- 28 7月, 2011 6 次提交
-
-
由 Mark Brown 提交于
Rather than using the maximum voltage we get passed to select the DVS voltage to use remember the highest voltage we've ever seen. This improves how the driver works when the consumer permits higher voltages than it will ever selects in order to support the widest possible voltage range. Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Mark Brown 提交于
If we don't have a DVS VSEL value already set when we start up then start it off with the value currently being used for ON. Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Mark Brown 提交于
If the VSEL is not in use prior to us starting up then we need to make sure we initialise the GPIO before we push the DVS control to being done by the GPIO. Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Mark Brown 提交于
Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Mark Brown 提交于
Read our initial VSEL from the correct register. Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Mark Brown 提交于
With multiple wm831x devices the device IDs used for the regulators will not always be contiguous so simply taking the modulus is not sufficient to look up the ID, we need to reverse the way the ID is generated. Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
- 22 7月, 2011 7 次提交
-
-
由 Mark Brown 提交于
We need to dereference the pointers to print their values. Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Axel Lin 提交于
Properly kfree rdev->constraints in all set_machine_constraints() error paths. Also properly kfree rdev->constraints in regulator_register() error paths. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Acked-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Mark Brown 提交于
Prevent some head scratching by making the core log about some rare but possible errors with invalid voltage ranges and modes being set. Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Axel Lin 提交于
For tps65910, the number of regulator is 13. ( ARRAY_SIZE(tps65910_regs) is 13) For tps65911, the number of regulator is 12. ( ARRAY_SIZE(tps65911_regs) is 12) If we are using this driver for tps65911, we hit array access out of bounds bug in tps65910_probe() because current implementation always assume the number of regulator is 13 and thus it will access tps65911_regs[12]. Fix it by setting correct num_regulators for both chips in tps65910_probe(), and allocated neccessay memory accordingly. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Acked-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Axel Lin 提交于
Also add a default case in tps65910_list_voltage_dcdc to silence 'volt' may be used uninitialized in this function warning. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Acked-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Axel Lin 提交于
Fix a memory leak if chip id is not matched. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Acked-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Ambresh K 提交于
RES_ID is only used in 4030, to send PBM singular message to control the state of dedicated resources. In 6030, we don't have concept of PBM, hence removing the definition of RES_ID (num) from macros. Signed-off-by: NAmbresh K <ambresh@ti.com> Acked-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
- 05 7月, 2011 1 次提交
-
-
由 Mark Brown 提交于
Report the requested load and voltage for each consumer in debugfs when it is enabled. Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
- 10 6月, 2011 4 次提交
-
-
由 Mark Brown 提交于
No actual users but provide the macro so there's less surprise when it's not there. Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Mark Brown 提交于
Currently the regulator supply implementation is somewhat complex and fragile as it doesn't look like standard consumers but is instead a parallel implementation. This causes issues with locking and reference counting. Move the implementation over to using standard consumers to address this. Rather than only notifying the supply on the first enable/disable we do so every time the regulator is enabled or disabled, simplifying locking as we don't need to hold a lock on the consumer we are about to enable. Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Mark Brown 提交于
We may have multiple devices requesting a supply with the same name so include the device name in the generated filename for microamps_requested to avoid duplicate files. Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Mark Brown 提交于
With verbose filenames we can easily hit 32 characters. Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
- 09 6月, 2011 1 次提交
-
-
由 Mark Brown 提交于
Recent changes in the driver core appear to mean that the data structures for the driver core are not fully initialised unless the driver is bound. Make sure the driver core knows the dummy driver is in use by binding it to a driver. Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
- 30 5月, 2011 3 次提交
-
-
由 Colin Cross 提交于
The n_voltages initializer for the TWL6030_ADJUSTABLE_LDO macro is off by one, causing the the highest supported voltage to be unreachable. Setting the machine constraints to only allow the highest voltage causes errors: machine_constraints_voltage: VAUX3_6030: unsupportable voltage constraints twl_reg twl_reg.39: can't register VAUX3_6030, -22 twl_reg: probe of twl_reg.39 failed with error -22 This patch fixes the off by one error. Tested by setting VAUX3_6030 to 3.3V. Signed-off-by: NColin Cross <ccross@android.com> Acked-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Mark Brown 提交于
The WM8994 regulator driver is perfectly happy if the GPIO used to enable the regulator sleeps so call the appropriate GPIO API. Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Mark Brown 提交于
In order to reduce the impact of ramp times rather than enabling the regulators for a device in series use async tasks to run the actual enables. This means that the delays which the enables implement can all run in parallel, though it does mean that the order in which the supplies come on may be unstable. For super bonus fun points if any of the regulators are shared between multiple supplies on the same device (as is rather likely) then this will test our locking. Note that in this case we only delay once for each physical regulator so the threads shouldn't block each other while delaying. It'd be even nicer if we could coalesce writes to a shared enable registers in PMICs but that's definitely future work, and it may also be useful and is certainly more achievable to optimise out the parallelism if none of the regulators implement ramp delays. Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
- 27 5月, 2011 18 次提交
-
-
由 Axel Lin 提交于
In the case of get_voltage callback is NULL, current implementation in _regulator_get_voltage will return -EINVAL. Also returns proper error if ret is negative value. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Acked-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Graeme Gregory 提交于
Adding support for the twl6025. Major difference in the twl6025 is the group functionality has been removed from the chip so this affects how regulators are enabled and disabled. The names of the regulators also changed. The DCDCs of the 6025 are software controllable as well. Since V1 Use the features variable passed via platform data instead of calling global function. Change the very switch like if statements to be a more readable switch statement. Since V2 twl6025 doesn't use remap so remove it from the macros. Since V3 enable/disable functions for 4030/6030 were seperated upstream so rebase on top of this. Change DCDC reference to SMPS as this is used in TRM. Change list_voltage slightly to have less code. Signed-off-by: NGraeme Gregory <gg@slimlogic.co.uk> Acked-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Balaji T K 提交于
TWL6030: regulator is disabled via VREG_STATE TWL4030: regulator is disabled via VREG_GRP Since there is nothing common, split twlreg_enable similar to other regulator_ops Signed-off-by: NBalaji T K <balajitk@ti.com> Acked-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Balaji T K 提交于
TWL6030: regulator is enabled via VREG_STATE TWL4030: regulator is enabled via VREG_GRP Since there is nothing common, split twlreg_enable similar to other regulator_ops Signed-off-by: NBalaji T K <balajitk@ti.com> Acked-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Jorge Eduardo Candelaria 提交于
The tps65911 chip introduces new features, including changes in the regulator module. - VDD1 and VDD2 remain unchanged. - VDD3 is now named VDDCTRL and has a wider voltage range. - LDOs are now named LDO1...8 and voltage ranges are sequential, making LDOs easier to handle. Signed-off-by: NJorge Eduardo Candelaria <jedu@slimlogic.co.uk> Acked-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Axel Lin 提交于
We use val as array index, thus the valid value rangae for val should be 0 .. n_voltages-1. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Acked-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Fabio Estevam 提交于
Voltage values should be expressed in microvolts, not in milivolts. Signed-off-by: NFabio Estevam <fabio.estevam@freescale.com> Signed-off-by: NRanjani Vaidyanathan <ra5478@freescale.com> Acked-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Axel Lin 提交于
In current implementation, the original macro implementation assumes the caller pass the parameter starting from 1 (to match the register names in datasheet). Thus we have unneeded plus one then minus one operations when using MAX8997_REG_BUCK1DVS/MAX8997_REG_BUCK2DVS/MAX8997_REG_BUCK5DVS macros. This patch removes these macros to avoid unneeded plus one then minus one operations without reducing readability. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Acked-by: NKyungmin Park <kyungmin.park@samsung.com> Acked-by: NMyungJoo Ham <myungjoo.ham@samsung.com> Acked-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Mark Brown 提交于
When applying the set_voltage() requests from consumers skip over those consumers that haven't set anything, otherwise we'll come out with a maximum voltage of zero. Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Mark Brown 提交于
If either a regulator driver can't tell us what the optimum mode is (or doesn't have modes in the first place) or the system doesn't allow DRMS changes then it's more helpful for users to just say that we're in the optimal mode, even if it's from a selection of one. Still report errors if the process of picking and setting a mode changes as this may indicate that we're stuck in a low power mode and unable to deliver a higher current that the consumer just asked for. Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Jonghwan Choi 提交于
fix unreachable code. Signed-off-by: NJonghwan Choi <jhbird.choi@samsung.com> Signed-off-by: NMyungJoo Ham <myungjoo.ham@samsung.com> Acked-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Acked-by: NKyungmin Park <kyungmin.park@samsung.com> Acked-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Axel Lin 提交于
The desc_id variable should not be a static variable. The rest of the code assumes the desc_id must less than TPSxxxxx_NUM_REGULATOR. If we set desc_id to be a static variable, checking the return value of rdev_get_id() may return error. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Cc: Anuj Aggarwal <anuj.aggarwal@ti.com> Cc: Graeme Gregory <gg@slimlogic.co.uk> Acked-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Axel Lin 提交于
I check this patch again and found this actually is not a bug because MC13xxx_DEFINE explictly defines the order of each entry in the array. Thus revert the patch. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Acked-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Mark Brown 提交于
These became unused with the IRQ removal patch, I'm fairly sure that a patch was sent earlier by someone else but it doesn't seem to have been applied and I don't have a copy sitting around any more. Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Graeme Gregory 提交于
The regulator module consists of 3 DCDCs and 8 LDOs. The output voltages are configurable and are meant to supply power to the main processor and other components Signed-off-by: NGraeme Gregory <gg@slimlogic.co.uk> Signed-off-by: NJorge Eduardo Candelaria <jedu@slimlogic.co.uk> Acked-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Axel Lin 提交于
Currently, we call mc13xxx_reg_read and mc13xxx_reg_rmw for the same register. This can be converted to simply a mc13xxx_reg_read and a mc13xxx_reg_write, thus save a redundant register read. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Acked-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-
由 Mark Brown 提交于
Some systems, particularly physically large systems used for early prototyping, may experience substantial voltage drops between the regulator and the consumers as a result of long traces in the system. With these systems voltages may need to be set higher than requested in order to ensure reliable system operation. Allow systems to work around such hardware issues by allowing constraints to supply an offset to be applied to any requested and reported voltages. This is not ideal, especially since the voltage drop may be load dependant, but is sufficient for most affected systems, it is not expected to be used in production hardware. The offset is applied after all constraint processing so constraints should be specified in terms of consumer values not physically configured values. Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: NLiam Girdwood <lrg@slimlogic.co.uk>
-