292 2293 2294 2295 2296 2297
            is used for both read and write errors. If rerror_policy
            is given, it overrides the <code>error_policy</code> for
            read errors. Also note that "enospace" is not a valid
            policy for read errors, so if <code>error_policy</code> is
            set to "enospace" and no <code>rerror_policy</code> is
            given, the read error policy will be left at its default,
            which is "report".
M
Matthias Dahl 已提交
2298 2299 2300 2301
          </li>
          <li>
            The optional <code>io</code> attribute controls specific
            policies on I/O; qemu guests support "threads" and
2302
            "native". <span class="since">Since 0.8.8</span>
M
Matthias Dahl 已提交
2303
          </li>
2304 2305 2306 2307 2308 2309 2310 2311 2312 2313 2314 2315 2316 2317
          <li>
            The optional <code>ioeventfd</code> attribute allows users to
            set <a href='https://patchwork.kernel.org/patch/43390/'>
            domain I/O asynchronous handling</a> for disk device.
            The default is left to the discretion of the hypervisor.
            Accepted values are "on" and "off". Enabling this allows
            qemu to execute VM while a separate thread handles I/O.
            Typically guests experiencing high system CPU utilization
            during I/O will benefit from this. On the other hand,
            on overloaded host it could increase guest I/O latency.
            <span class="since">Since 0.9.3 (QEMU and KVM only)</span>
            <b>In general you should leave this option alone, unless you
            are very certain you know what you are doing.</b>
          </li>
2318 2319 2320 2321
          <li>
            The optional <code>event_idx</code> attribute controls
            some aspects of device event processing. The value can be
            either 'on' or 'off' - if it is on, it will reduce the
2322
            number of interrupts and exits for the guest. The default
2323 2324 2325 2326 2327 2328 2329 2330
            is determined by QEMU; usually if the feature is
            supported, default is on. In case there is a situation
            where this behavior is suboptimal, this attribute provides
            a way to force the feature off.
            <span class="since">Since 0.9.5 (QEMU and KVM only)</span>
            <b>In general you should leave this option alone, unless you
            are very certain you know what you are doing.</b>
          </li>
O
Osier Yang 已提交
2331 2332
          <li>
            The optional <code>copy_on_read</code> attribute controls
2333
            whether to copy read backing file into the image file. The
O
Osier Yang 已提交
2334 2335 2336 2337 2338 2339
            value can be either "on" or "off".
            Copy-on-read avoids accessing the same backing file sectors
            repeatedly and is useful when the backing file is over a slow
            network. By default copy-on-read is off.
            <span class='since'>Since 0.9.10 (QEMU and KVM only)</span>
          </li>
O
Osier Yang 已提交
2340 2341 2342 2343
          <li>
            The optional <code>discard</code> attribute controls whether
            to discard (also known as "trim" or "unmap") requests are
            ignored or passed to the filesystem. The value can be either
O
Osier Yang 已提交
2344 2345
            "unmap" (allow the discard request to be passed) or "ignore"
            (ignore the discard request).
O
Osier Yang 已提交
2346 2347
            <span class='since'>Since 1.0.6 (QEMU and KVM only)</span>
          </li>
2348 2349 2350 2351 2352 2353 2354 2355
          <li>
            The optional <code>iothread</code> attribute assigns the
            disk to an IOThread as defined by the range for the domain
            <a href="#elementsIOThreadsAllocation"><code>iothreads</code></a>
            value. Multiple devices may be assigned to the same IOThread and
            are numbered from 1 to the domain iothreads value.
            <span class='since'>Since 1.2.8 (QEMU only)</span>
          </li>
M
Matthias Dahl 已提交
2356
        </ul>
D
Daniel P. Berrange 已提交
2357
      </dd>
2358 2359 2360 2361 2362 2363 2364 2365
      <dt><code>boot</code></dt>
      <dd>Specifies that the disk is bootable. The <code>order</code>
        attribute determines the order in which devices will be tried during
        boot sequence. The per-device <code>boot</code> elements cannot be
        used together with general boot elements in
        <a href="#elementsOSBIOS">BIOS bootloader</a> section.
        <span class="since">Since 0.8.8</span>
      </dd>
2366 2367 2368 2369 2370
      <dt><code>encryption</code></dt>
      <dd>If present, specifies how the volume is encrypted.  See
        the <a href="formatstorageencryption.html">Storage Encryption</a> page
        for more information.
      </dd>
2371 2372 2373
      <dt><code>readonly</code></dt>
      <dd>If present, this indicates the device cannot be modified by
        the guest.  For now, this is the default for disks with
2374
        attribute <code>device='cdrom'</code>.
2375
      </dd>
2376 2377 2378 2379 2380
      <dt><code>shareable</code></dt>
      <dd>If present, this indicates the device is expected to be shared
          between domains (assuming the hypervisor and OS support this),
          which means that caching should be deactivated for that device.
      </dd>
2381 2382 2383 2384 2385 2386 2387
      <dt><code>transient</code></dt>
      <dd>If present, this indicates that changes to the device
        contents should be reverted automatically when the guest
        exits.  With some hypervisors, marking a disk transient
        prevents the domain from participating in migration or
        snapshots. <span class="since">Since 0.9.5</span>
      </dd>
2388 2389
      <dt><code>serial</code></dt>
      <dd>If present, this specify serial number of virtual hard drive.
E
Eric Blake 已提交
2390 2391
          For example, it may look
          like <code>&lt;serial&gt;WD-WMAP9A966149&lt;/serial&gt;</code>.
2392 2393
          <span class="since">Since 0.7.1</span>
      </dd>
O
Osier Yang 已提交
2394 2395 2396 2397 2398 2399
      <dt><code>wwn</code></dt>
      <dd>If present, this element specifies the WWN (World Wide Name)
        of a virtual hard disk or CD-ROM drive. It must be composed
        of 16 hexadecimal digits.
        <span class='since'>Since 0.10.1</span>
      </dd>
2400 2401 2402 2403 2404 2405 2406 2407 2408 2409 2410 2411
      <dt><code>vendor</code></dt>
      <dd>If present, this element specifies the vendor of a virtual hard
        disk or CD-ROM device. It must not be longer than 8 printable
        characters.
        <span class='since'>Since 1.0.1</span>
      </dd>
      <dt><code>product</code></dt>
      <dd>If present, this element specifies the product of a virtual hard
        disk or CD-ROM device. It must not be longer than 16 printable
        characters.
        <span class='since'>Since 1.0.1</span>
      </dd>
E
Eric Blake 已提交
2412 2413 2414 2415 2416 2417 2418 2419 2420
      <dt><code>address</code></dt>
      <dd>If present, the <code>address</code> element ties the disk
        to a given slot of a controller (the
        actual <code>&lt;controller&gt;</code> device can often be
        inferred by libvirt, although it can
        be <a href="#elementsControllers">explicitly specified</a>).
        The <code>type</code> attribute is mandatory, and is typically
        "pci" or "drive".  For a "pci" controller, additional
        attributes for <code>bus</code>, <code>slot</code>,
2421 2422 2423 2424 2425
        and <code>function</code> must be present, as well as
        optional <code>domain</code> and <code>multifunction</code>.
        Multifunction defaults to 'off'; any other value requires
        QEMU 0.1.3 and <span class="since">libvirt 0.9.7</span>.  For a
        "drive" controller, additional attributes
2426 2427 2428
        <code>controller</code>, <code>bus</code>, <code>target</code>
        (<span class="since">libvirt 0.9.11</span>), and <code>unit</code>
        are available, each defaulting to 0.
2429 2430
      </dd>
      <dt><code>auth</code></dt>
2431 2432 2433 2434
      <dd>The <code>auth</code> element is supported for a disk
        <code>type</code> "network" that is using a <code>source</code>
        element with the <code>protocol</code> attributes "rbd" or "iscsi".
        If present, the <code>auth</code> element provides the
2435 2436 2437 2438 2439 2440 2441 2442
        authentication credentials needed to access the source.  It
        includes a mandatory attribute <code>username</code>, which
        identifies the username to use during authentication, as well
        as a sub-element <code>secret</code> with mandatory
        attribute <code>type</code>, to tie back to
        a <a href="formatsecret.html">libvirt secret object</a> that
        holds the actual password or other credentials (the domain XML
        intentionally does not expose the password, only the reference
2443 2444 2445 2446 2447
        to the object that does manage the password).
        Known secret types are "ceph" for Ceph RBD network sources and
        "iscsi" for CHAP authentication of iSCSI targets.
        Both will require either a <code>uuid</code> attribute
        with the UUID of the secret object or a <code>usage</code>
2448 2449
        attribute matching the key that was specified in the
        secret object.  <span class="since">libvirt 0.9.7</span>
E
Eric Blake 已提交
2450
      </dd>
J
J.B. Joret 已提交
2451 2452 2453 2454 2455 2456 2457 2458 2459 2460 2461 2462 2463 2464 2465 2466 2467 2468 2469
      <dt><code>geometry</code></dt>
      <dd>The optional <code>geometry</code> element provides the
        ability to override geometry settings. This mostly useful for
        S390 DASD-disks or older DOS-disks.  <span class="since">0.10.0</span>
        <dl>
          <dt><code>cyls</code></dt>
          <dd>The <code>cyls</code> attribute is the
            number of cylinders. </dd>
          <dt><code>heads</code></dt>
          <dd>The <code>heads</code> attribute is the
            number of heads. </dd>
          <dt><code>secs</code></dt>
          <dd>The <code>secs</code> attribute is the
            number of sectors per track. </dd>
          <dt><code>trans</code></dt>
          <dd>The optional <code>trans</code> attribute is the
            BIOS-Translation-Modus (none, lba or auto)</dd>
        </dl>
      </dd>
V
Viktor Mihajlovski 已提交
2470 2471
      <dt><code>blockio</code></dt>
      <dd>If present, the <code>blockio</code> element allows
2472 2473 2474 2475 2476 2477 2478 2479
        to override any of the block device properties listed below.
        <span class="since">Since 0.10.2 (QEMU and KVM)</span>
        <dl>
          <dt><code>logical_block_size</code></dt>
          <dd>The logical block size the disk will report to the guest
            OS. For Linux this would be the value returned by the
            BLKSSZGET ioctl and describes the smallest units for disk
            I/O.
2480
          </dd>
2481 2482 2483 2484 2485
          <dt><code>physical_block_size</code></dt>
          <dd>The physical block size the disk will report to the guest
            OS. For Linux this would be the value returned by the
            BLKPBSZGET ioctl and describes the disk's hardware sector
            size which can be relevant for the alignment of disk data.
2486
          </dd>
2487 2488
        </dl>
      </dd>
D
Daniel P. Berrange 已提交
2489 2490
    </dl>

2491 2492 2493 2494 2495 2496 2497 2498 2499 2500 2501 2502 2503 2504
    <h4><a name="elementsFilesystems">Filesystems</a></h4>

    <p>
      A directory on the host that can be accessed directly from the guest.
      <span class="since">since 0.3.3, since 0.8.5 for QEMU/KVM</span>
    </p>

<pre>
  ...
  &lt;devices&gt;
    &lt;filesystem type='template'&gt;
      &lt;source name='my-vm-template'/&gt;
      &lt;target dir='/'/&gt;
    &lt;/filesystem&gt;
2505
    &lt;filesystem type='mount' accessmode='passthrough'&gt;
2506
      &lt;driver type='path' wrpolicy='immediate'/&gt;
2507 2508 2509 2510
      &lt;source dir='/export/to/guest'/&gt;
      &lt;target dir='/import/from/host'/&gt;
      &lt;readonly/&gt;
    &lt;/filesystem&gt;
2511 2512 2513 2514 2515 2516 2517
    &lt;filesystem type='file' accessmode='passthrough'&gt;
      &lt;driver name='loop' type='raw'/&gt;
      &lt;driver type='path' wrpolicy='immediate'/&gt;
      &lt;source file='/export/to/guest.img'/&gt;
      &lt;target dir='/import/from/host'/&gt;
      &lt;readonly/&gt;
    &lt;/filesystem&gt;
2518 2519 2520 2521 2522 2523 2524 2525 2526 2527 2528 2529 2530 2531 2532 2533 2534
    ...
  &lt;/devices&gt;
  ...</pre>

    <dl>
      <dt><code>filesystem</code></dt>
      <dd>

      The filesystem attribute <code>type</code> specifies the type of the
      <code>source</code>. The possible values are:

        <dl>
        <dt><code>type='mount'</code></dt>
        <dd>
        A host directory to mount in the guest. Used by LXC,
        OpenVZ <span class="since">(since 0.6.2)</span>
        and QEMU/KVM <span class="since">(since 0.8.5)</span>.
2535
        This is the default <code>type</code> if one is not specified.
2536 2537 2538 2539
        This mode also has an optional
        sub-element <code>driver</code>, with an
        attribute <code>type='path'</code>
        or <code>type='handle'</code> <span class="since">(since
2540 2541 2542 2543 2544 2545
        0.9.7)</span>. The driver block has an optional attribute
        <code>wrpolicy</code> that further controls interaction with
        the host page cache; omitting the attribute gives default behavior,
        while the value <code>immediate</code> means that a host writeback
        is immediately triggered for all pages touched during a guest file
        write operation <span class="since">(since 0.9.10)</span>.
2546 2547 2548 2549 2550 2551 2552
        </dd>
        <dt><code>type='template'</code></dt>
        <dd>
        OpenVZ filesystem template. Only used by OpenVZ driver.
        </dd>
        <dt><code>type='file'</code></dt>
        <dd>
2553 2554 2555
        A host file will be treated as an image and mounted in
        the guest. The filesystem format will be autodetected.
        Only used by LXC driver.
2556 2557 2558
        </dd>
        <dt><code>type='block'</code></dt>
        <dd>
2559 2560 2561
        A host block device to mount in the guest. The filesystem
        format will be autodetected. Only used by LXC driver
        <span class="since">(since 0.9.5)</span>.
2562
        </dd>
2563 2564 2565 2566
        <dt><code>type='ram'</code></dt>
        <dd>
          An in-memory filesystem, using memory from the host OS.
          The source element has a single attribute <code>usage</code>
2567 2568
          which gives the memory usage limit in KiB, unless units
          are specified by the <code>units</code> attribute. Only used
2569 2570
          by LXC driver.
          <span class="since"> (since 0.9.13)</span></dd>
E
Eric Blake 已提交
2571
        <dt><code>type='bind'</code></dt>
2572 2573 2574 2575
        <dd>
          A directory inside the guest will be bound to another
          directory inside the guest. Only used by LXC driver
          <span class="since"> (since 0.9.13)</span></dd>
2576 2577
        </dl>

2578
      The filesystem block has an optional attribute <code>accessmode</code>
2579 2580 2581 2582 2583 2584
      which specifies the security mode for accessing the source
      <span class="since">(since 0.8.5)</span>. Currently this only works
      with <code>type='mount'</code> for the QEMU/KVM driver. The possible
      values are:

        <dl>
2585
        <dt><code>accessmode='passthrough'</code></dt>
2586 2587
        <dd>
        The <code>source</code> is accessed with the permissions of the
2588
        user inside the guest. This is the default <code>accessmode</code> if
2589 2590 2591
        one is not specified.
        <a href="http://lists.gnu.org/archive/html/qemu-devel/2010-05/msg02673.html">More info</a>
        </dd>
2592
        <dt><code>accessmode='mapped'</code></dt>
2593 2594 2595 2596 2597
        <dd>
        The <code>source</code> is accessed with the permissions of the
        hypervisor (QEMU process).
        <a href="http://lists.gnu.org/archive/html/qemu-devel/2010-05/msg02673.html">More info</a>
        </dd>
2598
        <dt><code>accessmode='squash'</code></dt>
2599 2600 2601 2602 2603 2604 2605 2606 2607 2608 2609
        <dd>
        Similar to 'passthrough', the exception is that failure of
        privileged operations like 'chown' are ignored. This makes a
        passthrough-like mode usable for people who run the hypervisor
        as non-root.
        <a href="http://lists.gnu.org/archive/html/qemu-devel/2010-09/msg00121.html">More info</a>
        </dd>
        </dl>

      </dd>

2610 2611 2612 2613 2614 2615 2616 2617 2618 2619 2620
      <dt><code>driver</code></dt>
      <dd>
        The optional driver element allows specifying further details
        related to the hypervisor driver used to provide the filesystem.
        <span class="since">Since 1.0.6</span>
        <ul>
          <li>
            If the hypervisor supports multiple backend drivers, then
            the <code>type</code> attribute selects the primary
            backend driver name, while the <code>format</code>
            attribute provides the format type. For example, LXC
2621 2622 2623
            supports a type of "loop", with a format of "raw" or
            "nbd" with any format. QEMU supports a type of "path"
            or "handle", but no formats.
2624 2625 2626 2627
          </li>
        </ul>
      </dd>

2628 2629 2630 2631 2632
      <dt><code>source</code></dt>
      <dd>
        The resource on the host that is being accessed in the guest. The
        <code>name</code> attribute must be used with
        <code>type='template'</code>, and the <code>dir</code> attribute must
2633
        be used with <code>type='mount'</code>. The <code>usage</code> attribute
2634 2635
        is used with <code>type='ram'</code> to set the memory limit in KiB,
        unless units are specified by the <code>units</code> attribute.
2636 2637 2638 2639 2640 2641 2642 2643 2644 2645 2646 2647
      </dd>

      <dt><code>target</code></dt>
      <dd>
        Where the <code>source</code> can be accessed in the guest. For
        most drivers this is an automatic mount point, but for QEMU/KVM
        this is merely an arbitrary string tag that is exported to the
        guest as a hint for where to mount.
      </dd>

      <dt><code>readonly</code></dt>
      <dd>
2648
        Enables exporting filesystem as a readonly mount for guest, by
2649 2650
        default read-write access is given (currently only works for
        QEMU/KVM driver).
2651
      </dd>
2652 2653 2654 2655 2656 2657 2658 2659 2660 2661 2662 2663 2664 2665

      <dt><code>space_hard_limit</code></dt>
      <dd>
        Maximum space available to this guest's filesystem.
        <span class="since">Since 0.9.13</span>
      </dd>

      <dt><code>space_soft_limit</code></dt>
      <dd>
        Maximum space available to this guest's filesystem. The container is
        permitted to exceed its soft limits for a grace period of time. Afterwards the
        hard limit is enforced.
        <span class="since">Since 0.9.13</span>
      </dd>
2666 2667
    </dl>

2668 2669 2670 2671 2672 2673 2674 2675 2676 2677 2678 2679 2680 2681 2682 2683 2684 2685 2686
    <h4><a name="elementsAddress">Device Addresses</a></h4>

    <p>
      Many devices have an optional <code>&lt;address&gt;</code>
      sub-element to describe where the device is placed on the
      virtual bus presented to the guest.  If an address (or any
      optional attribute within an address) is omitted on
      input, libvirt will generate an appropriate address; but an
      explicit address is required if more control over layout is
      required.  See below for device examples including an address
      element.
    </p>

    <p>
      Every address has a mandatory attribute <code>type</code> that
      describes which bus the device is on.  The choice of which
      address to use for a given device is constrained in part by the
      device and the architecture of the guest.  For example,
      a <code>&lt;disk&gt;</code> device
2687
      uses <code>type='drive'</code>, while
2688 2689 2690 2691 2692 2693 2694 2695 2696 2697 2698 2699 2700 2701 2702 2703 2704 2705 2706 2707 2708 2709 2710 2711 2712 2713 2714
      a <code>&lt;console&gt;</code> device would
      use <code>type='pci'</code> on i686 or x86_64 guests,
      or <code>type='spapr-vio'</code> on PowerPC64 pseries guests.
      Each address type has further optional attributes that control
      where on the bus the device will be placed:
    </p>

    <dl>
      <dt><code>type='pci'</code></dt>
      <dd>PCI addresses have the following additional
        attributes: <code>domain</code> (a 2-byte hex integer, not
        currently used by qemu), <code>bus</code> (a hex value between
        0 and 0xff, inclusive), <code>slot</code> (a hex value between
        0x0 and 0x1f, inclusive), and <code>function</code> (a value
        between 0 and 7, inclusive).  Also available is
        the <code>multifunction</code> attribute, which controls
        turning on the multifunction bit for a particular
        slot/function in the PCI control register
        (<span class="since">since 0.9.7, requires QEMU
        0.13</span>). <code>multifunction</code> defaults to 'off',
        but should be set to 'on' for function 0 of a slot that will
        have multiple functions used.
      </dd>
      <dt><code>type='drive'</code></dt>
      <dd>Drive addresses have the following additional
        attributes: <code>controller</code> (a 2-digit controller
        number), <code>bus</code> (a 2-digit bus number),
2715
        <code>target</code> (a 2-digit bus number),
2716 2717 2718 2719 2720 2721 2722 2723 2724 2725 2726 2727 2728
        and <code>unit</code> (a 2-digit unit number on the bus).
      </dd>
      <dt><code>type='virtio-serial'</code></dt>
      <dd>Each virtio-serial address has the following additional
        attributes: <code>controller</code> (a 2-digit controller
        number), <code>bus</code> (a 2-digit bus number),
        and <code>slot</code> (a 2-digit slot within the bus).
      </dd>
      <dt><code>type='ccid'</code></dt>
      <dd>A CCID address, for smart-cards, has the following
        additional attributes: <code>bus</code> (a 2-digit bus
        number), and <code>slot</code> attribute (a 2-digit slot
        within the bus).  <span class="since">Since 0.8.8.</span>
2729
      </dd>
2730 2731 2732 2733 2734 2735 2736 2737 2738 2739 2740 2741 2742 2743 2744
      <dt><code>type='usb'</code></dt>
      <dd>USB addresses have the following additional
        attributes: <code>bus</code> (a hex value between 0 and 0xfff,
        inclusive), and <code>port</code> (a dotted notation of up to
        four octets, such as 1.2 or 2.1.3.1).
      </dd>
      <dt><code>type='spapr-vio'</code></dt>
      <dd>On PowerPC pseries guests, devices can be assigned to the
        SPAPR-VIO bus.  It has a flat 64-bit address space; by
        convention, devices are generally assigned at a non-zero
        multiple of 0x1000, but other addresses are valid and
        permitted by libvirt.  Each address has the following
        additional attribute: <code>reg</code> (the hex value address
        of the starting register).  <span class="since">Since
        0.9.9.</span>
2745 2746 2747 2748 2749 2750 2751 2752 2753 2754 2755 2756 2757 2758
      </dd>
      <dt><code>type='ccw'</code></dt>
      <dd>s390 guests with a <code>machine</code> value of
        s390-ccw-virtio use the native CCW bus for I/O devices.
        CCW bus addresses have the following additional attributes:
        <code>cssid</code> (a hex value between 0 and 0xfe, inclusive),
        <code>ssid</code> (a value between 0 and 3, inclusive) and
        <code>devno</code> (a hex value between 0 and 0xffff, inclusive).
        Partially specified bus addresses are not allowed.
        If omitted, libvirt will assign a free bus address with
        cssid=0xfe and ssid=0. Virtio devices for s390 must have their
        cssid set to 0xfe in order to be recognized by the guest
        operating system.
        <span class="since">Since 1.0.4</span>
2759
      </dd>
H
Hu Tao 已提交
2760 2761 2762 2763 2764
      <dt><code>type='isa'</code></dt>
      <dd>ISA addresses have the following additional
        attributes: <code>iobase</code> and <code>irq</code>.
        <span class="since">Since 1.2.1</span>
      </dd>
2765 2766
    </dl>

E
Eric Blake 已提交
2767 2768 2769
    <h4><a name="elementsControllers">Controllers</a></h4>

    <p>
2770
      Depending on the guest architecture, some device buses can
2771 2772
      appear more than once, with a group of virtual devices tied to a
      virtual controller.  Normally, libvirt can automatically infer such
E
Eric Blake 已提交
2773 2774 2775 2776 2777 2778 2779 2780 2781 2782 2783 2784 2785 2786 2787 2788 2789 2790
      controllers without requiring explicit XML markup, but sometimes
      it is necessary to provide an explicit controller element.
    </p>

<pre>
  ...
  &lt;devices&gt;
    &lt;controller type='ide' index='0'/&gt;
    &lt;controller type='virtio-serial' index='0' ports='16' vectors='4'/&gt;
    &lt;controller type='virtio-serial' index='1'&gt;
      &lt;address type='pci' domain='0x0000' bus='0x00' slot='0x0a' function='0x0'/&gt;
    &lt;/controller&gt;
    ...
  &lt;/devices&gt;
  ...</pre>

    <p>
      Each controller has a mandatory attribute <code>type</code>,
2791
      which must be one of "ide", "fdc", "scsi", "sata", "usb",
J
Ján Tomko 已提交
2792
      "ccid", "virtio-serial" or "pci", and a mandatory
2793 2794 2795 2796 2797
      attribute <code>index</code> which is the decimal integer
      describing in which order the bus controller is encountered (for
      use in <code>controller</code> attributes
      of <code>&lt;address&gt;</code> elements).  The "virtio-serial"
      controller has two additional optional
E
Eric Blake 已提交
2798 2799 2800
      attributes <code>ports</code> and <code>vectors</code>, which
      control how many devices can be connected through the
      controller.  A "scsi" controller has an optional
2801
      attribute <code>model</code>, which is one of "auto", "buslogic",
2802
      "ibmvscsi", "lsilogic", "lsisas1068", "lsisas1078", "virtio-scsi" or
2803 2804 2805 2806 2807 2808
      "vmpvscsi".  A "usb" controller has an optional attribute
      <code>model</code>, which is one of "piix3-uhci", "piix4-uhci", "ehci",
      "ich9-ehci1", "ich9-uhci1", "ich9-uhci2", "ich9-uhci3", "vt82c686b-uhci",
      "pci-ohci" or "nec-xhci".  Additionally,
      <span class="since">since 0.10.0</span>, if the USB bus needs to be
      explicitly disabled for the guest, <code>model='none'</code> may be
2809 2810 2811
      used.  <span class="since">Since 1.0.5</span>, no default USB controller
      will be built on s390.  The PowerPC64 "spapr-vio" addresses do not have an
      associated controller.
E
Eric Blake 已提交
2812 2813 2814 2815 2816 2817
    </p>

    <p>
      For controllers that are themselves devices on a PCI or USB bus,
      an optional sub-element <code>&lt;address&gt;</code> can specify
      the exact relationship of the controller to its master bus, with
2818
      semantics <a href="#elementsAddress">given above</a>.
E
Eric Blake 已提交
2819 2820
    </p>

2821 2822
    <p>
      An optional sub-element <code>driver</code> can specify the driver
2823
      specific options:
2824
    </p>
2825 2826 2827 2828 2829 2830 2831 2832 2833 2834 2835 2836 2837 2838 2839 2840 2841 2842 2843 2844 2845 2846 2847 2848
    <dl>
      <dt><code>queues</code></dt>
      <dd>
        The optional <code>queues</code> attribute specifies the number of
        queues for the controller. For best performance, it's recommended to
        specify a value matching the number of vCPUs.
        <span class="since">Since 1.0.5 (QEMU and KVM only)</span>
      </dd>
      <dt><code>cmd_per_lun</code></dt>
      <dd>
        The optional <code>cmd_per_lun</code> attribute specifies the maximum
        number of commands that can be queued on devices controlled by the
        host.
        <span class="since">Since 1.2.7 (QEMU and KVM only)</span>
      </dd>
      <dt><code>max_sectors</code></dt>
      <dd>
        The optional <code>max_sectors</code> attribute specifies the maximum
        amount of data in bytes that will be transferred to or from the device
        in a single command. The transfer length is measured in sectors, where
        a sector is 512 bytes.
        <span class="since">Since 1.2.7 (QEMU and KVM only)</span>
      </dd>
    </dl>
2849 2850 2851 2852 2853 2854 2855 2856 2857 2858 2859 2860 2861 2862 2863 2864
    <p>
      USB companion controllers have an optional
      sub-element <code>&lt;master&gt;</code> to specify the exact
      relationship of the companion to its master controller.
      A companion controller is on the same bus as its master, so
      the companion <code>index</code> value should be equal.
    </p>

<pre>
  ...
  &lt;devices&gt;
    &lt;controller type='usb' index='0' model='ich9-ehci1'&gt;
      &lt;address type='pci' domain='0' bus='0' slot='4' function='7'/&gt;
    &lt;/controller&gt;
    &lt;controller type='usb' index='0' model='ich9-uhci1'&gt;
      &lt;master startport='0'/&gt;
2865
      &lt;address type='pci' domain='0' bus='0' slot='4' function='0' multifunction='on'/&gt;
2866 2867 2868
    &lt;/controller&gt;
    ...
  &lt;/devices&gt;
J
Ján Tomko 已提交
2869 2870 2871 2872
  ...</pre>

    <p>
      PCI controllers have an optional <code>model</code> attribute with
2873 2874
      possible values <code>pci-root</code>, <code>pcie-root</code>,
      <code>pci-bridge</code>, or <code>dmi-to-pci-bridge</code>.
2875 2876 2877 2878 2879 2880 2881 2882 2883
      The root controllers (<code>pci-root</code> and <code>pcie-root</code>)
      have an optional <code>pcihole64</code> element specifying how big
      (in kilobytes, or in the unit specified by <code>pcihole64</code>'s
      <code>unit</code> attribute) the 64-bit PCI hole should be. Some guests (like
      Windows XP or Windows Server 2003) might crash when QEMU and Seabios
      are recent enough to support 64-bit PCI holes, unless this is disabled
      (set to 0). <span class="since">Since 1.1.2 (QEMU only)</span>
    </p>
    <p>
L
Laine Stump 已提交
2884
      For machine types which provide an implicit PCI bus, the pci-root
J
Ján Tomko 已提交
2885
      controller with index=0 is auto-added and required to use PCI devices.
L
Laine Stump 已提交
2886
      pci-root has no address.
2887 2888 2889
      PCI bridges are auto-added if there are too many devices to fit on
      the one bus provided by pci-root, or a PCI bus number greater than zero
      was specified.
J
Ján Tomko 已提交
2890 2891 2892 2893
      PCI bridges can also be specified manually, but their addresses should
      only refer to PCI buses provided by already specified PCI controllers.
      Leaving gaps in the PCI controller indexes might lead to an invalid
      configuration.
L
Laine Stump 已提交
2894
      (pci-root and pci-bridge <span class="since">since 1.0.5</span>)
J
Ján Tomko 已提交
2895 2896 2897 2898 2899 2900
    </p>
<pre>
  ...
  &lt;devices&gt;
    &lt;controller type='pci' index='0' model='pci-root'/&gt;
    &lt;controller type='pci' index='1' model='pci-bridge'&gt;
L
Laine Stump 已提交
2901
      &lt;address type='pci' domain='0' bus='0' slot='5' function='0' multifunction='off'/&gt;
J
Ján Tomko 已提交
2902 2903
    &lt;/controller&gt;
  &lt;/devices&gt;
L
Laine Stump 已提交
2904 2905 2906 2907 2908 2909 2910 2911
  ...</pre>

    <p>
      For machine types which provide an implicit PCI Express (PCIe)
      bus (for example, the machine types based on the Q35 chipset),
      the pcie-root controller with index=0 is auto-added to the
      domain's configuration. pcie-root has also no address, provides
      31 slots (numbered 1-31) and can only be used to attach PCIe
2912 2913 2914 2915 2916 2917 2918 2919 2920 2921 2922 2923
      devices. In order to connect standard PCI devices on a system
      which has a pcie-root controller, a pci controller
      with <code>model='dmi-to-pci-bridge'</code> is automatically
      added. A dmi-to-pci-bridge controller plugs into a PCIe slot (as
      provided by pcie-root), and itself provides 31 standard PCI
      slots (which are not hot-pluggable). In order to have
      hot-pluggable PCI slots in the guest system, a pci-bridge
      controller will also be automatically created and connected to
      one of the slots of the auto-created dmi-to-pci-bridge
      controller; all guest devices with PCI addresses that are
      auto-determined by libvirt will be placed on this pci-bridge
      device.  (<span class="since">since 1.1.2</span>).
L
Laine Stump 已提交
2924 2925 2926 2927 2928
    </p>
<pre>
  ...
  &lt;devices&gt;
    &lt;controller type='pci' index='0' model='pcie-root'/&gt;
2929 2930 2931 2932 2933 2934
    &lt;controller type='pci' index='1' model='dmi-to-pci-bridge'&gt;
      &lt;address type='pci' domain='0' bus='0' slot='0xe' function='0'/&gt;
    &lt;/controller&gt;
    &lt;controller type='pci' index='2' model='pci-bridge'&gt;
      &lt;address type='pci' domain='0' bus='1' slot='1' function='0'/&gt;
    &lt;/controller&gt;
L
Laine Stump 已提交
2935
  &lt;/devices&gt;
2936 2937
  ...</pre>

2938 2939 2940 2941 2942 2943 2944 2945 2946 2947 2948 2949 2950 2951 2952 2953 2954 2955 2956 2957 2958 2959 2960 2961 2962 2963 2964 2965 2966 2967 2968 2969 2970 2971 2972 2973 2974 2975 2976
    <h4><a name="elementsLease">Device leases</a></h4>

    <p>
      When using a lock manager, it may be desirable to record device leases
      against a VM. The lock manager will ensure the VM won't start unless
      the leases can be acquired.
    </p>

<pre>
  ...
  &lt;devices&gt;
    ...
    &lt;lease&gt;
      &lt;lockspace&gt;somearea&lt;/lockspace&gt;
      &lt;key&gt;somekey&lt;/key&gt;
      &lt;target path='/some/lease/path' offset='1024'/&gt;
    &lt;/lease&gt;
    ...
  &lt;/devices&gt;
  ...</pre>

    <dl>
      <dt>lockspace</dt>
      <dd>This is an arbitrary string, identifying the lockspace
        within which the key is held. Lock managers may impose
        extra restrictions on the format, or length of the lockspace
        name.</dd>
      <dt>key</dt>
      <dd>This is an arbitrary string, uniquely identifying the
        lease to be acquired. Lock managers may impose extra
        restrictions on the format, or length of the key.
      </dd>
      <dt>target</dt>
      <dd>This is the fully qualified path of the file associated
        with the lockspace. The offset specifies where the lease
        is stored within the file. If the lock manager does not
        require a offset, just pass 0.
      </dd>
    </dl>
E
Eric Blake 已提交
2977

2978 2979
    <h4><a name="elementsHostDev">Host device assignment</a></h4>

2980
    <h5><a name="elementsHostDevSubsys">USB / PCI / SCSI devices</a></h5>
2981 2982

    <p>
H
Han Cheng 已提交
2983
      USB, PCI and SCSI devices attached to the host can be passed through
2984
      to the guest using the <code>hostdev</code> element.
H
Han Cheng 已提交
2985 2986
      <span class="since">since after 0.4.4 for USB, 0.6.0 for PCI(KVM only)
        and 1.0.6 for SCSI(KVM only)</span>:
2987 2988
    </p>

2989 2990 2991 2992
<pre>
  ...
  &lt;devices&gt;
    &lt;hostdev mode='subsystem' type='usb'&gt;
2993
      &lt;source startupPolicy='optional'&gt;
2994 2995 2996
        &lt;vendor id='0x1234'/&gt;
        &lt;product id='0xbeef'/&gt;
      &lt;/source&gt;
2997
      &lt;boot order='2'/&gt;
2998 2999 3000 3001
    &lt;/hostdev&gt;
  &lt;/devices&gt;
  ...</pre>

3002
    <p>or:</p>
3003 3004 3005 3006

<pre>
  ...
  &lt;devices&gt;
3007
    &lt;hostdev mode='subsystem' type='pci' managed='yes'&gt;
3008
      &lt;source&gt;
3009
        &lt;address domain='0x0000' bus='0x06' slot='0x02' function='0x0'/&gt;
3010
      &lt;/source&gt;
3011
      &lt;boot order='1'/&gt;
3012
      &lt;rom bar='on' file='/etc/fake/boot.bin'/&gt;
3013 3014
    &lt;/hostdev&gt;
  &lt;/devices&gt;
H
Han Cheng 已提交
3015 3016 3017 3018 3019 3020 3021
  ...</pre>

    <p>or:</p>

<pre>
  ...
  &lt;devices&gt;
3022
    &lt;hostdev mode='subsystem' type='scsi' sgio='filtered' rawio='yes'&gt;
H
Han Cheng 已提交
3023 3024 3025 3026 3027 3028 3029 3030
      &lt;source&gt;
        &lt;adapter name='scsi_host0'/&gt;
        &lt;address type='scsi' bus='0' target='0' unit='0'/&gt;
      &lt;/source&gt;
      &lt;readonly/&gt;
      &lt;address type='drive' controller='0' bus='0' target='0' unit='0'/&gt;
    &lt;/hostdev&gt;
  &lt;/devices&gt;
3031
  ...</pre>
3032

J
John Ferlan 已提交
3033 3034 3035 3036 3037 3038 3039 3040 3041 3042 3043 3044 3045 3046 3047 3048 3049 3050

    <p>or:</p>

<pre>
  ...
  &lt;devices&gt;
    &lt;hostdev mode='subsystem' type='scsi'&gt;
      &lt;source protocol='iscsi' name='iqn.2014-08.com.example:iscsi-nopool/1'&gt;
        &lt;host name='example.com' port='3260'/&gt;
        &lt;auth username='myuser'&gt;
          &lt;secret type='iscsi' usage='libvirtiscsi'/&gt;
        &lt;/auth&gt;
      &lt;/source&gt;
      &lt;address type='drive' controller='0' bus='0' target='0' unit='0'/&gt;
    &lt;/hostdev&gt;
  &lt;/devices&gt;
  ...</pre>

3051 3052 3053
    <dl>
      <dt><code>hostdev</code></dt>
      <dd>The <code>hostdev</code> element is the main container for describing
J
John Ferlan 已提交
3054 3055 3056 3057 3058 3059 3060 3061 3062 3063 3064 3065 3066 3067 3068 3069 3070 3071 3072 3073 3074 3075 3076 3077 3078 3079 3080
        host devices. For each device, the <code>mode</code> is always
        "subsystem" and the <code>type</code> is one of the following values
        with additional attributes noted.
        <dl>
          <dt>usb</dt>
          <dd>For USB devices, the user is responsible to call
            <code>virNodeDeviceDettach</code> (or
            <code>virsh nodedev-detach</code>) before starting the guest
            or hot-plugging the device and <code>virNodeDeviceReAttach</code>
            (or <code>virsh nodedev-reattach</code>) after hot-unplug or
            stopping the guest.
          </dd>
          <dt>pci</dt>
          <dd>For PCI devices, when <code>managed</code> is "yes" it is
            detached from the host before being passed on to the guest
            and reattached to the host after the guest exits. If
            <code>managed</code> is omitted or "no", follow the steps
            described for a USB device to detach before starting the
            guest or hot-plugging and reattach after stopping the guest
            or hot-unplug.
          </dd>
          <dt>scsi</dt>
          <dd>For SCSI devices, user is responsible to make sure the device
            is not used by host. The optional <code>sgio</code>
            (<span class="since">since 1.0.6</span>) attribute indicates
            whether the kernel will filter unprivileged SG_IO commands for
            the disk, valid settings are "filtered" or "unfiltered".
3081 3082 3083 3084 3085 3086 3087
            The default is "filtered". The optional <code>rawio</code>
            (<span class="since">since 1.2.9</span>) attribute indicates
            whether the lun needs the rawio capability. Valid settings are
            "yes" or "no". See the rawio description within the
            <a href="#elementsDisks">disk</a> section.
            If a disk lun in the domain already has the rawio capability,
            then this setting not required.
J
John Ferlan 已提交
3088 3089
          </dd>
        </dl>
O
Osier Yang 已提交
3090
      </dd>
3091
      <dt><code>source</code></dt>
J
John Ferlan 已提交
3092 3093 3094 3095 3096 3097 3098 3099 3100 3101 3102 3103 3104 3105 3106 3107 3108 3109 3110 3111 3112 3113 3114 3115 3116 3117 3118 3119 3120 3121 3122 3123 3124 3125 3126 3127 3128 3129 3130 3131 3132 3133 3134 3135 3136 3137 3138 3139
      <dd>The source element describes the device as seen from the host using
        the following mechanism to describe:
        <dl>
          <dt>usb</dt>
          <dd>The USB device can either be addressed by vendor / product id
            using the <code>vendor</code> and <code>product</code> elements
            or by the device's address on the host using the
            <code>address</code> element.
            <p>
            <span class="since">Since 1.0.0</span>, the <code>source</code>
            element of USB devices may contain <code>startupPolicy</code>
            attribute which can be used to define policy what to do if the
            specified host USB device is not found. The attribute accepts
            the following values:
            </p>
            <table class="top_table">
              <tr>
                <td> mandatory </td>
                <td> fail if missing for any reason (the default) </td>
              </tr>
              <tr>
                <td> requisite </td>
                <td> fail if missing on boot up,
                     drop if missing on migrate/restore/revert </td>
              </tr>
              <tr>
                <td> optional </td>
                <td> drop if missing at any start attempt </td>
              </tr>
            </table>
          </dd>
          <dt>pci</dt>
          <dd>PCI devices can only be described by their <code>address</code>.
          </dd>
          <dt>scsi</dt>
          <dd>SCSI devices are described by both the <code>adapter</code>
            and <code>address</code> elements.
            <p>
            <span class="since">Since 1.2.8</span>, the <code>source</code>
            element of a SCSI device may contain the <code>protocol</code>
            attribute. When the attribute is set to "iscsi", the host
            device XML follows the network <a href="#elementsDisks">disk</a>
            device using the same <code>name</code> attribute and optionally
            using the <code>auth</code> element to provide the authentication
            credentials to the iSCSI server.
            </p>
          </dd>
        </dl>
3140
      </dd>
3141 3142 3143 3144 3145
      <dt><code>vendor</code>, <code>product</code></dt>
      <dd>The <code>vendor</code> and <code>product</code> elements each have an
      <code>id</code> attribute that specifies the USB vendor and product id.
      The ids can be given in decimal, hexadecimal (starting with 0x) or
      octal (starting with 0) form.</dd>
3146 3147 3148 3149 3150 3151
      <dt><code>boot</code></dt>
      <dd>Specifies that the device is bootable. The <code>order</code>
      attribute determines the order in which devices will be tried during
      boot sequence. The per-device <code>boot</code> elements cannot be
      used together with general boot elements in
      <a href="#elementsOSBIOS">BIOS bootloader</a> section.
3152 3153
      <span class="since">Since 0.8.8</span> for PCI devices,
      <span class="since">Since 1.0.1</span> for USB devices.
3154
      </dd>
3155 3156
      <dt><code>rom</code></dt>
      <dd>The <code>rom</code> element is used to change how a PCI
3157
        device's ROM is presented to the guest. The optional <code>bar</code>
3158 3159 3160 3161 3162 3163 3164
        attribute can be set to "on" or "off", and determines whether
        or not the device's ROM will be visible in the guest's memory
        map. (In PCI documentation, the "rombar" setting controls the
        presence of the Base Address Register for the ROM). If no rom
        bar is specified, the qemu default will be used (older
        versions of qemu used a default of "off", while newer qemus
        have a default of "on"). <span class="since">Since
3165 3166 3167 3168 3169 3170 3171
        0.9.7 (QEMU and KVM only)</span>. The optional
        <code>file</code> attribute is used to point to a binary file
        to be presented to the guest as the device's ROM BIOS. This
        can be useful, for example, to provide a PXE boot ROM for a
        virtual function of an sr-iov capable ethernet device (which
        has no boot ROMs for the VFs).
        <span class="since">Since 0.9.10 (QEMU and KVM only)</span>.
3172
      </dd>
3173
      <dt><code>address</code></dt>
3174 3175 3176 3177 3178
      <dd>The <code>address</code> element for USB devices has a
      <code>bus</code> and <code>device</code> attribute to specify the
      USB bus and device number the device appears at on the host.
      The values of these attributes can be given in decimal, hexadecimal
      (starting with 0x) or octal (starting with 0) form.
3179
      For PCI devices the element carries 4 attributes allowing to designate
3180
      the device as can be found with the <code>lspci</code> or
3181 3182
      with <code>virsh
      nodedev-list</code>. <a href="#elementsAddress">See above</a> for
3183 3184 3185 3186 3187 3188 3189 3190
      more details on the address element.</dd>
      <dt><code>driver</code></dt>
      <dd>
        PCI devices can have an optional <code>driver</code>
        subelement that specifies which backend driver to use for PCI
        device assignment. Use the <code>name</code> attribute to
        select either "vfio" (for the new VFIO device assignment
        backend, which is compatible with UEFI SecureBoot) or "kvm"
3191
        (the legacy device assignment handled directly by the KVM
3192
        kernel module)<span class="since">Since 1.0.5 (QEMU and KVM
3193 3194 3195 3196 3197 3198 3199 3200
        only, requires kernel 3.6 or newer)</span>. When specified,
        device assignment will fail if the requested method of device
        assignment isn't available on the host. When not specified,
        the default is "vfio" on systems where the VFIO driver is
        available and loaded, and "kvm" on older systems, or those
        where the VFIO driver hasn't been
        loaded <span class="since">Since 1.1.3</span> (prior to that
        the default was always "kvm").
3201
      </dd>
O
Osier Yang 已提交
3202 3203 3204 3205
      <dt><code>readonly</code></dt>
      <dd>Indicates that the device is readonly, only supported by SCSI host
        device now. <span class="since">Since 1.0.6 (QEMU and KVM only)</span>
      </dd>
3206 3207 3208 3209 3210
      <dt><code>shareable</code></dt>
      <dd>If present, this indicates the device is expected to be shared
        between domains (assuming the hypervisor and OS support this).
        Only supported by SCSI host device.
        <span class="since">Since 1.0.6</span>
3211 3212 3213 3214 3215
        <p>
          Note: Although <code>shareable</code> was introduced
          <span class="since">in 1.0.6</span>, it did not work as
          as expected until <span class="since">1.2.2</span>.
        </p>
3216
      </dd>
3217 3218
    </dl>

3219

3220
    <h5><a name="elementsHostDevCaps">Block / character devices</a></h5>
3221 3222 3223 3224 3225 3226 3227 3228 3229 3230 3231 3232 3233 3234 3235 3236 3237 3238 3239 3240 3241 3242 3243 3244 3245

    <p>
      Block / character devices from the host can be passed through
      to the guest using the <code>hostdev</code> element. This is
      only possible with container based virtualization.
      <span class="since">since after 1.0.1 for LXC</span>:
    </p>

    <pre>
...
&lt;hostdev mode='capabilities' type='storage'&gt;
  &lt;source&gt;
    &lt;block&gt;/dev/sdf1&lt;/block&gt;
  &lt;/source&gt;
&lt;/hostdev&gt;
...
    </pre>

    <pre>
...
&lt;hostdev mode='capabilities' type='misc'&gt;
  &lt;source&gt;
    &lt;char&gt;/dev/input/event3&lt;/char&gt;
  &lt;/source&gt;
&lt;/hostdev&gt;
3246 3247 3248
...
    </pre>

O
Osier Yang 已提交
3249
    <pre>
3250 3251 3252 3253 3254 3255
...
&lt;hostdev mode='capabilities' type='net'&gt;
  &lt;source&gt;
    &lt;interface&gt;eth0&lt;/interface&gt;
  &lt;/source&gt;
&lt;/hostdev&gt;
3256 3257 3258 3259 3260 3261 3262
...
    </pre>

    <dl>
      <dt><code>hostdev</code></dt>
      <dd>The <code>hostdev</code> element is the main container for describing
        host devices. For block/character device passthrough <code>mode</code> is
3263 3264
        always "capabilities" and <code>type</code> is "storage" for a block
        device, "misc" for a character device and "net" for a host network
3265
        interface.
3266 3267 3268 3269 3270
      </dd>
      <dt><code>source</code></dt>
      <dd>The source element describes the device as seen from the host.
        For block devices, the path to the block device in the host
        OS is provided in the nested "block" element, while for character
3271 3272
        devices the "char" element is used. For network interfaces, the
        name of the interface is provided in the "interface" element.
3273 3274 3275
      </dd>
    </dl>

3276 3277 3278 3279 3280 3281 3282 3283 3284 3285 3286 3287 3288
    <h4><a name="elementsRedir">Redirected devices</a></h4>

    <p>
      USB device redirection through a character device is
      supported <span class="since">since after 0.9.5 (KVM
      only)</span>:
    </p>

<pre>
  ...
  &lt;devices&gt;
    &lt;redirdev bus='usb' type='tcp'&gt;
      &lt;source mode='connect' host='localhost' service='4000'/&gt;
3289
      &lt;boot order='1'/&gt;
3290
    &lt;/redirdev&gt;
3291 3292 3293 3294
    &lt;redirfilter&gt;
      &lt;usbdev class='0x08' vendor='0x1234' product='0xbeef' version='2.00' allow='yes'/&gt;
      &lt;usbdev allow='no'/&gt;
    &lt;/redirfilter&gt;
3295 3296 3297 3298 3299 3300 3301 3302 3303 3304 3305 3306 3307 3308 3309 3310
  &lt;/devices&gt;
  ...</pre>

    <dl>
      <dt><code>redirdev</code></dt>
      <dd>The <code>redirdev</code> element is the main container for
        describing redirected devices. <code>bus</code> must be "usb"
        for a USB device.

        An additional attribute <code>type</code> is required,
        matching one of the
        supported <a href="#elementsConsole">serial device</a> types,
        to describe the host side of the
        tunnel; <code>type='tcp'</code>
        or <code>type='spicevmc'</code> (which uses the usbredir
        channel of a <a href="#elementsGraphics">SPICE graphics
J
Ján Tomko 已提交
3311 3312
        device</a>) are typical. The redirdev element has an optional
        sub-element <code>&lt;address&gt;</code> which can tie the
3313 3314 3315 3316
        device to a particular controller. Further sub-elements,
        such as <code>&lt;source&gt;</code>, may be required according
        to the given type, although a <code>&lt;target&gt;</code> sub-element
        is not required (since the consumer of the character device is
3317 3318 3319 3320 3321 3322 3323 3324 3325 3326
        the hypervisor itself, rather than a device visible in the guest).
      </dd>
      <dt><code>boot</code></dt>

      <dd>Specifies that the device is bootable.
        The <code>order</code> attribute determines the order in which
        devices will be tried during boot sequence. The per-device
        <code>boot</code> elements cannot be used together with general
        boot elements in  <a href="#elementsOSBIOS">BIOS bootloader</a> section.
        (<span class="since">Since 1.0.1</span>)
3327 3328 3329 3330
      </dd>
      <dt><code>redirfilter</code></dt>
      <dd>The<code> redirfilter </code>element is used for creating the
        filter rule to filter out certain devices from redirection.
J
Ján Tomko 已提交
3331 3332
        It uses sub-element <code>&lt;usbdev&gt;</code> to define each filter rule.
        <code>class</code> attribute is the USB Class code, for example,
3333
        0x08 represents mass storage devices. The USB device can be addressed by
J
Ján Tomko 已提交
3334
        vendor / product id using the <code>vendor</code> and <code>product</code> attributes.
3335 3336
        <code>version</code> is the bcdDevice value of USB device, such as 1.00, 1.10 and 2.00.
        These four attributes are optional and <code>-1</code> can be used to allow
J
Ján Tomko 已提交
3337
        any value for them. <code>allow</code> attribute is mandatory,
3338 3339
        'yes' means allow, 'no' for deny.
      </dd>
3340 3341
    </dl>

3342 3343 3344 3345 3346 3347 3348 3349 3350 3351 3352 3353 3354 3355 3356 3357 3358 3359 3360 3361 3362 3363 3364 3365 3366 3367 3368 3369 3370 3371
    <h4><a name="elementsSmartcard">Smartcard devices</a></h4>

    <p>
      A virtual smartcard device can be supplied to the guest via the
      <code>smartcard</code> element. A USB smartcard reader device on
      the host cannot be used on a guest with simple device
      passthrough, since it will then not be available on the host,
      possibly locking the host computer when it is "removed".
      Therefore, some hypervisors provide a specialized virtual device
      that can present a smartcard interface to the guest, with
      several modes for describing how credentials are obtained from
      the host or even a from a channel created to a third-party
      smartcard provider. <span class="since">Since 0.8.8</span>
    </p>

<pre>
  ...
  &lt;devices&gt;
    &lt;smartcard mode='host'/&gt;
    &lt;smartcard mode='host-certificates'&gt;
      &lt;certificate&gt;cert1&lt;/certificate&gt;
      &lt;certificate&gt;cert2&lt;/certificate&gt;
      &lt;certificate&gt;cert3&lt;/certificate&gt;
      &lt;database&gt;/etc/pki/nssdb/&lt;/database&gt;
    &lt;/smartcard&gt;
    &lt;smartcard mode='passthrough' type='tcp'&gt;
      &lt;source mode='bind' host='127.0.0.1' service='2001'/&gt;
      &lt;protocol type='raw'/&gt;
      &lt;address type='ccid' controller='0' slot='0'/&gt;
    &lt;/smartcard&gt;
E
Eric Blake 已提交
3372
    &lt;smartcard mode='passthrough' type='spicevmc'/&gt;
3373 3374 3375 3376 3377 3378 3379 3380 3381 3382 3383 3384 3385 3386 3387 3388 3389 3390 3391 3392 3393 3394 3395 3396 3397 3398 3399 3400 3401 3402 3403 3404 3405 3406 3407 3408 3409 3410 3411 3412 3413 3414
  &lt;/devices&gt;
  ...
</pre>

    <p>
      The <code>&lt;smartcard&gt;</code> element has a mandatory
      attribute <code>mode</code>.  The following modes are supported;
      in each mode, the guest sees a device on its USB bus that
      behaves like a physical USB CCID (Chip/Smart Card Interface
      Device) card.
    </p>

    <dl>
      <dt><code>mode='host'</code></dt>
      <dd>The simplest operation, where the hypervisor relays all
      requests from the guest into direct access to the host's
      smartcard via NSS.  No other attributes or sub-elements are
      required.  See below about the use of an
      optional <code>&lt;address&gt;</code> sub-element.</dd>

      <dt><code>mode='host-certificates'</code></dt>
      <dd>Rather than requiring a smartcard to be plugged into the
      host, it is possible to provide three NSS certificate names
      residing in a database on the host.  These certificates can be
      generated via the command <code>certutil -d /etc/pki/nssdb -x -t
      CT,CT,CT -S -s CN=cert1 -n cert1</code>, and the resulting three
      certificate names must be supplied as the content of each of
      three <code>&lt;certificate&gt;</code> sub-elements.  An
      additional sub-element <code>&lt;database&gt;</code> can specify
      the absolute path to an alternate directory (matching
      the <code>-d</code> option of the <code>certutil</code> command
      when creating the certificates); if not present, it defaults to
      /etc/pki/nssdb.</dd>

      <dt><code>mode='passthrough'</code></dt>
      <dd>Rather than having the hypervisor directly communicate with
      the host, it is possible to tunnel all requests through a
      secondary character device to a third-party provider (which may
      in turn be talking to a smartcard or using three certificate
      files).  In this mode of operation, an additional
      attribute <code>type</code> is required, matching one of the
      supported <a href="#elementsConsole">serial device</a> types, to
E
Eric Blake 已提交
3415 3416 3417 3418 3419
      describe the host side of the tunnel; <code>type='tcp'</code>
      or <code>type='spicevmc'</code> (which uses the smartcard
      channel of a <a href="#elementsGraphics">SPICE graphics
      device</a>) are typical.  Further sub-elements, such
      as <code>&lt;source&gt;</code>, may be required according to the
3420 3421 3422 3423 3424 3425 3426 3427 3428
      given type, although a <code>&lt;target&gt;</code> sub-element
      is not required (since the consumer of the character device is
      the hypervisor itself, rather than a device visible in the
      guest).</dd>
    </dl>

    <p>
      Each mode supports an optional
      sub-element <code>&lt;address&gt;</code>, which fine-tunes the
3429 3430 3431
      correlation between the smartcard and a ccid bus
      controller, <a href="#elementsAddress">documented above</a>.
      For now, qemu only supports at most one
3432 3433 3434
      smartcard, with an address of bus=0 slot=0.
    </p>

D
Daniel P. Berrange 已提交
3435 3436
    <h4><a name="elementsNICS">Network interfaces</a></h4>

3437 3438 3439
<pre>
  ...
  &lt;devices&gt;
3440 3441 3442
    &lt;interface type='direct' trustGuestRxFilters='yes'&gt;
      &lt;source dev='eth0'/&gt;
      &lt;mac address='52:54:00:5d:c7:9e'/&gt;
3443
      &lt;boot order='1'/&gt;
3444
      &lt;rom bar='off'/&gt;
3445 3446 3447
    &lt;/interface&gt;
  &lt;/devices&gt;
  ...</pre>
D
Daniel P. Berrange 已提交
3448

E
Eric Blake 已提交
3449 3450 3451
    <p>
      There are several possibilities for specifying a network
      interface visible to the guest.  Each subsection below provides
3452 3453 3454 3455 3456 3457 3458 3459 3460 3461 3462 3463
      more details about common setup options.
    </p>
    <p>
      <span class="since">Since 1.2.10</span>),
      the <code>interface</code> element
      property <code>trustGuestRxFilters</code> provides the
      capability for the host to detect and trust reports from the
      guest regarding changes to the interface mac address and receive
      filters by setting the attribute to <code>yes</code>. The default
      setting for the attribute is <code>no</code> for security
      reasons and support depends on the guest network device model as
      well as the type of connection on the host - currently it is
C
Chen Fan 已提交
3464
      only supported for the virtio device model and for macvtap
3465 3466 3467 3468
      connections on the host.
    </p>
    <p>
      Each <code>&lt;interface&gt;</code> element has an
E
Eric Blake 已提交
3469 3470
      optional <code>&lt;address&gt;</code> sub-element that can tie
      the interface to a particular pci slot, with
3471 3472
      attribute <code>type='pci'</code>
      as <a href="#elementsAddress">documented above</a>.
E
Eric Blake 已提交
3473 3474
    </p>

D
Daniel P. Berrange 已提交
3475 3476 3477 3478 3479
    <h5><a name="elementsNICSVirtual">Virtual network</a></h5>

    <p>
      <strong><em>
      This is the recommended config for general guest connectivity on
3480 3481 3482 3483
      hosts with dynamic / wireless networking configs (or multi-host
      environments where the host hardware details are described
      separately in a <code>&lt;network&gt;</code>
      definition <span class="since">Since 0.9.4</span>).
D
Daniel P. Berrange 已提交
3484 3485 3486 3487
      </em></strong>
    </p>

    <p>
3488 3489 3490 3491 3492 3493 3494 3495 3496 3497 3498 3499 3500 3501 3502 3503 3504 3505 3506 3507 3508 3509 3510 3511 3512 3513 3514

      Provides a connection whose details are described by the named
      network definition. Depending on the virtual network's "forward
      mode" configuration, the network may be totally isolated
      (no <code>&lt;forward&gt;</code> element given), NAT'ing to an
      explicit network device or to the default route
      (<code>&lt;forward mode='nat'&gt;</code>), routed with no NAT
      (<code>&lt;forward mode='route'/&gt;</code>), or connected
      directly to one of the host's network interfaces (via macvtap)
      or bridge devices ((<code>&lt;forward
      mode='bridge|private|vepa|passthrough'/&gt;</code> <span class="since">Since
      0.9.4</span>)
    </p>
    <p>
      For networks with a forward mode of bridge, private, vepa, and
      passthrough, it is assumed that the host has any necessary DNS
      and DHCP services already setup outside the scope of libvirt. In
      the case of isolated, nat, and routed networks, DHCP and DNS are
      provided on the virtual network by libvirt, and the IP range can
      be determined by examining the virtual network config with
      '<code>virsh net-dumpxml [networkname]</code>'. There is one
      virtual network called 'default' setup out of the box which does
      NAT'ing to the default route and has an IP range
      of <code>192.168.122.0/255.255.255.0</code>. Each guest will
      have an associated tun device created with a name of vnetN,
      which can also be overridden with the &lt;target&gt; element
      (see
3515
      <a href="#elementsNICSTargetOverride">overriding the target element</a>).
D
Daniel P. Berrange 已提交
3516
    </p>
3517 3518 3519 3520 3521 3522
    <p>
      When the source of an interface is a network,
      a <code>portgroup</code> can be specified along with the name of
      the network; one network may have multiple portgroups defined,
      with each portgroup containing slightly different configuration
      information for different classes of network
3523 3524 3525 3526 3527 3528 3529 3530 3531 3532 3533 3534 3535 3536 3537 3538 3539 3540 3541
      connections. <span class="since">Since 0.9.4</span>.
    </p>
    <p>
      Also, similar to <code>direct</code> network connections
      (described below), a connection of type <code>network</code> may
      specify a <code>virtualport</code> element, with configuration
      data to be forwarded to a vepa (802.1Qbg) or 802.1Qbh compliant
      switch (<span class="since">Since 0.8.2</span>), or to an
      Open vSwitch virtual switch (<span class="since">Since
      0.9.11</span>).
    </p>
    <p>
      Since the actual type of switch may vary depending on the
      configuration in the <code>&lt;network&gt;</code> on the host,
      it is acceptable to omit the virtualport <code>type</code>
      attribute, and specify attributes from multiple different
      virtualport types (and also to leave out certain attributes); at
      domain startup time, a complete <code>&lt;virtualport&gt;</code>
      element will be constructed by merging together the type and
G
Guannan Ren 已提交
3542 3543 3544 3545 3546
      attributes defined in the network and the portgroup referenced
      by the interface. The newly-constructed virtualport is a combination
      of them. The attributes from lower virtualport can't make change
      on the ones defined in higher virtualport.
      Interface takes the highest priority, portgroup is lowest priority.
3547 3548 3549
      (<span class="since">Since 0.10.0</span>). For example, in order
      to work properly with both an 802.1Qbh switch and an Open vSwitch
      switch, you may choose to specify no type, but both
G
Guannan Ren 已提交
3550
      an <code>profileid</code> (in case the switch is 802.1Qbh) and
3551 3552 3553 3554 3555 3556 3557 3558 3559
      an <code>interfaceid</code> (in case the switch is Open vSwitch)
      (you may also omit the other attributes, such as managerid,
      typeid, or profileid, to be filled in from the
      network's <code>&lt;virtualport&gt;</code>). If you want to
      limit a guest to connecting only to certain types of switches,
      you can specify the virtualport type, but still omit some/all of
      the parameters - in this case if the host's network has a
      different type of virtualport, connection of the interface will
      fail.
3560
    </p>
D
Daniel P. Berrange 已提交
3561

3562 3563 3564 3565 3566 3567 3568 3569
<pre>
  ...
  &lt;devices&gt;
    &lt;interface type='network'&gt;
      &lt;source network='default'/&gt;
    &lt;/interface&gt;
    ...
    &lt;interface type='network'&gt;
3570
      &lt;source network='default' portgroup='engineering'/&gt;
3571
      &lt;target dev='vnet7'/&gt;
3572
      &lt;mac address="00:11:22:33:44:55"/&gt;
3573 3574
      &lt;virtualport&gt;
        &lt;parameters instanceid='09b11c53-8b5c-4eeb-8f00-d84eaa0aaa4f'/&gt;
3575 3576
      &lt;/virtualport&gt;

3577 3578 3579
    &lt;/interface&gt;
  &lt;/devices&gt;
  ...</pre>
D
Daniel P. Berrange 已提交
3580

D
Dan Kenigsberg 已提交
3581
    <h5><a name="elementsNICSBridge">Bridge to LAN</a></h5>
D
Daniel P. Berrange 已提交
3582 3583 3584 3585

    <p>
      <strong><em>
      This is the recommended config for general guest connectivity on
3586
      hosts with static wired networking configs.
D
Daniel P. Berrange 已提交
3587 3588 3589 3590
      </em></strong>
    </p>

    <p>
E
Eric Blake 已提交
3591
      Provides a bridge from the VM directly to the LAN. This assumes
D
Daniel P. Berrange 已提交
3592 3593 3594
      there is a bridge device on the host which has one or more of the hosts
      physical NICs enslaved. The guest VM will have an associated tun device
      created with a name of vnetN, which can also be overridden with the
3595 3596 3597 3598 3599
      &lt;target&gt; element (see
      <a href="#elementsNICSTargetOverride">overriding the target element</a>).
      The tun device will be enslaved to the bridge. The IP range / network
      configuration is whatever is used on the LAN. This provides the guest VM
      full incoming &amp; outgoing net access just like a physical machine.
D
Daniel P. Berrange 已提交
3600
    </p>
3601 3602 3603 3604 3605 3606 3607 3608 3609 3610
    <p>
      On Linux systems, the bridge device is normally a standard Linux
      host bridge. On hosts that support Open vSwitch, it is also
      possible to connect to an open vSwitch bridge device by adding
      a <code>&lt;virtualport type='openvswitch'/&gt;</code> to the
      interface definition.  (<span class="since">Since
      0.9.11</span>). The Open vSwitch type virtualport accepts two
      parameters in its <code>&lt;parameters&gt;</code> element -
      an <code>interfaceid</code> which is a standard uuid used to
      uniquely identify this particular interface to Open vSwitch (if
C
Chen Hanxiao 已提交
3611
      you do not specify one, a random interfaceid will be generated
3612 3613 3614 3615
      for you when you first define the interface), and an
      optional <code>profileid</code> which is sent to Open vSwitch as
      the interfaces "port-profile".
    </p>
3616 3617 3618
<pre>
  ...
  &lt;devices&gt;
3619
    ...
3620 3621 3622 3623
    &lt;interface type='bridge'&gt;
      &lt;source bridge='br0'/&gt;
    &lt;/interface&gt;
    &lt;interface type='bridge'&gt;
3624
      &lt;source bridge='br1'/&gt;
3625
      &lt;target dev='vnet7'/&gt;
3626
      &lt;mac address="00:11:22:33:44:55"/&gt;
3627
    &lt;/interface&gt;
3628 3629
    &lt;interface type='bridge'&gt;
      &lt;source bridge='ovsbr'/&gt;
E
Eric Blake 已提交
3630
      &lt;virtualport type='openvswitch'&gt;
3631 3632 3633 3634
        &lt;parameters profileid='menial' interfaceid='09b11c53-8b5c-4eeb-8f00-d84eaa0aaa4f'/&gt;
      &lt;/virtualport&gt;
    &lt;/interface&gt;
    ...
3635 3636
  &lt;/devices&gt;
  ...</pre>
D
Daniel P. Berrange 已提交
3637 3638 3639 3640 3641 3642 3643 3644 3645 3646 3647 3648

    <h5><a name="elementsNICSSlirp">Userspace SLIRP stack</a></h5>

    <p>
      Provides a virtual LAN with NAT to the outside world. The virtual
      network has DHCP &amp; DNS services and will give the guest VM addresses
      starting from <code>10.0.2.15</code>. The default router will be
      <code>10.0.2.2</code> and the DNS server will be <code>10.0.2.3</code>.
      This networking is the only option for unprivileged users who need their
      VMs to have outgoing access.
    </p>

3649 3650 3651 3652 3653 3654
<pre>
  ...
  &lt;devices&gt;
    &lt;interface type='user'/&gt;
    ...
    &lt;interface type='user'&gt;
3655
      &lt;mac address="00:11:22:33:44:55"/&gt;
3656 3657 3658
    &lt;/interface&gt;
  &lt;/devices&gt;
  ...</pre>
D
Daniel P. Berrange 已提交
3659 3660 3661 3662 3663 3664 3665 3666 3667 3668 3669 3670 3671 3672


    <h5><a name="elementsNICSEthernet">Generic ethernet connection</a></h5>

    <p>
      Provides a means for the administrator to execute an arbitrary script
      to connect the guest's network to the LAN. The guest will have a tun
      device created with a name of vnetN, which can also be overridden with the
      &lt;target&gt; element. After creating the tun device a shell script will
      be run which is expected to do whatever host network integration is
      required. By default this script is called /etc/qemu-ifup but can be
      overridden.
    </p>

3673 3674 3675 3676 3677 3678 3679 3680 3681 3682 3683
<pre>
  ...
  &lt;devices&gt;
    &lt;interface type='ethernet'/&gt;
    ...
    &lt;interface type='ethernet'&gt;
      &lt;target dev='vnet7'/&gt;
      &lt;script path='/etc/qemu-ifup-mynet'/&gt;
    &lt;/interface&gt;
  &lt;/devices&gt;
  ...</pre>
D
Daniel P. Berrange 已提交
3684

3685 3686 3687 3688
    <h5><a name="elementsNICSDirect">Direct attachment to physical interface</a></h5>

    <p>
      Provides direct attachment of the virtual machine's NIC to the given
3689
      physical interface of the host.
E
Eric Blake 已提交
3690
      <span class="since">Since 0.7.7 (QEMU and KVM only)</span><br/>
3691 3692 3693
      This setup requires the Linux macvtap
      driver to be available. <span class="since">(Since Linux 2.6.34.)</span>
      One of the modes 'vepa'
3694
      ( <a href="http://www.ieee802.org/1/files/public/docs2009/new-evb-congdon-vepa-modular-0709-v01.pdf">
3695
      'Virtual Ethernet Port Aggregator'</a>), 'bridge' or 'private'
3696
      can be chosen for the operation mode of the macvtap device, 'vepa'
3697 3698
      being the default mode. The individual modes cause the delivery of
      packets to behave as follows:
3699
    </p>
3700 3701 3702 3703 3704 3705 3706 3707 3708 3709 3710 3711
    <p>
      If the model type is set to <code>virtio</code> and
      interface's <code>trustGuestRxFilters</code> attribute is set
      to <code>yes</code>, changes made to the interface mac address,
      unicast/multicast receive filters, and vlan settings in the
      guest will be monitored and propagated to the associated macvtap
      device on the host (<span class="since">Since
      1.2.10</span>). If <code>trustGuestRxFilters</code> is not set,
      or is not supported for the device model in use, an attempted
      change to the mac address originating from the guest side will
      result in a non-working network connection.
    </p>
3712

3713 3714 3715 3716 3717 3718 3719 3720 3721 3722 3723
    <dl>
      <dt><code>vepa</code></dt>
      <dd>All VMs' packets are sent to the external bridge. Packets
      whose destination is a VM on the same host as where the
      packet originates from are sent back to the host by the VEPA
      capable bridge (today's bridges are typically not VEPA capable).</dd>
      <dt><code>bridge</code></dt>
      <dd>Packets whose destination is on the same host as where they
      originate from are directly delivered to the target macvtap device.
      Both origin and destination devices need to be in bridge mode
      for direct delivery. If either one of them is in <code>vepa</code> mode,
E
Eric Blake 已提交
3724
      a VEPA capable bridge is required.</dd>
3725 3726 3727 3728 3729 3730
      <dt><code>private</code></dt>
      <dd>All packets are sent to the external bridge and will only be
      delivered to a target VM on the same host if they are sent through an
      external router or gateway and that device sends them back to the
      host. This procedure is followed if either the source or destination
      device is in <code>private</code> mode.</dd>
3731 3732 3733 3734 3735 3736 3737
      <dt><code>passthrough</code></dt>
      <dd>This feature attaches a virtual function of a SRIOV capable
      NIC directly to a VM without losing the migration capability.
      All packets are sent to the VF/IF of the configured network device.
      Depending on the capabilities of the device additional prerequisites or
      limitations may apply; for example, on Linux this requires
      kernel 2.6.38 or newer. <span class="since">Since 0.9.2</span></dd>
3738 3739
    </dl>

3740 3741 3742 3743
<pre>
  ...
  &lt;devices&gt;
    ...
3744
    &lt;interface type='direct' trustGuestRxFilters='no'&gt;
3745 3746 3747 3748 3749
      &lt;source dev='eth0' mode='vepa'/&gt;
    &lt;/interface&gt;
  &lt;/devices&gt;
  ...</pre>

3750 3751 3752 3753
    <p>
      The network access of direct attached virtual machines can be
      managed by the hardware switch to which the physical interface
      of the host machine is connected to.
E
Eric Blake 已提交
3754
    </p>
3755 3756 3757 3758 3759 3760 3761
    <p>
      The interface can have additional parameters as shown below,
      if the switch is conforming to the IEEE 802.1Qbg standard.
      The parameters of the virtualport element are documented in more detail
      in the IEEE 802.1Qbg standard. The values are network specific and
      should be provided by the network administrator. In 802.1Qbg terms,
      the Virtual Station Interface (VSI) represents the virtual interface
3762
      of a virtual machine. <span class="since">Since 0.8.2</span>
3763
    </p>
3764 3765 3766 3767
    <p>
      Please note that IEEE 802.1Qbg requires a non-zero value for the
      VLAN ID.
    </p>
3768 3769 3770 3771 3772 3773 3774 3775 3776 3777 3778 3779 3780 3781 3782 3783 3784 3785 3786 3787 3788 3789 3790 3791 3792
    <dl>
      <dt><code>managerid</code></dt>
      <dd>The VSI Manager ID identifies the database containing the VSI type
        and instance definitions. This is an integer value and the
        value 0 is reserved.</dd>
      <dt><code>typeid</code></dt>
      <dd>The VSI Type ID identifies a VSI type characterizing the network
        access. VSI types are typically managed by network administrator.
        This is an integer value.
      </dd>
      <dt><code>typeidversion</code></dt>
      <dd>The VSI Type Version allows multiple versions of a VSI Type.
        This is an integer value.
      </dd>
      <dt><code>instanceid</code></dt>
      <dd>The VSI Instance ID Identifier is generated when a VSI instance
        (i.e. a virtual interface of a virtual machine) is created.
        This is a globally unique identifier.
      </dd>
    </dl>
<pre>
  ...
  &lt;devices&gt;
    ...
    &lt;interface type='direct'&gt;
3793
      &lt;source dev='eth0.2' mode='vepa'/&gt;
3794 3795 3796 3797 3798 3799
      &lt;virtualport type="802.1Qbg"&gt;
        &lt;parameters managerid="11" typeid="1193047" typeidversion="2" instanceid="09b11c53-8b5c-4eeb-8f00-d84eaa0aaa4f"/&gt;
      &lt;/virtualport&gt;
    &lt;/interface&gt;
  &lt;/devices&gt;
  ...</pre>
3800

3801 3802 3803 3804 3805 3806 3807 3808 3809
    <p>
      The interface can have additional parameters as shown below
      if the switch is conforming to the IEEE 802.1Qbh standard.
      The values are network specific and should be provided by the
      network administrator. <span class="since">Since 0.8.2</span>
    </p>
    <dl>
      <dt><code>profileid</code></dt>
      <dd>The profile ID contains the name of the port profile that is to
E
Eric Blake 已提交
3810
        be applied to this interface.  This name is resolved by the port
3811 3812 3813 3814 3815 3816 3817 3818 3819 3820 3821 3822 3823 3824 3825 3826 3827 3828
        profile database into the network parameters from the port profile,
        and those network parameters will be applied to this interface.
      </dd>
    </dl>
  <pre>
  ...
  &lt;devices&gt;
    ...
    &lt;interface type='direct'&gt;
      &lt;source dev='eth0' mode='private'/&gt;
      &lt;virtualport type='802.1Qbh'&gt;
        &lt;parameters profileid='finance'/&gt;
      &lt;/virtualport&gt;
    &lt;/interface&gt;
  &lt;/devices&gt;
  ...
  </pre>

3829 3830 3831 3832 3833 3834 3835 3836

    <h5><a name="elementsNICSHostdev">PCI Passthrough</a></h5>

    <p>
      A PCI network device (specified by the &lt;source&gt; element)
      is directly assigned to the guest using generic device
      passthrough, after first optionally setting the device's MAC
      address to the configured value, and associating the device with
3837
      an 802.1Qbh capable switch using an optionally specified
3838
      &lt;virtualport&gt; element (see the examples of virtualport
3839 3840 3841 3842 3843 3844 3845 3846 3847
      given above for type='direct' network devices). Note that - due
      to limitations in standard single-port PCI ethernet card driver
      design - only SR-IOV (Single Root I/O Virtualization) virtual
      function (VF) devices can be assigned in this manner; to assign
      a standard single-port PCI or PCIe ethernet card to a guest, use
      the traditional &lt;hostdev&gt; device definition and
      <span class="since">Since 0.9.11</span>
    </p>

3848 3849 3850 3851 3852 3853 3854 3855 3856 3857 3858 3859
    <p>
      To use VFIO device assignment rather than traditional/legacy KVM
      device assignment (VFIO is a new method of device assignment
      that is compatible with UEFI Secure Boot), a type='hostdev'
      interface can have an optional <code>driver</code> sub-element
      with a <code>name</code> attribute set to "vfio". To use legacy
      KVM device assignment you can set <code>name</code> to "kvm" (or
      simply omit the <code>&lt;driver&gt;</code> element, since "kvm"
      is currently the default).
      <span class="since">Since 1.0.5 (QEMU and KVM only, requires kernel 3.6 or newer)</span>
    </p>

3860 3861 3862 3863 3864 3865 3866 3867 3868 3869 3870 3871 3872 3873
    <p>
      Note that this "intelligent passthrough" of network devices is
      very similar to the functionality of a standard &lt;hostdev&gt;
      device, the difference being that this method allows specifying
      a MAC address and &lt;virtualport&gt; for the passed-through
      device. If these capabilities are not required, if you have a
      standard single-port PCI, PCIe, or USB network card that doesn't
      support SR-IOV (and hence would anyway lose the configured MAC
      address during reset after being assigned to the guest domain),
      or if you are using a version of libvirt older than 0.9.11, you
      should use standard &lt;hostdev&gt; to assign the device to the
      guest instead of &lt;interface type='hostdev'/&gt;.
    </p>

3874 3875 3876 3877 3878 3879
    <p>
      Similar to the functionality of a standard &lt;hostdev&gt; device,
      when <code>managed</code> is "yes", it is detached from the host
      before being passed on to the guest, and reattached to the host
      after the guest exits. If <code>managed</code> is omitted or "no",
      the user is responsible to call <code>virNodeDeviceDettach</code>
J
John Ferlan 已提交
3880
      (or <code>virsh nodedev-detach</code>) before starting the guest
3881 3882 3883 3884 3885
      or hot-plugging the device, and <code>virNodeDeviceReAttach</code>
      (or <code>virsh nodedev-reattach</code>) after hot-unplug or
      stopping the guest.
    </p>

3886 3887 3888
<pre>
  ...
  &lt;devices&gt;
3889
    &lt;interface type='hostdev' managed='yes'&gt;
3890
      &lt;driver name='vfio'/&gt;
3891 3892 3893
      &lt;source&gt;
        &lt;address type='pci' domain='0x0000' bus='0x00' slot='0x07' function='0x0'/&gt;
      &lt;/source&gt;
3894
      &lt;mac address='52:54:00:6d:90:02'/&gt;
3895 3896 3897 3898 3899 3900 3901 3902
      &lt;virtualport type='802.1Qbh'&gt;
        &lt;parameters profileid='finance'/&gt;
      &lt;/virtualport&gt;
    &lt;/interface&gt;
  &lt;/devices&gt;
  ...</pre>


D
Daniel P. Berrange 已提交
3903 3904 3905 3906 3907 3908 3909 3910 3911 3912 3913 3914 3915 3916
    <h5><a name="elementsNICSMulticast">Multicast tunnel</a></h5>

    <p>
      A multicast group is setup to represent a virtual network. Any VMs
      whose network devices are in the same multicast group can talk to each
      other even across hosts. This mode is also available to unprivileged
      users. There is no default DNS or DHCP support and no outgoing network
      access. To provide outgoing network access, one of the VMs should have a
      2nd NIC which is connected to one of the first 4 network types and do the
      appropriate routing. The multicast protocol is compatible with that used
      by user mode linux guests too. The source address used must be from the
      multicast address block.
    </p>

3917 3918 3919 3920
<pre>
  ...
  &lt;devices&gt;
    &lt;interface type='mcast'&gt;
3921
      &lt;mac address='52:54:00:6d:90:01'/&gt;
3922 3923 3924 3925
      &lt;source address='230.0.0.1' port='5558'/&gt;
    &lt;/interface&gt;
  &lt;/devices&gt;
  ...</pre>
D
Daniel P. Berrange 已提交
3926 3927 3928 3929 3930 3931 3932 3933 3934 3935 3936 3937

    <h5><a name="elementsNICSTCP">TCP tunnel</a></h5>

    <p>
      A TCP client/server architecture provides a virtual network. One VM
      provides the server end of the network, all other VMS are configured as
      clients. All network traffic is routed between the VMs via the server.
      This mode is also available to unprivileged users. There is no default
      DNS or DHCP support and no outgoing network access. To provide outgoing
      network access, one of the VMs should have a 2nd NIC which is connected
      to one of the first 4 network types and do the appropriate routing.</p>

3938 3939 3940 3941
<pre>
  ...
  &lt;devices&gt;
    &lt;interface type='server'&gt;
J
Jianwei Hu 已提交
3942
      &lt;mac address='52:54:00:22:c9:42'/&gt;
D
Daniel P. Berrange 已提交
3943
      &lt;source address='192.168.0.1' port='5558'/&gt;
3944 3945 3946
    &lt;/interface&gt;
    ...
    &lt;interface type='client'&gt;
J
Jianwei Hu 已提交
3947
      &lt;mac address='52:54:00:8b:c9:51'/&gt;
3948
      &lt;source address='192.168.0.1' port='5558'/&gt;
3949 3950 3951
    &lt;/interface&gt;
  &lt;/devices&gt;
  ...</pre>
D
Daniel P. Berrange 已提交
3952

3953 3954
    <h5><a name="elementsNICSModel">Setting the NIC model</a></h5>

3955 3956 3957 3958 3959 3960 3961 3962 3963 3964
<pre>
  ...
  &lt;devices&gt;
    &lt;interface type='network'&gt;
      &lt;source network='default'/&gt;
      &lt;target dev='vnet1'/&gt;
      <b>&lt;model type='ne2k_pci'/&gt;</b>
    &lt;/interface&gt;
  &lt;/devices&gt;
  ...</pre>
3965 3966 3967 3968 3969 3970 3971 3972 3973 3974 3975 3976 3977 3978 3979 3980 3981 3982 3983 3984 3985 3986

    <p>
      For hypervisors which support this, you can set the model of
      emulated network interface card.
    </p>

    <p>
      The values for <code>type</code> aren't defined specifically by
      libvirt, but by what the underlying hypervisor supports (if
      any).  For QEMU and KVM you can get a list of supported models
      with these commands:
    </p>

<pre>
qemu -net nic,model=? /dev/null
qemu-kvm -net nic,model=? /dev/null
</pre>

    <p>
      Typical values for QEMU and KVM include:
      ne2k_isa i82551 i82557b i82559er ne2k_pci pcnet rtl8139 e1000 virtio
    </p>
D
Daniel P. Berrange 已提交
3987

3988 3989 3990 3991 3992 3993 3994 3995 3996
    <h5><a name="elementsDriverBackendOptions">Setting NIC driver-specific options</a></h5>

<pre>
  ...
  &lt;devices&gt;
    &lt;interface type='network'&gt;
      &lt;source network='default'/&gt;
      &lt;target dev='vnet1'/&gt;
      &lt;model type='virtio'/&gt;
3997 3998 3999 4000 4001
      <b>&lt;driver name='vhost' txmode='iothread' ioeventfd='on' event_idx='off' queues='5'&gt;
        &lt;host csum='off' gso='off' tso4='off' tso6='off' ecn='off' ufo='off'/&gt;
        &lt;guest csum='off' tso4='off' tso6='off' ecn='off' ufo='off'/&gt;
      &lt;/driver&gt;
      </b>
4002 4003 4004 4005 4006 4007 4008 4009 4010 4011 4012 4013
    &lt;/interface&gt;
  &lt;/devices&gt;
  ...</pre>

    <p>
      Some NICs may have tunable driver-specific options. These are
      set as attributes of the <code>driver</code> sub-element of the
      interface definition. Currently the following attributes are
      available for the <code>"virtio"</code> NIC driver:
    </p>

    <dl>
4014 4015 4016 4017 4018 4019 4020 4021 4022 4023 4024 4025
      <dt><code>name</code></dt>
      <dd>
        The optional <code>name</code> attribute forces which type of
        backend driver to use. The value can be either 'qemu' (a
        user-space backend) or 'vhost' (a kernel backend, which
        requires the vhost module to be provided by the kernel); an
        attempt to require the vhost driver without kernel support
        will be rejected.  If this attribute is not present, then the
        domain defaults to 'vhost' if present, but silently falls back
        to 'qemu' without error.
        <span class="since">Since 0.8.8 (QEMU and KVM only)</span>
      </dd>
4026 4027 4028 4029 4030 4031 4032 4033 4034 4035 4036 4037 4038
      <dd>
        For interfaces of type='hostdev' (PCI passthrough devices)
        the <code>name</code> attribute can optionally be set to
        "vfio" or "kvm". "vfio" tells libvirt to use VFIO device
        assignment rather than traditional KVM device assignment (VFIO
        is a new method of device assignment that is compatible with
        UEFI Secure Boot), and "kvm" tells libvirt to use the legacy
        device assignment performed directly by the kvm kernel module
        (the default is currently "kvm", but is subject to change).
        <span class="since">Since 1.0.5 (QEMU and KVM only, requires
        kernel 3.6 or newer)</span>
      </dd>

4039 4040 4041 4042 4043
      <dt><code>txmode</code></dt>
      <dd>
        The <code>txmode</code> attribute specifies how to handle
        transmission of packets when the transmit buffer is full. The
        value can be either 'iothread' or 'timer'.
E
Eric Blake 已提交
4044
        <span class="since">Since 0.8.8 (QEMU and KVM only)</span><br/><br/>
4045 4046 4047 4048

        If set to 'iothread', packet tx is all done in an iothread in
        the bottom half of the driver (this option translates into
        adding "tx=bh" to the qemu commandline -device virtio-net-pci
E
Eric Blake 已提交
4049
        option).<br/><br/>
4050 4051 4052 4053

        If set to 'timer', tx work is done in qemu, and if there is
        more tx data than can be sent at the present time, a timer is
        set before qemu moves on to do other things; when the timer
E
Eric Blake 已提交
4054
        fires, another attempt is made to send more data.<br/><br/>
4055 4056 4057 4058 4059

        The resulting difference, according to the qemu developer who
        added the option is: "bh makes tx more asynchronous and reduces
        latency, but potentially causes more processor bandwidth
        contention since the cpu doing the tx isn't necessarily the
E
Eric Blake 已提交
4060
        cpu where the guest generated the packets."<br/><br/>
4061

4062 4063 4064 4065 4066 4067 4068 4069 4070 4071 4072 4073 4074 4075 4076 4077
        <b>In general you should leave this option alone, unless you
        are very certain you know what you are doing.</b>
      </dd>
      <dt><code>ioeventfd</code></dt>
      <dd>
        This optional attribute allows users to set
        <a href='https://patchwork.kernel.org/patch/43390/'>
        domain I/O asynchronous handling</a> for interface device.
        The default is left to the discretion of the hypervisor.
        Accepted values are "on" and "off". Enabling this allows
        qemu to execute VM while a separate thread handles I/O.
        Typically guests experiencing high system CPU utilization
        during I/O will benefit from this. On the other hand,
        on overloaded host it could increase guest I/O latency.
        <span class="since">Since 0.9.3 (QEMU and KVM only)</span><br/><br/>

4078
        <b>In general you should leave this option alone, unless you
4079 4080 4081 4082 4083 4084
        are very certain you know what you are doing.</b>
      </dd>
      <dt><code>event_idx</code></dt>
      <dd>
        The <code>event_idx</code> attribute controls some aspects of
        device event processing. The value can be either 'on' or 'off'
4085
        - if it is on, it will reduce the number of interrupts and
4086 4087 4088 4089 4090 4091 4092
        exits for the guest. The default is determined by QEMU;
        usually if the feature is supported, default is on. In case
        there is a situation where this behavior is suboptimal, this
        attribute provides a way to force the feature off.
        <span class="since">Since 0.9.5 (QEMU and KVM only)</span><br/><br/>

        <b>In general you should leave this option alone, unless you
4093 4094
        are very certain you know what you are doing.</b>
      </dd>
4095 4096 4097 4098 4099 4100 4101 4102 4103 4104
      <dt><code>queues</code></dt>
      <dd>
        The optional <code>queues</code> attribute controls the number of
        queues to be used for the<a href="http://www.linux-kvm.org/page/Multiqueue">
        Multiqueue virtio-net</a> feature. If the interface has <code>&lt;model
        type='virtio'/&gt;</code>, multiple packet processing queues can be
        created; each queue will potentially be handled by a different
        processor, resulting in much higher throughput.
        <span class="since">Since 1.0.6 (QEMU and KVM only)</span>
      </dd>
4105 4106 4107 4108 4109 4110 4111 4112 4113 4114 4115 4116 4117 4118 4119 4120 4121 4122
      <dt><code>host</code> offloading options</dt>
      <dd>
        The <code>csum</code>, <code>gso</code>, <code>tso4</code>,
        <code>tso6</code>, <code>ecn</code> and <code>ufo</code>
        attributes with possible values <code>on</code>
        and <code>off</code> can be used to turn off host offloading options.
        By default, the supported offloads are enabled by QEMU.
        <span class="since">Since 1.2.9 (QEMU only)</span>
      </dd>
      <dt><code>guest</code> offloading options</dt>
      <dd>
        The <code>csum</code>, <code>tso4</code>,
        <code>tso6</code>, <code>ecn</code> and <code>ufo</code>
        attributes with possible values <code>on</code>
        and <code>off</code> can be used to turn off guest offloading options.
        By default, the supported offloads are enabled by QEMU.
        <span class="since">Since 1.2.9 (QEMU only)</span>
      </dd>
4123 4124
    </dl>

4125 4126 4127 4128 4129 4130 4131 4132 4133
    <h5><a name="elementsBackendOptions">Setting network backend-specific options</a></h5>

<pre>
  ...
  &lt;devices&gt;
    &lt;interface type='network'&gt;
      &lt;source network='default'/&gt;
      &lt;target dev='vnet1'/&gt;
      &lt;model type='virtio'/&gt;
4134
      <b>&lt;backend tap='/dev/net/tun' vhost='/dev/vhost-net'/&gt;</b>
4135 4136 4137 4138 4139 4140 4141 4142 4143 4144
      &lt;driver name='vhost' txmode='iothread' ioeventfd='on' event_idx='off' queues='5'/&gt;
    &lt;/interface&gt;
  &lt;/devices&gt;
  ...</pre>

    <p>
      For tuning the backend of the network, the <code>backend</code> element
      can be used. Supported attributes are <code>tap</code> and <code>vhost</code>,
      allowing to override the default devices for creating tap and vhost devices.
    </p>
4145 4146
    <h5><a name="elementsNICSTargetOverride">Overriding the target element</a></h5>

4147 4148 4149 4150 4151 4152 4153 4154 4155
<pre>
  ...
  &lt;devices&gt;
    &lt;interface type='network'&gt;
      &lt;source network='default'/&gt;
      <b>&lt;target dev='vnet1'/&gt;</b>
    &lt;/interface&gt;
  &lt;/devices&gt;
  ...</pre>
4156 4157

    <p>
E
Eric Blake 已提交
4158 4159
      If no target is specified, certain hypervisors will
      automatically generate a name for the created tun device. This
4160
      name can be manually specified, however the name <i>must not
E
Eric Blake 已提交
4161 4162 4163
      start with either 'vnet' or 'vif'</i>, which are prefixes
      reserved by libvirt and certain hypervisors. Manually specified
      targets using these prefixes will be ignored.
4164 4165
    </p>

4166 4167 4168 4169 4170 4171 4172 4173 4174 4175 4176 4177 4178 4179 4180 4181 4182
    <p>
      Note that for LXC containers, this defines the name of the interface
      on the host side. <span class="since">Since 1.2.7</span>, to define
      the name of the device on the guest side, the <code>guest</code>
      element should be used, as in the following snippet:
    </p>

<pre>
  ...
  &lt;devices&gt;
    &lt;interface type='network'&gt;
      &lt;source network='default'/&gt;
      <b>&lt;guest dev='myeth'/&gt;</b>
    &lt;/interface&gt;
  &lt;/devices&gt;
  ...</pre>

4183 4184 4185 4186 4187 4188 4189 4190 4191 4192 4193 4194 4195 4196
    <h5><a name="elementsNICSBoot">Specifying boot order</a></h5>

<pre>
  ...
  &lt;devices&gt;
    &lt;interface type='network'&gt;
      &lt;source network='default'/&gt;
      &lt;target dev='vnet1'/&gt;
      <b>&lt;boot order='1'/&gt;</b>
    &lt;/interface&gt;
  &lt;/devices&gt;
  ...</pre>

    <p>
4197
      For hypervisors which support this, you can set a specific NIC to
4198 4199 4200 4201 4202 4203 4204 4205
      be used for network boot. The <code>order</code> attribute determines
      the order in which devices will be tried during boot sequence. The
      per-device <code>boot</code> elements cannot be used together with
      general boot elements in
      <a href="#elementsOSBIOS">BIOS bootloader</a> section.
      <span class="since">Since 0.8.8</span>
    </p>

4206 4207 4208 4209 4210 4211 4212 4213
    <h5><a name="elementsNICSROM">Interface ROM BIOS configuration</a></h5>

<pre>
  ...
  &lt;devices&gt;
    &lt;interface type='network'&gt;
      &lt;source network='default'/&gt;
      &lt;target dev='vnet1'/&gt;
4214
      <b>&lt;rom bar='on' file='/etc/fake/boot.bin'/&gt;</b>
4215 4216 4217 4218 4219 4220 4221 4222 4223 4224 4225 4226 4227
    &lt;/interface&gt;
  &lt;/devices&gt;
  ...</pre>

    <p>
      For hypervisors which support this, you can change how a PCI Network
      device's ROM is presented to the guest. The <code>bar</code>
      attribute can be set to "on" or "off", and determines whether
      or not the device's ROM will be visible in the guest's memory
      map. (In PCI documentation, the "rombar" setting controls the
      presence of the Base Address Register for the ROM). If no rom
      bar is specified, the qemu default will be used (older
      versions of qemu used a default of "off", while newer qemus
4228 4229 4230 4231 4232 4233
      have a default of "on").
      The optional <code>file</code> attribute is used to point to a
      binary file to be presented to the guest as the device's ROM
      BIOS. This can be useful to provide an alternative boot ROM for a
      network device.
      <span class="since">Since 0.9.10 (QEMU and KVM only)</span>.
4234 4235
    </p>

4236 4237 4238 4239 4240 4241 4242 4243 4244
    <h5><a name="elementQoS">Quality of service</a></h5>

<pre>
  ...
  &lt;devices&gt;
    &lt;interface type='network'&gt;
      &lt;source network='default'/&gt;
      &lt;target dev='vnet0'/&gt;
      <b>&lt;bandwidth&gt;
4245
        &lt;inbound average='1000' peak='5000' floor='200' burst='1024'/&gt;
4246 4247 4248
        &lt;outbound average='128' peak='256' burst='256'/&gt;
      &lt;/bandwidth&gt;</b>
    &lt;/interface&gt;
M
Michele Paolino 已提交
4249
  &lt;/devices&gt;
4250 4251 4252 4253
  ...</pre>

    <p>
      This part of interface XML provides setting quality of service. Incoming
J
John Ferlan 已提交
4254 4255 4256 4257
      and outgoing traffic can be shaped independently.
      The <code>bandwidth</code> element and its child elements are described
      in the <a href="formatnetwork.html#elementQoS">QoS</a> section of
      the Network XML.
4258 4259
    </p>

4260 4261 4262 4263 4264 4265 4266 4267 4268 4269 4270 4271 4272 4273
    <h5><a name="elementVlanTag">Setting VLAN tag (on supported network types only)</a></h5>

<pre>
  ...
  &lt;devices&gt;
    &lt;interface type='bridge'&gt;
      <b>&lt;vlan&gt;</b>
        <b>&lt;tag id='42'/&gt;</b>
      <b>&lt;/vlan&gt;</b>
      &lt;source bridge='ovsbr0'/&gt;
      &lt;virtualport type='openvswitch'&gt;
        &lt;parameters interfaceid='09b11c53-8b5c-4eeb-8f00-d84eaa0aaa4f'/&gt;
      &lt;/virtualport&gt;
    &lt;/interface&gt;
4274 4275 4276 4277 4278 4279 4280
    &lt;interface type='bridge'&gt;
      <b>&lt;vlan trunk='yes'&gt;</b>
        <b>&lt;tag id='42'/&gt;</b>
        <b>&lt;tag id='123' nativeMode='untagged'/&gt;</b>
      <b>&lt;/vlan&gt;</b>
      ...
    &lt;/interface&gt;
M
Michele Paolino 已提交
4281
  &lt;/devices&gt;
4282 4283 4284 4285 4286 4287 4288 4289 4290 4291 4292 4293 4294 4295 4296
  ...</pre>

    <p>
      If (and only if) the network connection used by the guest
      supports vlan tagging transparent to the guest, an
      optional <code>&lt;vlan&gt;</code> element can specify one or
      more vlan tags to apply to the guest's network
      traffic <span class="since">Since 0.10.0</span>. (openvswitch
      and type='hostdev' SR-IOV interfaces do support transparent vlan
      tagging of guest traffic; everything else, including standard
      linux bridges and libvirt's own virtual networks, <b>do not</b>
      support it. 802.1Qbh (vn-link) and 802.1Qbg (VEPA) switches
      provide their own way (outside of libvirt) to tag guest traffic
      onto specific vlans.) To allow for specification of multiple
      tags (in the case of vlan trunking), a
P
Philipp Hahn 已提交
4297
      subelement, <code>&lt;tag&gt;</code>, specifies which vlan tag
4298 4299 4300 4301 4302 4303 4304 4305 4306
      to use (for example: <code>&lt;tag id='42'/&gt;</code>. If an
      interface has more than one <code>&lt;vlan&gt;</code> element
      defined, it is assumed that the user wants to do VLAN trunking
      using all the specified tags. In the case that vlan trunking
      with a single tag is desired, the optional
      attribute <code>trunk='yes'</code> can be added to the toplevel
      vlan element.
    </p>

4307 4308 4309
    <p>
      For network connections using openvswitch it is possible to
      configure the 'native-tagged' and 'native-untagged' vlan modes
4310
      <span class="since">Since 1.1.0.</span> This uses the optional
4311 4312
      <code>nativeMode</code> attribute on the <code>&lt;tag&gt;</code>
      element: <code>nativeMode</code> may be set to 'tagged' or
4313
      'untagged'. The id attribute of the element sets the native vlan.
4314 4315
    </p>

4316
    <h5><a name="elementLink">Modifying virtual link state</a></h5>
4317 4318 4319 4320 4321 4322 4323 4324
<pre>
  ...
  &lt;devices&gt;
    &lt;interface type='network'&gt;
      &lt;source network='default'/&gt;
      &lt;target dev='vnet0'/&gt;
      <b>&lt;link state='down'/&gt;</b>
    &lt;/interface&gt;
M
Michele Paolino 已提交
4325
  &lt;/devices&gt;
4326 4327 4328 4329 4330 4331 4332 4333 4334 4335 4336
  ...</pre>

    <p>
      This element provides means of setting state of the virtual network link.
      Possible values for attribute <code>state</code> are <code>up</code> and
      <code>down</code>. If <code>down</code> is specified as the value, the interface
      behaves as if it had the network cable disconnected. Default behavior if this
      element is unspecified is to have the link state <code>up</code>.
      <span class="since">Since 0.9.5</span>
    </p>

4337 4338 4339 4340 4341 4342 4343
    <h5><a name="ipconfig">IP configuration</a></h5>
<pre>
  ...
  &lt;devices&gt;
    &lt;interface type='network'&gt;
      &lt;source network='default'/&gt;
      &lt;target dev='vnet0'/&gt;
4344 4345 4346
      <b>&lt;ip address='192.168.122.5' prefix='24'/&gt;</b>
      <b>&lt;route family='ipv4' address='192.168.122.0' prefix='24' via='192.168.122.1'/&gt;</b>
      <b>&lt;route family='ipv4' via='192.168.122.1'/&gt;</b>
4347
    &lt;/interface&gt;
4348 4349 4350 4351 4352
    ...
    &lt;hostdev mode='capabilities' type='net'&gt;
      &lt;source&gt;
        &lt;interface&gt;eth0&lt;/interface&gt;
      &lt;/source&gt;
4353 4354 4355
      <b>&lt;ip address='192.168.122.6' prefix='24'/&gt;</b>
      <b>&lt;route family='ipv4' address='192.168.122.0' prefix='24' via='192.168.122.1'/&gt;</b>
      <b>&lt;route family='ipv4' via='192.168.122.1'/&gt;</b>
4356 4357
    &lt;/hostdev&gt;

4358 4359 4360 4361 4362 4363 4364 4365 4366 4367 4368 4369 4370 4371
  &lt;/devices&gt;
  ...
</pre>

    <p>
    <span class="since">Since 1.2.12</span> the network devices and host devices
    with network capabilities can be provided zero or more IP addresses to set
    on the target device. Note that some hypervisors or network device types
    will simply ignore them or only use the first one. The <code>family</code>
    attribute can be set to either <code>ipv4</code> or <code>ipv6</code>, the
    <code>address</code> attribute holds the IP address. The <code>prefix</code>
    is not mandatory since some hypervisors do not handle it.
    </p>

4372 4373 4374 4375 4376 4377 4378 4379 4380 4381 4382
    <p>
    <span class="since">Since 1.2.12</span> route elements can also be added
    to define the network routes to use for the network device. This element
    has a <code>family</code> attribute set either to <code>ipv4</code> or
    <code>ipv6</code>, a mandatory <code>via</code> attribute defining the
    IP address to route throught and optional <code>address</code> and <code>prefix</code>
    attributes defining the target network range. If those aren't given, then
    a default route will be set.
    This is only used by the LXC driver.
    </p>

M
Michele Paolino 已提交
4383 4384 4385 4386 4387 4388 4389 4390 4391 4392 4393 4394 4395 4396 4397 4398 4399 4400 4401 4402 4403 4404 4405 4406 4407 4408 4409 4410 4411 4412 4413
    <h5><a name="elementVhostuser">vhost-user interface</a></h5>

    <p>
    <span class="since">Since 1.2.7</span> the vhost-user enables the
    communication between a QEMU virtual machine and other userspace process
    using the Virtio transport protocol.  A char dev (e.g. Unix socket) is used
    for the control plane, while the data plane is based on shared memory.
    </p>

<pre>
  ...
  &lt;devices&gt;
    &lt;interface type='vhostuser'&gt;
      &lt;mac address='52:54:00:3b:83:1a'/&gt;
      &lt;source type='unix' path='/tmp/vhost.sock' mode='server'/&gt;
      &lt;model type='virtio'/&gt;
    &lt;/interface&gt;
  &lt;/devices&gt;
  ...</pre>

    <p>
      The <code>&lt;source&gt;</code> element has to be specified
      along with the type of char device.
      Currently, only type='unix' is supported, where the path (the
      directory path of the socket) and mode attributes are required.
      Both <code>mode='server'</code> and <code>mode='client'</code>
      are supported.
      vhost-user requires the virtio model type, thus the
      <code>&lt;model&gt;</code> element is mandatory.
    </p>

D
Daniel P. Berrange 已提交
4414 4415 4416
    <h4><a name="elementsInput">Input devices</a></h4>

    <p>
E
Eric Blake 已提交
4417 4418 4419 4420
      Input devices allow interaction with the graphical framebuffer
      in the guest virtual machine. When enabling the framebuffer, an
      input device is automatically provided. It may be possible to
      add additional devices explicitly, for example,
D
Daniel P. Berrange 已提交
4421 4422 4423
      to provide a graphics tablet for absolute cursor movement.
    </p>

4424 4425 4426 4427
<pre>
  ...
  &lt;devices&gt;
    &lt;input type='mouse' bus='usb'/&gt;
4428
    &lt;input type='keyboard' bus='usb'/&gt;
4429 4430
  &lt;/devices&gt;
  ...</pre>
D
Daniel P. Berrange 已提交
4431 4432 4433

    <dl>
      <dt><code>input</code></dt>
E
Eric Blake 已提交
4434
      <dd>The <code>input</code> element has one mandatory attribute,
4435 4436 4437 4438
        the <code>type</code> whose value can be 'mouse', 'tablet' or
        (<span class="since">since 1.2.2</span>) 'keyboard'.
        The tablet provides absolute cursor movement,
        while the mouse uses relative movement. The optional
M
Matthew Booth 已提交
4439 4440
        <code>bus</code> attribute can be used to refine the exact device type.
        It takes values "xen" (paravirtualized), "ps2" and "usb".</dd>
D
Daniel P. Berrange 已提交
4441 4442
    </dl>

E
Eric Blake 已提交
4443 4444 4445
    <p>
      The <code>input</code> element has an optional
      sub-element <code>&lt;address&gt;</code> which can tie the
4446 4447
      device to a particular PCI
      slot, <a href="#elementsAddress">documented above</a>.
E
Eric Blake 已提交
4448
    </p>
D
Daniel P. Berrange 已提交
4449

M
Marc-André Lureau 已提交
4450 4451 4452 4453 4454 4455 4456 4457 4458 4459 4460 4461 4462 4463 4464 4465 4466 4467 4468 4469 4470 4471 4472
    <h4><a name="elementsHub">Hub devices</a></h4>

    <p>
      A hub is a device that expands a single port into several so
      that there are more ports available to connect devices to a host
      system.
    </p>

<pre>
  ...
  &lt;devices&gt;
    &lt;hub type='usb'/&gt;
  &lt;/devices&gt;
  ...</pre>

    <dl>
      <dt><code>hub</code></dt>
      <dd>The <code>hub</code> element has one mandatory attribute,
        the <code>type</code> whose value can only be 'usb'.</dd>
    </dl>

    <p>
      The <code>hub</code> element has an optional
4473 4474 4475 4476
      sub-element <code>&lt;address&gt;</code>
      with <code>type='usb'</code>which can tie the device to a
      particular controller, <a href="#elementsAddress">documented
      above</a>.
M
Marc-André Lureau 已提交
4477 4478
    </p>

D
Daniel P. Berrange 已提交
4479 4480 4481 4482 4483 4484 4485 4486 4487
    <h4><a name="elementsGraphics">Graphical framebuffers</a></h4>

    <p>
      A graphics device allows for graphical interaction with the
      guest OS. A guest will typically have either a framebuffer
      or a text console configured to allow interaction with the
      admin.
    </p>

4488 4489 4490 4491
<pre>
  ...
  &lt;devices&gt;
    &lt;graphics type='sdl' display=':0.0'/&gt;
4492
    &lt;graphics type='vnc' port='5904' sharePolicy='allow-exclusive'&gt;
4493 4494
      &lt;listen type='address' address='1.2.3.4'/&gt;
    &lt;/graphics&gt;
4495 4496
    &lt;graphics type='rdp' autoport='yes' multiUser='yes' /&gt;
    &lt;graphics type='desktop' fullscreen='yes'/&gt;
4497 4498 4499
    &lt;graphics type='spice'&gt;
      &lt;listen type='network' network='rednet'/&gt;
    &lt;/graphics&gt;
4500 4501
  &lt;/devices&gt;
  ...</pre>
D
Daniel P. Berrange 已提交
4502 4503 4504 4505

    <dl>
      <dt><code>graphics</code></dt>
      <dd>The <code>graphics</code> element has a mandatory <code>type</code>
E
Eric Blake 已提交
4506
        attribute which takes the value "sdl", "vnc", "rdp" or "desktop":
4507 4508 4509
        <dl>
          <dt><code>"sdl"</code></dt>
          <dd>
E
Eric Blake 已提交
4510 4511 4512 4513 4514 4515
            This displays a window on the host desktop, it can take 3
            optional arguments: a <code>display</code> attribute for
            the display to use, an <code>xauth</code> attribute for
            the authentication identifier, and an
            optional <code>fullscreen</code> attribute accepting
            values 'yes' or 'no'.
4516 4517 4518
          </dd>
          <dt><code>"vnc"</code></dt>
          <dd>
E
Eric Blake 已提交
4519 4520 4521 4522 4523 4524 4525 4526 4527 4528 4529 4530
            Starts a VNC server. The <code>port</code> attribute
            specifies the TCP port number (with -1 as legacy syntax
            indicating that it should be
            auto-allocated). The <code>autoport</code> attribute is
            the new preferred syntax for indicating autoallocation of
            the TCP port to use.  The <code>listen</code> attribute is
            an IP address for the server to listen
            on. The <code>passwd</code> attribute provides a VNC
            password in clear text. The <code>keymap</code> attribute
            specifies the keymap to use. It is possible to set a limit
            on the validity of the password be giving an
            timestamp <code>passwdValidTo='2010-04-09T15:51:00'</code>
4531 4532 4533 4534
            assumed to be in UTC. The <code>connected</code> attribute
            allows control of connected client during password changes.
            VNC accepts <code>keep</code> value only.
            <span class="since">since 0.9.3</span>
4535 4536 4537 4538 4539 4540 4541 4542 4543 4544
            NB, this may not be supported by all hypervisors.<br/>
            The optional <code>sharePolicy</code> attribute specifies vnc server
            display sharing policy. "allow-exclusive" allows clients to ask
            for exclusive access by dropping other connections. Connecting
            multiple clients in parallel requires all clients asking for a
            shared session (vncviewer: -Shared switch). This is the default
            value. "force-shared" disables exclusive client access, every
            connection has to specify -Shared switch for vncviewer. "ignore"
            welcomes every connection unconditionally
            <span class="since">since 1.0.6</span>. <br/> <br/>
4545 4546 4547
            Rather than using listen/port, QEMU supports a
            <code>socket</code> attribute for listening on a unix
            domain socket path.<span class="since">Since 0.8.8</span>
M
Martin Kletzander 已提交
4548 4549 4550 4551 4552 4553

            For VNC WebSocket functionality, <code>websocket</code>
            attribute may be used to specify port to listen on (with
            -1 meaning auto-allocation and <code>autoport</code>
            having no effect due to security reasons).
            <span class="since">Since 1.0.6</span>
4554 4555 4556
          </dd>
          <dt><code>"spice"</code></dt>
          <dd>
E
Eric Blake 已提交
4557
            <p>
E
Eric Blake 已提交
4558 4559 4560 4561 4562 4563
              Starts a SPICE server. The <code>port</code> attribute
              specifies the TCP port number (with -1 as legacy syntax
              indicating that it should be auto-allocated),
              while <code>tlsPort</code> gives an alternative secure
              port number. The <code>autoport</code> attribute is the
              new preferred syntax for indicating autoallocation of
4564
              needed port numbers.  The <code>listen</code> attribute is
E
Eric Blake 已提交
4565 4566 4567 4568 4569 4570
              an IP address for the server to listen
              on. The <code>passwd</code> attribute provides a SPICE
              password in clear text. The <code>keymap</code>
              attribute specifies the keymap to use. It is possible to
              set a limit on the validity of the password be giving an
              timestamp <code>passwdValidTo='2010-04-09T15:51:00'</code>
4571 4572 4573 4574 4575 4576 4577 4578
              assumed to be in UTC. The <code>connected</code> attribute
              allows control of connected client during password changes.
              SPICE accepts <code>keep</code> to keep client connected,
              <code>disconnect</code> to disconnect client and
              <code>fail</code> to fail changing password.
              <span class="since">Since 0.9.3</span>
              NB, this may not be supported by all hypervisors.
              <span class="since">"spice" since 0.8.6</span>.
4579 4580 4581 4582 4583 4584 4585
              The <code>defaultMode</code> attribute sets the default channel
              security policy, valid values are <code>secure</code>,
              <code>insecure</code> and the default <code>any</code>
              (which is secure if possible, but falls back to insecure
              rather than erroring out if no secure path is
              available). <span class="since">"defaultMode" since
              0.9.12</span>.
E
Eric Blake 已提交
4586 4587
            </p>
            <p>
E
Eric Blake 已提交
4588 4589 4590 4591
              When SPICE has both a normal and TLS secured TCP port
              configured, it can be desirable to restrict what
              channels can be run on each port.  This is achieved by
              adding one or more &lt;channel&gt; elements inside the
4592 4593 4594 4595 4596 4597 4598
              main &lt;graphics&gt; element and setting the <code>mode</code>
              attribute to either <code>secure</code> or <code>insecure</code>.
              Setting the mode attribute overrides the default value as set
              by the <code>defaultMode</code> attribute. (Note that specifying
              <code>any</code> as mode discards the entry as the channel would
              inherit the default mode anyways)
              Valid channel names
E
Eric Blake 已提交
4599 4600
              include <code>main</code>, <code>display</code>,
              <code>inputs</code>, <code>cursor</code>,
4601 4602 4603 4604 4605
              <code>playback</code>, <code>record</code>
              (all <span class="since"> since 0.8.6</span>);
              <code>smartcard</code> (<span class="since">since
              0.8.8</span>); and <code>usbredir</code>
              (<span class="since">since 0.9.12</span>).
E
Eric Blake 已提交
4606 4607
            </p>
            <pre>
4608 4609 4610
  &lt;graphics type='spice' port='-1' tlsPort='-1' autoport='yes'&gt;
    &lt;channel name='main' mode='secure'/&gt;
    &lt;channel name='record' mode='insecure'/&gt;
4611
    &lt;image compression='auto_glz'/&gt;
4612
    &lt;streaming mode='filter'/&gt;
4613
    &lt;clipboard copypaste='no'/&gt;
P
Peng Zhou 已提交
4614
    &lt;mouse mode='client'/&gt;
4615
    &lt;filetransfer enable='no'/&gt;
4616
  &lt;/graphics&gt;</pre>
4617 4618 4619 4620 4621 4622 4623 4624 4625 4626 4627 4628 4629 4630 4631 4632 4633
            <p>
              Spice supports variable compression settings for audio,
              images and streaming, <span class="since">since
              0.9.1</span>.  These settings are accessible via
              the <code>compression</code> attribute in all following
              elements: <code>image</code> to set image compression
              (accepts <code>auto_glz</code>, <code>auto_lz</code>,
              <code>quic</code>, <code>glz</code>, <code>lz</code>,
              <code>off</code>), <code>jpeg</code> for JPEG
              compression for images over wan
              (accepts <code>auto</code>, <code>never</code>,
              <code>always</code>), <code>zlib</code> for configuring
              wan image compression (accepts <code>auto</code>,
              <code>never</code>, <code>always</code>)
              and <code>playback</code> for enabling audio stream
              compression (accepts <code>on</code> or <code>off</code>).
            </p>
4634 4635
            <p>
              Streaming mode is set by the <code>streaming</code>
Z
Zhou Peng 已提交
4636
              element, settings its <code>mode</code> attribute to one
4637 4638 4639
              of <code>filter</code>, <code>all</code>
              or <code>off</code>, <span class="since">since 0.9.2</span>.
            </p>
4640 4641 4642 4643 4644 4645 4646
            <p>
              Copy &amp; Paste functionality (via Spice agent) is set
              by the <code>clipboard</code> element. It is enabled by
              default, and can be disabled by setting
              the <code>copypaste</code> property
              to <code>no</code>, <span class="since">since
              0.9.3</span>.
4647
            </p>
P
Peng Zhou 已提交
4648
            <p>
Z
Zhou Peng 已提交
4649 4650
              Mouse mode is set by the <code>mouse</code> element,
              setting its <code>mode</code> attribute to one of
P
Peng Zhou 已提交
4651 4652 4653 4654
              <code>server</code> or <code>client</code> ,
              <span class="since">since 0.9.11</span>. If no mode is
              specified, the qemu default will be used (client mode).
            </p>
4655 4656 4657 4658 4659 4660 4661
            <p>
              File transfer functionality (via Spice agent) is set using the
              <code>filetransfer</code> element.
              It is enabled by default, and can be disabled by setting the
              <code>enable</code> property to <code>no</code> ,
              since <span class="since">since 1.2.2</span>.
            </p>
4662 4663 4664
          </dd>
          <dt><code>"rdp"</code></dt>
          <dd>
E
Eric Blake 已提交
4665 4666 4667 4668 4669 4670 4671 4672
            Starts a RDP server. The <code>port</code> attribute
            specifies the TCP port number (with -1 as legacy syntax
            indicating that it should be
            auto-allocated). The <code>autoport</code> attribute is
            the new preferred syntax for indicating autoallocation of
            the TCP port to use. The <code>replaceUser</code>
            attribute is a boolean deciding whether multiple
            simultaneous connections to the VM are permitted.
4673 4674 4675 4676
            The <code>multiUser</code> attribute is a boolean deciding
            whether the existing connection must be dropped and a new
            connection must be established by the VRDP server, when a
            new client connects in single connection mode.
4677 4678 4679
          </dd>
          <dt><code>"desktop"</code></dt>
          <dd>
E
Eric Blake 已提交
4680 4681 4682 4683 4684 4685
            This value is reserved for VirtualBox domains for the
            moment. It displays a window on the host desktop,
            similarly to "sdl", but using the VirtualBox viewer. Just
            like "sdl", it accepts the optional
            attributes <code>display</code>
            and <code>fullscreen</code>.
4686 4687 4688 4689 4690
          </dd>
        </dl>
      </dd>
    </dl>

4691 4692 4693 4694 4695 4696 4697 4698 4699 4700 4701 4702 4703 4704 4705 4706 4707 4708 4709 4710 4711 4712 4713 4714 4715 4716 4717 4718 4719 4720 4721 4722 4723 4724 4725 4726 4727 4728 4729 4730 4731 4732 4733 4734 4735 4736 4737 4738
    <p>
      Rather than putting the address information used to set up the
      listening socket for graphics types <code>vnc</code>
      and <code>spice</code> in
      the <code>&lt;graphics&gt;</code> <code>listen</code> attribute,
      a separate subelement of <code>&lt;graphics&gt;</code>,
      called <code>&lt;listen&gt;</code> can be specified (see the
      examples above)<span class="since">since
      0.9.4</span>. <code>&lt;listen&gt;</code> accepts the following
      attributes:
    </p>
    <dl>
      <dt><code>type</code></dt>
      <dd>Set to either <code>address</code>
        or <code>network</code>. This tells whether this listen
        element is specifying the address to be used directly, or by
        naming a network (which will then be used to determine an
        appropriate address for listening).
      </dd>
    </dl>
    <dl>
      <dt><code>address</code></dt>
      <dd>if <code>type='address'</code>, the <code>address</code>
        attribute will contain either an IP address or hostname (which
        will be resolved to an IP address via a DNS query) to listen
        on. In the "live" XML of a running domain, this attribute will
        be set to the IP address used for listening, even
        if <code>type='network'</code>.
      </dd>
    </dl>
    <dl>
      <dt><code>network</code></dt>
      <dd>if <code>type='network'</code>, the <code>network</code>
        attribute will contain the name of a network in libvirt's list
        of configured networks. The named network configuration will
        be examined to determine an appropriate listen address. For
        example, if the network has an IPv4 address in its
        configuration (e.g. if it has a forward type
        of <code>route</code>, <code>nat</code>, or no forward type
        (isolated)), the first IPv4 address listed in the network's
        configuration will be used. If the network is describing a
        host bridge, the first IPv4 address associated with that
        bridge device will be used, and if the network is describing
        one of the 'direct' (macvtap) modes, the first IPv4 address of
        the first forward dev will be used.
      </dd>
    </dl>

4739 4740 4741 4742 4743
    <h4><a name="elementsVideo">Video devices</a></h4>
    <p>
      A video device.
    </p>

4744 4745 4746 4747
<pre>
  ...
  &lt;devices&gt;
    &lt;video&gt;
4748
      &lt;model type='vga' vram='16384' heads='1'&gt;
4749
        &lt;acceleration accel3d='yes' accel2d='yes'/&gt;
4750 4751 4752 4753
      &lt;/model&gt;
    &lt;/video&gt;
  &lt;/devices&gt;
  ...</pre>
4754 4755 4756

    <dl>
      <dt><code>video</code></dt>
4757
      <dd>
4758 4759 4760 4761 4762 4763 4764 4765 4766 4767 4768 4769 4770 4771 4772 4773
        <p>
          The <code>video</code> element is the container for describing
          video devices. For backwards compatibility, if no <code>video</code>
          is set but there is a <code>graphics</code> in domain xml, then
          libvirt will add a default <code>video</code> according to the guest
          type.
        </p>
        <p>
          For a guest of type "kvm", the default <code>video</code> is:
          <code>type</code> with value "cirrus", <code>vram</code> with value
          "16384" and <code>heads</code> with value "1". By default, the first
          video device in domain xml is the primary one, but the optional
          attribute <code>primary</code> (<span class="since">since 1.0.2</span>)
          with value 'yes' can be used to mark the primary in cases of multiple
          video device. The non-primary must be type of "qxl".
        </p>
4774
      </dd>
4775

4776 4777
      <dt><code>model</code></dt>
      <dd>
4778 4779 4780 4781 4782 4783 4784 4785 4786 4787 4788 4789 4790 4791 4792 4793 4794 4795 4796 4797 4798 4799 4800
        <p>
          The <code>model</code> element has a mandatory <code>type</code>
          attribute which takes the value "vga", "cirrus", "vmvga", "xen",
          "vbox", or "qxl" (<span class="since">since 0.8.6</span>) depending
          on the hypervisor features available.
        </p>
        <p>
          You can provide the amount of video memory in kibibytes (blocks of
          1024 bytes) using <code>vram</code>. This is supported only for guest
          type of "libxl", "parallels", "qemu", "vbox", "vmx" and "xen". If no
          value is provided the default is used. If the size is not a power of
          two it will be rounded to closest one.
        </p>
        <p>
          The number of screen can be set using <code>heads</code>. This is
          supported only for guests type of "parallels", "kvm", "vbox" and "vmx".
        </p>
        <p>
          For guest type of kvm the optional attribute <code>ram</code>
          (<span class="since">since 1.0.2</span>) is allowed for "qxl" type
          only and specifies the size of the primary bar, while the optional
          attribute <code>vram</code> specifies the secondary bar size.
          If "ram" or "vram" are not supplied a default value is used. The ram
4801 4802 4803 4804
          should also be rounded to power of two as vram. There is also optional
          attribute <code>vgamem</code> (<span class="since">since 1.2.11 (QEMU
          only)</span>) to set the size of VGA framebuffer for fallback mode of
          QXL device.
4805
        </p>
4806 4807 4808 4809 4810 4811 4812 4813
      </dd>

      <dt><code>acceleration</code></dt>
      <dd>
        If acceleration should be enabled (if supported) using the
        <code>accel3d</code> and <code>accel2d</code> attributes in the
        <code>acceleration</code> element.
      </dd>
E
Eric Blake 已提交
4814 4815 4816 4817 4818 4819

      <dt><code>address</code></dt>
      <dd>
        The optional <code>address</code> sub-element can be used to
        tie the video device to a particular PCI slot.
      </dd>
D
Daniel P. Berrange 已提交
4820 4821
    </dl>

4822
    <h4><a name="elementsConsole">Consoles, serial, parallel &amp; channel devices</a></h4>
D
Daniel P. Berrange 已提交
4823 4824 4825

    <p>
      A character device provides a way to interact with the virtual machine.
4826 4827
      Paravirtualized consoles, serial ports, parallel ports and channels are
      all classed as character devices and so represented using the same syntax.
D
Daniel P. Berrange 已提交
4828 4829
    </p>

4830 4831 4832 4833 4834 4835 4836 4837 4838 4839 4840
<pre>
  ...
  &lt;devices&gt;
    &lt;parallel type='pty'&gt;
      &lt;source path='/dev/pts/2'/&gt;
      &lt;target port='0'/&gt;
    &lt;/parallel&gt;
    &lt;serial type='pty'&gt;
      &lt;source path='/dev/pts/3'/&gt;
      &lt;target port='0'/&gt;
    &lt;/serial&gt;
4841
    &lt;serial type='file'&gt;
4842 4843 4844
      &lt;source path='/tmp/file'&gt;
        &lt;seclabel model='dac' relabel='no'/&gt;
      &lt;/source&gt;
4845
      &lt;target port='0'/&gt;
4846
    &lt;/serial&gt;
4847 4848 4849 4850 4851 4852 4853 4854 4855 4856
    &lt;console type='pty'&gt;
      &lt;source path='/dev/pts/4'/&gt;
      &lt;target port='0'/&gt;
    &lt;/console&gt;
    &lt;channel type='unix'&gt;
      &lt;source mode='bind' path='/tmp/guestfwd'/&gt;
      &lt;target type='guestfwd' address='10.0.2.1' port='4600'/&gt;
    &lt;/channel&gt;
  &lt;/devices&gt;
  ...</pre>
D
Daniel P. Berrange 已提交
4857

4858 4859 4860 4861 4862
    <p>
      In each of these directives, the top-level element name (parallel, serial,
      console, channel) describes how the device is presented to the guest. The
      guest interface is configured by the <code>target</code> element.
    </p>
D
Daniel P. Berrange 已提交
4863

4864 4865 4866 4867 4868 4869
    <p>
      The interface presented to the host is given in the <code>type</code>
      attribute of the top-level element. The host interface is
      configured by the <code>source</code> element.
    </p>

4870 4871 4872 4873 4874 4875 4876 4877
    <p>
      The <code>source</code> element may contain an optional
      <code>seclabel</code> to override the way that labelling
      is done on the socket path.  If this element is not present,
      the <a href="#seclabel">security label is inherited from
        the per-domain setting</a>.
    </p>

E
Eric Blake 已提交
4878 4879 4880 4881 4882 4883 4884 4885
    <p>
      Each character device element has an optional
      sub-element <code>&lt;address&gt;</code> which can tie the
      device to a
      particular <a href="#elementsControllers">controller</a> or PCI
      slot.
    </p>

4886 4887 4888 4889 4890 4891 4892 4893 4894
    <h5><a name="elementsCharGuestInterface">Guest interface</a></h5>

    <p>
      A character device presents itself to the guest as one of the following
      types.
    </p>

    <h6><a name="elementCharParallel">Parallel port</a></h6>

4895 4896 4897 4898 4899 4900 4901 4902 4903
<pre>
  ...
  &lt;devices&gt;
    &lt;parallel type='pty'&gt;
      &lt;source path='/dev/pts/2'/&gt;
      &lt;target port='0'/&gt;
    &lt;/parallel&gt;
  &lt;/devices&gt;
  ...</pre>
4904 4905 4906

    <p>
      <code>target</code> can have a <code>port</code> attribute, which
4907
      specifies the port number. Ports are numbered starting from 0. There are
4908 4909 4910 4911 4912
      usually 0, 1 or 2 parallel ports.
    </p>

    <h6><a name="elementCharSerial">Serial port</a></h6>

4913 4914 4915 4916 4917 4918 4919 4920 4921
<pre>
  ...
  &lt;devices&gt;
    &lt;serial type='pty'&gt;
      &lt;source path='/dev/pts/3'/&gt;
      &lt;target port='0'/&gt;
    &lt;/serial&gt;
  &lt;/devices&gt;
  ...</pre>
4922 4923 4924

    <p>
      <code>target</code> can have a <code>port</code> attribute, which
4925
      specifies the port number. Ports are numbered starting from 0. There are
G
Guannan Ren 已提交
4926 4927
      usually 0, 1 or 2 serial ports. There is also an optional
      <code>type</code> attribute <span class="since">since 1.0.2</span>
4928
      which has two choices for its value, one is <code>isa-serial</code>,
G
Guannan Ren 已提交
4929 4930 4931 4932 4933
      the other is <code>usb-serial</code>. If <code>type</code> is missing,
      <code>isa-serial</code> will be used by default. For <code>usb-serial</code>
      an optional sub-element <code>&lt;address&gt;</code> with
      <code>type='usb'</code> can tie the device to a particular controller,
      <a href="#elementsAddress">documented above</a>.
4934 4935 4936 4937 4938
    </p>

    <h6><a name="elementCharConsole">Console</a></h6>

    <p>
4939 4940 4941 4942 4943 4944 4945
      The console element is used to represent interactive consoles. Depending
      on the type of guest in use, the consoles might be paravirtualized devices,
      or they might be a clone of a serial device, according to the following
      rules:
    </p>

    <ul>
4946
      <li>If no <code>targetType</code> attribute is set, then the default
4947 4948 4949 4950 4951 4952 4953 4954 4955 4956 4957 4958 4959
        device type is according to the hypervisor's rules. The default
        type will be added when re-querying the XML fed into libvirt.
        For fully virtualized guests, the default device type will usually
        be a serial port.</li>
      <li>If the <code>targetType</code> attribute is <code>serial</code>,
        then if no <code>&lt;serial&gt;</code> element exists, the console
        element will be copied to the serial element. If a <code>&lt;serial&gt;</code>
        element does already exist, the console element will be ignored.</li>
      <li>If the <code>targetType</code> attribute is not <code>serial</code>,
        it will be treated normally.</li>
      <li>Only the first <code>console</code> element may use a <code>targetType</code>
        of <code>serial</code>. Secondary consoles must all be paravirtualized.
      </li>
4960 4961 4962 4963 4964 4965
      <li>On s390, the <code>console</code> element may use a
        <code>targetType</code> of <code>sclp</code> or <code>sclplm</code>
        (line mode). SCLP is the native console type for s390. There's no
        controller associated to SCLP consoles.
        <span class="since">Since 1.0.2</span>
      </li>
4966
    </ul>
C
Cole Robinson 已提交
4967 4968 4969 4970 4971 4972

    <p>
      A virtio console device is exposed in the
      guest as /dev/hvc[0-7] (for more information, see
      <a href="http://fedoraproject.org/wiki/Features/VirtioSerial">http://fedoraproject.org/wiki/Features/VirtioSerial</a>)
      <span class="since">Since 0.8.3</span>
4973 4974
    </p>

4975 4976 4977 4978 4979 4980 4981
<pre>
  ...
  &lt;devices&gt;
    &lt;console type='pty'&gt;
      &lt;source path='/dev/pts/4'/&gt;
      &lt;target port='0'/&gt;
    &lt;/console&gt;
C
Cole Robinson 已提交
4982 4983 4984 4985 4986 4987

    &lt;!-- KVM virtio console --&gt;
    &lt;console type='pty'&gt;
      &lt;source path='/dev/pts/5'/&gt;
      &lt;target type='virtio' port='0'/&gt;
    &lt;/console&gt;
4988 4989
  &lt;/devices&gt;
  ...</pre>
4990

4991 4992 4993 4994 4995 4996 4997 4998 4999 5000 5001
<pre>
  ...
  &lt;devices&gt;
    &lt;!-- KVM s390 sclp console --&gt;
    &lt;console type='pty'&gt;
      &lt;source path='/dev/pts/1'/&gt;
      &lt;target type='sclp' port='0'/&gt;
    &lt;/console&gt;
  &lt;/devices&gt;
  ...</pre>

5002 5003 5004 5005 5006 5007
    <p>
      If the console is presented as a serial port, the <code>target</code>
      element has the same attributes as for a serial port. There is usually
      only 1 console.
    </p>

5008 5009 5010 5011 5012 5013 5014
    <h6><a name="elementCharChannel">Channel</a></h6>

    <p>
      This represents a private communication channel between the host and the
      guest.
    </p>

5015 5016 5017 5018 5019 5020 5021
<pre>
  ...
  &lt;devices&gt;
    &lt;channel type='unix'&gt;
      &lt;source mode='bind' path='/tmp/guestfwd'/&gt;
      &lt;target type='guestfwd' address='10.0.2.1' port='4600'/&gt;
    &lt;/channel&gt;
5022 5023 5024 5025 5026

    &lt;!-- KVM virtio channel --&gt;
    &lt;channel type='pty'&gt;
      &lt;target type='virtio' name='arbitrary.virtio.serial.port.name'/&gt;
    &lt;/channel&gt;
D
Daniel P. Berrange 已提交
5027 5028
    &lt;channel type='unix'&gt;
      &lt;source mode='bind' path='/var/lib/libvirt/qemu/f16x86_64.agent'/&gt;
5029
      &lt;target type='virtio' name='org.qemu.guest_agent.0' state='connected'/&gt;
D
Daniel P. Berrange 已提交
5030
    &lt;/channel&gt;
5031 5032 5033
    &lt;channel type='spicevmc'&gt;
      &lt;target type='virtio' name='com.redhat.spice.0'/&gt;
    &lt;/channel&gt;
5034 5035
  &lt;/devices&gt;
  ...</pre>
5036 5037 5038 5039 5040 5041 5042 5043 5044 5045 5046 5047 5048 5049

    <p>
      This can be implemented in a variety of ways. The specific type of
      channel is given in the <code>type</code> attribute of the
      <code>target</code> element. Different channel types have different
      <code>target</code> attributes.
    </p>

    <dl>
      <dt><code>guestfwd</code></dt>
      <dd>TCP traffic sent by the guest to a given IP address and port is
        forwarded to the channel device on the host. The <code>target</code>
        element must have <code>address</code> and <code>port</code> attributes.
        <span class="since">Since 0.7.3</span></dd>
5050 5051 5052

      <dt><code>virtio</code></dt>
      <dd>Paravirtualized virtio channel. Channel is exposed in the guest under
E
Eric Blake 已提交
5053
        /dev/vport*, and if the optional element <code>name</code> is specified,
5054
        /dev/virtio-ports/$name (for more info, please see
E
Eric Blake 已提交
5055 5056
        <a href="http://fedoraproject.org/wiki/Features/VirtioSerial">http://fedoraproject.org/wiki/Features/VirtioSerial</a>). The
        optional element <code>address</code> can tie the channel to a
5057 5058
        particular <code>type='virtio-serial'</code>
        controller, <a href="#elementsAddress">documented above</a>.
D
Daniel P. Berrange 已提交
5059 5060 5061 5062
        With qemu, if <code>name</code> is "org.qemu.guest_agent.0",
        then libvirt can interact with a guest agent installed in the
        guest, for actions such as guest shutdown or file system quiescing.
        <span class="since">Since 0.7.7, guest agent interaction
5063
        since 0.9.10</span> Moreover, <span class="since">since 1.0.6</span>
5064 5065 5066 5067
        it is possible to have source path auto generated for virtio unix channels.
        This is very useful in case of a qemu guest agent, where users don't
        usually care about the source path since it's libvirt who talks to
        the guest agent. In case users want to utilize this feature, they should
5068 5069 5070 5071 5072 5073
        leave <code>&lt;source&gt;</code> element out. <span class="since">Since
        1.2.11</span> the active XML for a virtio channel may contain an optional
        <code>state</code> attribute that reflects whether a process in the
        guest is active on the channel. This is an output-only attribute.
        Possible values for the <code>state</code> attribute are
        <code>connected</code> and <code>disconnected</code>.
5074
      </dd>
5075 5076 5077 5078 5079 5080 5081 5082 5083 5084 5085 5086 5087
      <dt><code>spicevmc</code></dt>
      <dd>Paravirtualized SPICE channel. The domain must also have a
        SPICE server as a <a href="#elementsGraphics">graphics
        device</a>, at which point the host piggy-backs messages
        across the <code>main</code> channel.  The <code>target</code>
        element must be present, with
        attribute <code>type='virtio'</code>; an optional
        attribute <code>name</code> controls how the guest will have
        access to the channel, and defaults
        to <code>name='com.redhat.spice.0'</code>.  The
        optional <code>address</code> element can tie the channel to a
        particular <code>type='virtio-serial'</code> controller.
        <span class="since">Since 0.8.8</span></dd>
5088 5089
    </dl>

5090 5091 5092 5093 5094 5095
    <h5><a name="elementsCharHostInterface">Host interface</a></h5>

    <p>
      A character device presents itself to the host as one of the following
      types.
    </p>
D
Daniel P. Berrange 已提交
5096

5097
    <h6><a name="elementsCharSTDIO">Domain logfile</a></h6>
D
Daniel P. Berrange 已提交
5098 5099 5100 5101 5102 5103

    <p>
      This disables all input on the character device, and sends output
      into the virtual machine's logfile
    </p>

5104 5105 5106 5107
<pre>
  ...
  &lt;devices&gt;
    &lt;console type='stdio'&gt;
E
Eric Blake 已提交
5108
      &lt;target port='1'/&gt;
5109 5110 5111
    &lt;/console&gt;
  &lt;/devices&gt;
  ...</pre>
D
Daniel P. Berrange 已提交
5112 5113


5114
    <h6><a name="elementsCharFle">Device logfile</a></h6>
D
Daniel P. Berrange 已提交
5115 5116 5117 5118 5119 5120

    <p>
      A file is opened and all data sent to the character
      device is written to the file.
    </p>

5121 5122 5123 5124 5125 5126 5127 5128 5129
<pre>
  ...
  &lt;devices&gt;
    &lt;serial type="file"&gt;
      &lt;source path="/var/log/vm/vm-serial.log"/&gt;
      &lt;target port="1"/&gt;
    &lt;/serial&gt;
  &lt;/devices&gt;
  ...</pre>
D
Daniel P. Berrange 已提交
5130

5131
    <h6><a name="elementsCharVC">Virtual console</a></h6>
D
Daniel P. Berrange 已提交
5132 5133 5134 5135 5136 5137 5138

    <p>
      Connects the character device to the graphical framebuffer in
      a virtual console. This is typically accessed via a special
      hotkey sequence such as "ctrl+alt+3"
    </p>

5139 5140 5141 5142 5143 5144 5145 5146
<pre>
  ...
  &lt;devices&gt;
    &lt;serial type='vc'&gt;
      &lt;target port="1"/&gt;
    &lt;/serial&gt;
  &lt;/devices&gt;
  ...</pre>
D
Daniel P. Berrange 已提交
5147

5148
    <h6><a name="elementsCharNull">Null device</a></h6>
D
Daniel P. Berrange 已提交
5149 5150 5151 5152 5153 5154

    <p>
      Connects the character device to the void. No data is ever
      provided to the input. All data written is discarded.
    </p>

5155 5156 5157 5158 5159 5160 5161 5162
<pre>
  ...
  &lt;devices&gt;
    &lt;serial type='null'&gt;
      &lt;target port="1"/&gt;
    &lt;/serial&gt;
  &lt;/devices&gt;
  ...</pre>
D
Daniel P. Berrange 已提交
5163

5164
    <h6><a name="elementsCharPTY">Pseudo TTY</a></h6>
D
Daniel P. Berrange 已提交
5165 5166 5167 5168 5169 5170 5171

    <p>
      A Pseudo TTY is allocated using /dev/ptmx. A suitable client
      such as 'virsh console' can connect to interact with the
      serial port locally.
    </p>

5172 5173 5174 5175 5176 5177 5178 5179 5180
<pre>
  ...
  &lt;devices&gt;
    &lt;serial type="pty"&gt;
      &lt;source path="/dev/pts/3"/&gt;
      &lt;target port="1"/&gt;
    &lt;/serial&gt;
  &lt;/devices&gt;
  ...</pre>
D
Daniel P. Berrange 已提交
5181 5182 5183

    <p>
      NB special case if &lt;console type='pty'&gt;, then the TTY
A
Atsushi SAKAI 已提交
5184
      path is also duplicated as an attribute tty='/dev/pts/3'
D
Daniel P. Berrange 已提交
5185 5186 5187 5188
      on the top level &lt;console&gt; tag. This provides compat
      with existing syntax for &lt;console&gt; tags.
    </p>

5189
    <h6><a name="elementsCharHost">Host device proxy</a></h6>
D
Daniel P. Berrange 已提交
5190 5191 5192 5193 5194

    <p>
      The character device is passed through to the underlying
      physical character device. The device types must match,
      eg the emulated serial port should only be connected to
A
Atsushi SAKAI 已提交
5195
      a host serial port - don't connect a serial port to a parallel
D
Daniel P. Berrange 已提交
5196 5197 5198
      port.
    </p>

5199 5200 5201 5202 5203 5204
<pre>
  ...
  &lt;devices&gt;
    &lt;serial type="dev"&gt;
      &lt;source path="/dev/ttyS0"/&gt;
      &lt;target port="1"/&gt;
E
Eric Blake 已提交
5205
    &lt;/serial&gt;
5206 5207
  &lt;/devices&gt;
  ...</pre>
D
Daniel P. Berrange 已提交
5208

5209
    <h6><a name="elementsCharPipe">Named pipe</a></h6>
5210 5211 5212 5213 5214 5215

    <p>
      The character device writes output to a named pipe. See pipe(7) for
      more info.
    </p>

5216 5217 5218 5219 5220 5221 5222 5223 5224
<pre>
  ...
  &lt;devices&gt;
    &lt;serial type="pipe"&gt;
      &lt;source path="/tmp/mypipe"/&gt;
      &lt;target port="1"/&gt;
    &lt;/serial&gt;
  &lt;/devices&gt;
  ...</pre>
5225

5226
    <h6><a name="elementsCharTCP">TCP client/server</a></h6>
D
Daniel P. Berrange 已提交
5227 5228 5229

    <p>
      The character device acts as a TCP client connecting to a
5230
      remote server.
D
Daniel P. Berrange 已提交
5231 5232
    </p>

5233 5234 5235 5236 5237 5238 5239 5240 5241 5242
<pre>
  ...
  &lt;devices&gt;
    &lt;serial type="tcp"&gt;
      &lt;source mode="connect" host="0.0.0.0" service="2445"/&gt;
      &lt;protocol type="raw"/&gt;
      &lt;target port="1"/&gt;
    &lt;/serial&gt;
  &lt;/devices&gt;
   ...</pre>
5243 5244 5245 5246 5247

    <p>
      Or as a TCP server waiting for a client connection.
    </p>

5248 5249 5250 5251 5252 5253 5254 5255 5256 5257
<pre>
  ...
  &lt;devices&gt;
    &lt;serial type="tcp"&gt;
      &lt;source mode="bind" host="127.0.0.1" service="2445"/&gt;
      &lt;protocol type="raw"/&gt;
      &lt;target port="1"/&gt;
    &lt;/serial&gt;
  &lt;/devices&gt;
  ...</pre>
5258 5259

    <p>
E
Eric Blake 已提交
5260 5261 5262
      Alternatively you can use <code>telnet</code> instead
      of <code>raw</code> TCP.  <span class="since">Since 0.8.5</span>
      you can also use <code>telnets</code>
5263
      (secure telnet) and <code>tls</code>.
E
Eric Blake 已提交
5264
    </p>
5265

5266 5267 5268 5269 5270 5271 5272 5273 5274 5275 5276 5277 5278 5279 5280 5281
<pre>
  ...
  &lt;devices&gt;
    &lt;serial type="tcp"&gt;
      &lt;source mode="connect" host="0.0.0.0" service="2445"/&gt;
      &lt;protocol type="telnet"/&gt;
      &lt;target port="1"/&gt;
    &lt;/serial&gt;
    ...
    &lt;serial type="tcp"&gt;
      &lt;source mode="bind" host="127.0.0.1" service="2445"/&gt;
      &lt;protocol type="telnet"/&gt;
      &lt;target port="1"/&gt;
    &lt;/serial&gt;
  &lt;/devices&gt;
  ...</pre>
D
Daniel P. Berrange 已提交
5282

5283
    <h6><a name="elementsCharUDP">UDP network console</a></h6>
D
Daniel P. Berrange 已提交
5284 5285 5286 5287 5288 5289

    <p>
      The character device acts as a UDP netconsole service,
      sending and receiving packets. This is a lossy service.
    </p>

5290 5291 5292 5293 5294 5295 5296 5297 5298 5299
<pre>
  ...
  &lt;devices&gt;
    &lt;serial type="udp"&gt;
      &lt;source mode="bind" host="0.0.0.0" service="2445"/&gt;
      &lt;source mode="connect" host="0.0.0.0" service="2445"/&gt;
      &lt;target port="1"/&gt;
    &lt;/serial&gt;
  &lt;/devices&gt;
  ...</pre>
D
Daniel P. Berrange 已提交
5300

5301
    <h6><a name="elementsCharUNIX">UNIX domain socket client/server</a></h6>
D
Daniel P. Berrange 已提交
5302 5303 5304 5305 5306 5307

    <p>
      The character device acts as a UNIX domain socket server,
      accepting connections from local clients.
    </p>

5308 5309 5310 5311 5312 5313 5314 5315 5316
<pre>
  ...
  &lt;devices&gt;
    &lt;serial type="unix"&gt;
      &lt;source mode="bind" path="/tmp/foo"/&gt;
      &lt;target port="1"/&gt;
    &lt;/serial&gt;
  &lt;/devices&gt;
  ...</pre>
D
Daniel P. Berrange 已提交
5317

5318 5319 5320 5321 5322 5323 5324 5325 5326 5327 5328 5329 5330 5331 5332 5333 5334 5335
    <h6><a name="elementsCharSpiceport">Spice channel</a></h6>

    <p>
      The character device is accessible through spice connection
      under a channel name specified in the <code>channel</code>
      attribute.  <span class="since">Since 1.2.2</span>
    </p>

<pre>
  ...
  &lt;devices&gt;
    &lt;serial type="spiceport"&gt;
      &lt;source channel="org.qemu.console.serial.0"/&gt;
      &lt;target port="1"/&gt;
    &lt;/serial&gt;
  &lt;/devices&gt;
  ...</pre>

5336 5337 5338 5339
    <h6><a name="elementsNmdm">Nmdm device</a></h6>

    <p>
      The nmdm device driver, available on FreeBSD, provides two
C
Chen Hanxiao 已提交
5340
      tty devices connected together by a virtual null modem cable.
5341 5342 5343 5344 5345 5346 5347 5348 5349 5350 5351 5352 5353 5354 5355 5356 5357 5358 5359 5360 5361 5362 5363 5364
      <span class="since">Since 1.2.4</span>
    </p>

<pre>
  ...
  &lt;devices&gt;
    &lt;serial type="nmdm"&gt;
      &lt;source master="/dev/nmdm0A" slave="/dev/nmdm0B"/&gt;
    &lt;/serial&gt;
  &lt;/devices&gt;
  ...</pre>

    <p>
      The <code>source</code> element has these attributes:
    </p>

    <dl>
      <dt><code>master</code></dt>
      <dd>Master device of the pair, that is passed to the hypervisor.</dd>

      <dt><code>slave</code></dt>
      <dd>Slave device of the pair, that is passed to the clients for connection
      to the guest console.</dd>
    </dl>
5365 5366 5367 5368 5369 5370 5371 5372

    <h4><a name="elementsSound">Sound devices</a></h4>

    <p>
      A virtual sound card can be attached to the host via the
      <code>sound</code> element. <span class="since">Since 0.4.3</span>
    </p>

5373 5374 5375 5376 5377 5378
<pre>
  ...
  &lt;devices&gt;
    &lt;sound model='es1370'/&gt;
  &lt;/devices&gt;
  ...</pre>
5379 5380 5381 5382 5383 5384 5385

    <dl>
      <dt><code>sound</code></dt>
      <dd>
        The <code>sound</code> element has one mandatory attribute,
        <code>model</code>, which specifies what real sound device is emulated.
        Valid values are specific to the underlying hypervisor, though typical
5386
        choices are 'es1370', 'sb16', 'ac97', 'ich6' and 'usb'.
5387
        (<span class="since">
5388 5389
         'ac97' only since 0.6.0, 'ich6' only since 0.8.8,
         'usb' only since 1.2.7</span>)
5390 5391 5392
      </dd>
    </dl>

5393 5394 5395 5396 5397 5398 5399 5400 5401 5402 5403 5404 5405 5406 5407
    <p>
      <span class="since">Since 0.9.13</span>, a sound element
      with <code>ich6</code> model can have optional
      sub-elements <code>&lt;codec&gt;</code> to attach various audio
      codecs to the audio device. If not specified, a default codec
      will be attached to allow playback and recording. Valid values
      are 'duplex' (advertise a line-in and a line-out) and 'micro'
      (advertise a speaker and a microphone).
    </p>

<pre>
  ...
  &lt;devices&gt;
    &lt;sound model='ich6'&gt;
      &lt;codec type='micro'/&gt;
M
Michele Paolino 已提交
5408
    &lt;/sound&gt;
5409 5410 5411
  &lt;/devices&gt;
  ...</pre>

E
Eric Blake 已提交
5412 5413 5414
    <p>
      Each <code>sound</code> element has an optional
      sub-element <code>&lt;address&gt;</code> which can tie the
5415 5416
      device to a particular PCI
      slot, <a href="#elementsAddress">documented above</a>.
E
Eric Blake 已提交
5417 5418
    </p>

R
Richard Jones 已提交
5419 5420 5421 5422 5423 5424 5425 5426 5427 5428 5429 5430 5431 5432 5433 5434 5435 5436 5437 5438
    <h4><a name="elementsWatchdog">Watchdog device</a></h4>

    <p>
      A virtual hardware watchdog device can be added to the guest via
      the <code>watchdog</code> element.
      <span class="since">Since 0.7.3, QEMU and KVM only</span>
    </p>

    <p>
      The watchdog device requires an additional driver and management
      daemon in the guest.  Just enabling the watchdog in the libvirt
      configuration does not do anything useful on its own.
    </p>

    <p>
      Currently libvirt does not support notification when the
      watchdog fires.  This feature is planned for a future version of
      libvirt.
    </p>

5439 5440 5441 5442 5443 5444
<pre>
  ...
  &lt;devices&gt;
    &lt;watchdog model='i6300esb'/&gt;
  &lt;/devices&gt;
  ...</pre>
R
Richard Jones 已提交
5445

5446 5447 5448 5449 5450 5451
<pre>
  ...
  &lt;devices&gt;
    &lt;watchdog model='i6300esb' action='poweroff'/&gt;
  &lt;/devices&gt;
&lt;/domain&gt;</pre>
R
Richard Jones 已提交
5452 5453 5454 5455

    <dl>
      <dt><code>model</code></dt>
      <dd>
M
Matthew Booth 已提交
5456
        <p>
R
Richard Jones 已提交
5457
        The required <code>model</code> attribute specifies what real
M
Matthew Booth 已提交
5458 5459 5460 5461 5462 5463 5464 5465 5466 5467 5468
        watchdog device is emulated.  Valid values are specific to the
        underlying hypervisor.
        </p>
        <p>
        QEMU and KVM support:
        </p>
        <ul>
          <li> 'i6300esb' &mdash; the recommended device,
            emulating a PCI Intel 6300ESB </li>
          <li> 'ib700' &mdash; emulating an ISA iBase IB700 </li>
        </ul>
R
Richard Jones 已提交
5469 5470 5471
      </dd>
      <dt><code>action</code></dt>
      <dd>
M
Matthew Booth 已提交
5472
        <p>
R
Richard Jones 已提交
5473
        The optional <code>action</code> attribute describes what
M
Matthew Booth 已提交
5474 5475 5476 5477 5478 5479 5480 5481 5482 5483 5484 5485 5486
        action to take when the watchdog expires.  Valid values are
        specific to the underlying hypervisor.
        </p>
        <p>
        QEMU and KVM support:
        </p>
        <ul>
          <li>'reset' &mdash; default, forcefully reset the guest</li>
          <li>'shutdown' &mdash; gracefully shutdown the guest
            (not recommended) </li>
          <li>'poweroff' &mdash; forcefully power off the guest</li>
          <li>'pause' &mdash; pause the guest</li>
          <li>'none' &mdash; do nothing</li>
5487 5488
          <li>'dump' &mdash; automatically dump the guest
            <span class="since">Since 0.8.7</span></li>
M
Matthew Booth 已提交
5489 5490
        </ul>
        <p>
5491
        Note 1: the 'shutdown' action requires that the guest
M
Matthew Booth 已提交
5492 5493 5494 5495 5496
        is responsive to ACPI signals.  In the sort of situations
        where the watchdog has expired, guests are usually unable
        to respond to ACPI signals.  Therefore using 'shutdown'
        is not recommended.
        </p>
5497 5498 5499 5500
        <p>
        Note 2: the directory to save dump files can be configured
        by <code>auto_dump_path</code> in file /etc/libvirt/qemu.conf.
        </p>
R
Richard Jones 已提交
5501 5502 5503
      </dd>
    </dl>

5504 5505 5506 5507 5508 5509 5510 5511 5512
    <h4><a name="elementsMemBalloon">Memory balloon device</a></h4>

    <p>
      A virtual memory balloon device is added to all Xen and KVM/QEMU
      guests. It will be seen as <code>memballoon</code> element.
      It will be automatically added when appropriate, so there is no
      need to explicitly add this element in the guest XML unless a
      specific PCI slot needs to be assigned.
      <span class="since">Since 0.8.3, Xen, QEMU and KVM only</span>
5513 5514 5515
      Additionally, <span class="since">since 0.8.4</span>, if the
      memballoon device needs to be explicitly disabled,
      <code>model='none'</code> may be used.
5516 5517 5518
    </p>

    <p>
J
Ján Tomko 已提交
5519
      Example: automatically added device with KVM
5520 5521 5522 5523 5524 5525 5526 5527 5528
    </p>
<pre>
  ...
  &lt;devices&gt;
    &lt;memballoon model='virtio'/&gt;
  &lt;/devices&gt;
  ...</pre>

    <p>
J
Ján Tomko 已提交
5529
      Example: manually added device with static PCI slot 2 requested
5530 5531 5532 5533
    </p>
<pre>
  ...
  &lt;devices&gt;
J
Ján Tomko 已提交
5534 5535
    &lt;memballoon model='virtio'&gt;
      &lt;address type='pci' domain='0x0000' bus='0x00' slot='0x02' function='0x0'/&gt;
5536
      &lt;stats period='10'/&gt;
J
Ján Tomko 已提交
5537
    &lt;/memballoon&gt;
5538 5539 5540 5541 5542 5543 5544 5545
  &lt;/devices&gt;
&lt;/domain&gt;</pre>

    <dl>
      <dt><code>model</code></dt>
      <dd>
        <p>
          The required <code>model</code> attribute specifies what type
E
Eric Blake 已提交
5546 5547
          of balloon device is provided. Valid values are specific to
          the virtualization platform
5548 5549 5550 5551 5552 5553
        </p>
        <ul>
          <li>'virtio' &mdash; default with QEMU/KVM</li>
          <li>'xen' &mdash; default with Xen</li>
        </ul>
      </dd>
5554 5555 5556 5557 5558
      <dt><code>period</code></dt>
      <dd>
        <p>
          The optional <code>period</code> allows the QEMU virtio memory
          balloon driver to provide statistics through the <code>virsh
5559 5560 5561 5562 5563 5564 5565 5566 5567 5568
          dommemstat [domain]</code> command. By default, collection is
          not enabled. In order to enable, use the <code>virsh dommemstat
          [domain] --period [number]</code> command or <code>virsh edit</code>
          command to add the option to the XML definition.
          The <code>virsh dommemstat</code> will accept the options
          <code>--live</code>, <code>--current</code>, or <code>--config</code>.
          If an option is not provided, the change for a running domain will
          only be made to the active guest.
          If the QEMU driver is not at the right
          revision, the attempt to set the period will fail.
5569 5570 5571
          <span class='since'>Since 1.1.1, requires QEMU 1.5</span>
        </p>
      </dd>
5572
    </dl>
5573 5574 5575 5576 5577 5578 5579 5580 5581 5582 5583 5584 5585 5586 5587
    <h4><a name="elementsRng">Random number generator device</a></h4>

    <p>
      The virtual random number generator device allows the host to pass
      through entropy to guest operating systems.
      <span class="since">Since 1.0.3</span>
    </p>

    <p>
      Example: usage of the RNG device:
    </p>
<pre>
  ...
  &lt;devices&gt;
    &lt;rng model='virtio'&gt;
5588
      &lt;rate period="2000" bytes="1234"/&gt;
5589 5590 5591
      &lt;backend model='random'&gt;/dev/random&lt;/backend&gt;
      &lt;!-- OR --&gt;
      &lt;backend model='egd' type='udp'&gt;
5592 5593
        &lt;source mode='bind' service='1234'/&gt;
        &lt;source mode='connect' host='1.2.3.4' service='1234'/&gt;
5594 5595 5596 5597 5598 5599 5600 5601 5602 5603 5604 5605 5606 5607 5608 5609 5610
      &lt;/backend&gt;
    &lt;/rng&gt;
  &lt;/devices&gt;
  ...
</pre>
    <dl>
      <dt><code>model</code></dt>
      <dd>
        <p>
          The required <code>model</code> attribute specifies what type
          of RNG device is provided. Valid values are specific to
          the virtualization platform:
        </p>
        <ul>
          <li>'virtio' &mdash; supported by qemu and virtio-rng kernel module</li>
        </ul>
      </dd>
5611 5612 5613 5614 5615 5616 5617 5618 5619 5620 5621 5622
      <dt><code>rate</code></dt>
      <dd>
        <p>
          The optional <code>rate</code> element allows limiting the rate at
          which entropy can be consumed from the source.  The mandatory
          attribute <code>bytes</code> specifies how many bytes are permitted
          to be consumed per period.  An optional <code>period</code> attribute
          specifies the duration of a period in milliseconds; if omitted, the
          period is taken as 1000 milliseconds (1 second).
          <span class='since'>Since 1.0.4</span>
        </p>
      </dd>
5623 5624 5625 5626 5627 5628 5629 5630
      <dt><code>backend</code></dt>
      <dd>
        <p>
          The <code>backend</code> element specifies the source of entropy
          to be used for the domain. The source model is configured using the
          <code>model</code> attribute. Supported source models are:
        </p>
        <ul>
5631 5632
          <li>'random' &mdash; /dev/random (default) or /dev/hwrng
            device as source (for now, no other sources are permitted)</li>
5633 5634 5635
          <li>'egd' &mdash; a EGD protocol backend</li>
        </ul>
      </dd>
5636
      <dt><code>backend model='random'</code></dt>
5637 5638 5639
      <dd>
        <p>
          This backend type expects a non-blocking character device as input.
5640
          The only accepted paths are /dev/random and /dev/hwrng. The file
5641 5642 5643 5644
          name is specified as contents of the <code>backend</code> element.
          When no file name is specified the hypervisor default is used.
        </p>
      </dd>
5645
      <dt><code>backend model='egd'</code></dt>
5646 5647 5648 5649 5650 5651 5652 5653 5654 5655
      <dd>
        <p>
          This backend connects to a source using the EGD protocol.
          The source is specified as a character device. Refer to
          <a href='#elementsCharHostInterface'>character device host interface</a>
          for more information.
        </p>
      </dd>

    </dl>
5656

5657 5658 5659 5660 5661 5662 5663 5664
    <h4><a name="elementsTpm">TPM device</a></h4>

    <p>
      The TPM device enables a QEMU guest to have access to TPM
      functionality.
    </p>
    <p>
      The TPM passthrough device type provides access to the host's TPM
5665
      for one QEMU guest. No other software may be using the TPM device,
5666 5667 5668 5669 5670 5671 5672 5673 5674 5675 5676 5677
      typically /dev/tpm0, at the time the QEMU guest is started.
      <span class="since">'passthrough' since 1.0.5</span>
    </p>

    <p>
     Example: usage of the TPM passthrough device
    </p>
<pre>
  ...
  &lt;devices&gt;
    &lt;tpm model='tpm-tis'&gt;
      &lt;backend type='passthrough'&gt;
S
Stefan Berger 已提交
5678
        &lt;device path='/dev/tpm0'/&gt;
5679 5680 5681 5682 5683 5684 5685 5686 5687 5688 5689 5690 5691 5692 5693 5694 5695 5696 5697 5698 5699
      &lt;/backend&gt;
    &lt;/tpm&gt;
  &lt;/devices&gt;
  ...
</pre>
    <dl>
      <dt><code>model</code></dt>
      <dd>
        <p>
          The <code>model</code> attribute specifies what device
          model QEMU provides to the guest. If no model name is provided,
          <code>tpm-tis</code> will automatically be chosen.
        </p>
      </dd>
      <dt><code>backend</code></dt>
      <dd>
        <p>
          The <code>backend</code> element specifies the type of
          TPM device. The following types are supported:
        </p>
        <ul>
5700
          <li>'passthrough' &mdash; use the host's TPM device.</li>
5701 5702 5703 5704 5705 5706 5707 5708 5709 5710 5711 5712 5713 5714
        </ul>
      </dd>
      <dt><code>backend type='passthrough'</code></dt>
      <dd>
        <p>
          This backend type requires exclusive access to a TPM device on
          the host.
          An example for such a device is /dev/tpm0. The filename is
          specified as path attribute of the <code>source</code> element.
          If no file name is specified then /dev/tpm0 is automatically used.
        </p>
      </dd>
    </dl>

L
Li Zhang 已提交
5715 5716 5717 5718 5719 5720 5721 5722 5723 5724 5725 5726 5727 5728 5729 5730 5731 5732 5733 5734 5735 5736 5737 5738 5739 5740 5741 5742 5743 5744 5745 5746 5747 5748
    <h4><a name="elementsNVRAM">NVRAM device</a></h4>
    <p>
      nvram device is always added to pSeries guest on PPC64, and its address
      is allowed to be changed.  Element <code>nvram</code> (only valid for
      pSeries guest, <span class="since">since 1.0.5</span>) is provided to
      enable the address setting.
    </p>
    <p>
      Example: usage of NVRAM configuration
    </p>
<pre>
  ...
  &lt;devices&gt;
    &lt;nvram&gt;
      &lt;address type='spapr-vio' reg='0x3000'/&gt;
    &lt;/nvram&gt;
  &lt;/devices&gt;
  ...
</pre>
  <dl>
    <dt><code>spapr-vio</code></dt>
    <dd>
      <p>
        VIO device address type, only valid for PPC64.
      </p>
    </dd>
    <dt><code>reg</code></dt>
    <dd>
      <p>
        Device address
      </p>
    </dd>
  </dl>

H
Hu Tao 已提交
5749 5750 5751 5752 5753 5754 5755 5756 5757 5758 5759 5760 5761 5762 5763 5764 5765 5766 5767 5768 5769 5770 5771 5772 5773 5774 5775 5776
    <h4><a name="elementsPanic">panic device</a></h4>
    <p>
      panic device enables libvirt to receive panic notification from a QEMU
      guest.
      <span class="since">Since 1.2.1, QEMU and KVM only</span>
    </p>
    <p>
      Example: usage of panic configuration
    </p>
<pre>
  ...
  &lt;devices&gt;
    &lt;panic&gt;
      &lt;address type='isa' iobase='0x505'/&gt;
    &lt;/panic&gt;
  &lt;/devices&gt;
  ...
</pre>
  <dl>
    <dt><code>address</code></dt>
    <dd>
      <p>
        address of panic. The default ioport is 0x505. Most users
        don't need to specify an address.
      </p>
    </dd>
  </dl>

5777 5778 5779 5780 5781
  <h4><a name="elementsShmem">Shared memory device</a></h4>

    <p>
      A shared memory device allows to share a memory region between
      different virtual machines and the host.
M
Martin Kletzander 已提交
5782
      <span class="since">Since 1.2.10, QEMU and KVM only</span>
5783 5784 5785 5786 5787 5788 5789 5790 5791 5792 5793 5794 5795 5796 5797 5798 5799 5800 5801 5802 5803 5804 5805 5806 5807 5808 5809 5810 5811 5812 5813 5814 5815 5816 5817 5818 5819 5820 5821 5822 5823 5824 5825 5826 5827 5828
    </p>

<pre>
  ...
  &lt;devices&gt;
    &lt;shmem name='my_shmem0'&gt;
      &lt;size unit='M'&gt;4&lt;/size&gt;
    &lt;/shmem&gt;
    &lt;shmem name='shmem_server'&gt;
      &lt;size unit='M'&gt;2&lt;/size&gt;
      &lt;server path='/tmp/socket-shmem'/&gt;
      &lt;msi vectors='32' ioeventfd='on'/&gt;
    &lt;/shmem&gt;
  &lt;/devices&gt;
  ...
</pre>

  <dl>
    <dt><code>shmem</code></dt>
    <dd>
      The <code>shmem</code> element has one mandatory attribute,
      <code>name</code> to identify the shared memory.
    </dd>
    <dt><code>size</code></dt>
    <dd>
      The optional <code>size</code> element specifies the size of the shared
      memory. This must be power of 2 and greater than or equal to 1 MiB.
    </dd>
    <dt><code>server</code></dt>
    <dd>
      The optional <code>server</code> element can be used to configure a server
      socket the device is supposed to connect to.  The optional
      <code>path</code> attribute specifies the path to the unix socket and
      defaults to <code>/var/lib/libvirt/shmem/$shmem-$name-sock</code>.
    </dd>
    <dt><code>msi</code></dt>
    <dd>
      The optional <code>msi</code> element enables/disables (values "on"/"off",
      respectively) MSI interrupts. This option can currently be used only
      together with the <code>server</code> element. The <code>vectors</code>
      attribute can be used to specify the number of interrupt
      vectors. The <code>ioeventd</code> attribute enables/disables (values
      "on"/"off", respectively) ioeventfd.
    </dd>
  </dl>

5829 5830 5831 5832
    <h3><a name="seclabel">Security label</a></h3>

    <p>
      The <code>seclabel</code> element allows control over the
5833 5834 5835 5836 5837
      operation of the security drivers. There are three basic
      modes of operation, 'dynamic' where libvirt automatically
      generates a unique security label, 'static' where the
      application/administrator chooses the labels, or 'none'
      where confinement is disabled. With dynamic
5838 5839 5840 5841 5842
      label generation, libvirt will always automatically
      relabel any resources associated with the virtual machine.
      With static label assignment, by default, the administrator
      or application must ensure labels are set correctly on any
      resources, however, automatic relabeling can be enabled
5843 5844
      if desired.  <span class="since">'dynamic' since 0.6.1, 'static'
      since 0.6.2, and 'none' since 0.9.10.</span>
5845 5846
    </p>

5847 5848 5849 5850 5851 5852 5853
    <p>
      If more than one security driver is used by libvirt, multiple
      <code>seclabel</code> tags can be used, one for each driver and
      the security driver referenced by each tag can be defined using
      the attribute <code>model</code>
    </p>

5854
    <p>
5855
      Valid input XML configurations for the top-level security label
5856 5857 5858 5859 5860 5861 5862 5863 5864 5865 5866 5867 5868 5869 5870 5871 5872
      are:
    </p>

    <pre>
  &lt;seclabel type='dynamic' model='selinux'/&gt;

  &lt;seclabel type='dynamic' model='selinux'&gt;
    &lt;baselabel&gt;system_u:system_r:my_svirt_t:s0&lt;/baselabel&gt;
  &lt;/seclabel&gt;

  &lt;seclabel type='static' model='selinux' relabel='no'&gt;
    &lt;label&gt;system_u:system_r:svirt_t:s0:c392,c662&lt;/label&gt;
  &lt;/seclabel&gt;

  &lt;seclabel type='static' model='selinux' relabel='yes'&gt;
    &lt;label&gt;system_u:system_r:svirt_t:s0:c392,c662&lt;/label&gt;
  &lt;/seclabel&gt;
5873 5874

  &lt;seclabel type='none'/&gt;
5875 5876
    </pre>

5877 5878 5879 5880 5881 5882 5883
    <p>
      If no 'type' attribute is provided in the input XML, then
      the security driver default setting will be used, which
      may be either 'none' or 'dynamic'. If a 'baselabel' is set
      but no 'type' is set, then the type is presumed to be 'dynamic'
    </p>

5884 5885 5886 5887 5888 5889 5890 5891 5892
    <p>
      When viewing the XML for a running guest with automatic
      resource relabeling active, an additional XML element,
      <code>imagelabel</code>, will be included. This is an
      output-only element, so will be ignored in user supplied
      XML documents
    </p>
    <dl>
      <dt><code>type</code></dt>
5893 5894 5895
      <dd>Either <code>static</code>, <code>dynamic</code> or <code>none</code>
        to determine whether libvirt automatically generates a unique security
        label or not.
5896 5897 5898 5899 5900 5901 5902 5903 5904 5905 5906 5907 5908
      </dd>
      <dt><code>model</code></dt>
      <dd>A valid security model name, matching the currently
        activated security model
      </dd>
      <dt><code>relabel</code></dt>
      <dd>Either <code>yes</code> or <code>no</code>. This must always
        be <code>yes</code> if dynamic label assignment is used. With
        static label assignment it will default to <code>no</code>.
      </dd>
      <dt><code>label</code></dt>
      <dd>If static labelling is used, this must specify the full
        security label to assign to the virtual domain. The format
5909 5910 5911 5912 5913 5914 5915 5916 5917 5918 5919
        of the content depends on the security driver in use:
        <ul>
          <li>SELinux: a SELinux context.</li>
          <li>AppArmor: an AppArmor profile.</li>
          <li>
            DAC: owner and group separated by colon. They can be
            defined both as user/group names or uid/gid. The driver will first
            try to parse these values as names, but a leading plus sign can
            used to force the driver to parse them as uid or gid.
          </li>
        </ul>
5920 5921 5922
      </dd>
      <dt><code>baselabel</code></dt>
      <dd>If dynamic labelling is used, this can optionally be
5923 5924 5925 5926 5927 5928 5929 5930 5931 5932
        used to specify the base security label that will be used to generate
        the actual label. The format of the content depends on the security
        driver in use.

        The SELinux driver uses only the <code>type</code> field of the
        baselabel in the generated label. Other fields are inherited from
        the parent process when using SELinux baselabels.

        (The example above demonstrates the use of <code>my_svirt_t</code>
        as the value for the <code>type</code> field.)
5933 5934 5935 5936 5937 5938 5939 5940
      </dd>
      <dt><code>imagelabel</code></dt>
      <dd>This is an output only element, which shows the
        security label used on resources associated with the virtual domain.
        The format of the content depends on the security driver in use
      </dd>
    </dl>

5941 5942 5943 5944 5945 5946 5947 5948 5949 5950
    <p>When relabeling is in effect, it is also possible to fine-tune
      the labeling done for specific source file names, by either
      disabling the labeling (useful if the file lives on NFS or other
      file system that lacks security labeling) or requesting an
      alternate label (useful when a management application creates a
      special label to allow sharing of some, but not all, resources
      between domains), <span class="since">since 0.9.9</span>.  When
      a <code>seclabel</code> element is attached to a specific path
      rather than the top-level domain assignment, only the
      attribute <code>relabel</code> or the
5951 5952 5953 5954 5955
      sub-element <code>label</code> are supported.  Additionally,
      <span class="since">since 1.1.2</span>, an output-only
      element <code>labelskip</code> will be present for active
      domains on disks where labeling was skipped due to the image
      being on a file system that lacks security labeling.
5956 5957
    </p>

D
Daniel P. Berrange 已提交
5958
    <h2><a name="examples">Example configs</a></h2>
5959 5960 5961 5962 5963 5964 5965 5966 5967 5968 5969 5970

    <p>
      Example configurations for each driver are provide on the
      driver specific pages listed below
    </p>

    <ul>
      <li><a href="drvxen.html#xmlconfig">Xen examples</a></li>
      <li><a href="drvqemu.html#xmlconfig">QEMU/KVM examples</a></li>
    </ul>
  </body>
</html>