1. 06 9月, 2014 1 次提交
    • S
      clocksource: sh_tmu: Document r8a7779 binding · fb0eee2f
      Simon Horman 提交于
      In general Renesas hardware is not documented to the extent
      where the relationship between IP blocks on different SoCs can be assumed
      although they may appear to operate the same way. Furthermore the
      documentation typically does not specify a version for individual
      IP blocks. For these reasons a convention of using the SoC name in place
      of a version and providing SoC-specific compat strings has been adopted.
      
      Although not universally liked this convention is used in the bindings
      for a number of drivers for Renesas hardware. The purpose of this patch is
      to update the Renesas R-Car Timer Unit (TMU) driver to follow this
      convention.
      Signed-off-by: NSimon Horman <horms+renesas@verge.net.au>
      Acked-by: NGeert Uytterhoeven <geert+renesas@glider.be>
      Acked-by: NLaurent Pinchart <laurent.pinchart@ideasonboard.com>
      
      ---
      * I plan to follow up with a patch patch to use the new binding in the
        dtsi files for the r8a7779 SoC.
      commit 471269b790aec03385dc4fb127ed7094ff83c16d
      
      v2
      * Suggestions by Mark Rutland and Sergei Shtylyov
        - Compatible strings should be "one or more" not "one" of those listed
        - Describe the generic binding as covering any MTU2 device
        - Re-order compat strings from most to least specific
      
      v3
      * Suggested by Laurent Pinchart
        - Reword in keeping with a similar though more extensive patch for CMT
      fb0eee2f