1. 27 10月, 2008 1 次提交
    • J
      hwmon: (lm90) Fix handling of hysteresis value · ec38fa2b
      Jean Delvare 提交于
      There are several problems in the way the hysteresis value is handled
      by the lm90 driver:
      
      * In show_temphyst(), specific handling of the MAX6646 is missing, so
        the hysteresis is reported incorrectly if the critical temperature
        is over 127 degrees C.
      * In set_temphyst(), the new hysteresis register value is written to
        the chip but data->temp_hyst isn't updated accordingly, so there is
        a short period of time (up to 2 seconds) where the old hystereris
        value will be returned while the new one is already active.
      * In set_temphyst(), the critical temperature which is used as a base
        to compute the value of the hysteresis register lacks
        device-specific handling. As a result, the value of the hysteresis
        register might be incorrect for the ADT7461 and MAX6646 chips.
      
      Fix these 3 bugs.
      Signed-off-by: NJean Delvare <khali@linux-fr.org>
      Cc: Ben Hutchings <bhutchings@solarflare.com>
      Cc: Nate Case <ncase@xes-inc.com>
      ec38fa2b