- 18 6月, 2012 19 次提交
-
-
由 Mark Brown 提交于
Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
This change makes it possible to set ramp_delay with 0.xxx mV/uS without truncation issue. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
For table based mapping, we can calculate voltage difference by below equation: abs(rdev->desc->volt_table[new_selector] - rdev->desc->volt_table[old_selector]) Thus we can make regulator_set_voltage_time_sel work for table based mapping. regulator_set_voltage_time_sel() only supports linear or table based mapping. In case it is misused, also warn if neither linear nor table based mapping is used with regulator_set_voltage_time_sel(). Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Yadwinder Singh Brar 提交于
For some hardwares ramp_delay for BUCKs is a configurable parameter which can be configured through DT or board file.This patch adds ramp_delay to regulator constraints and allow user to configure it for regulators which supports this feature, through DT or board file. It will provide two ways of setting the ramp_delay for a regulator: First, by setting it as constraints in board file(for configurable regulators) and set_machine_constraints() will take care of setting it on hardware by calling(the provided) .set_ramp_delay() operation(callback). Second, by setting it as data in regulator_desc(as fixed/default ramp_delay rate) for a regulator in driver. regulator_set_voltage_time_sel() will give preference to constraints->ramp_delay while reading ramp_delay rate for regulator. Similarly users should also take care accordingly while refering ramp_delay rate(in case of implementing their private .set_voltage_time_sel() callbacks for different regulators). [Rewrote subject for 80 columns -- broonie] Signed-off-by: NYadwinder Singh Brar <yadi.brar@samsung.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
The min_uV and max_uV are not really used in the code and misleading because the min_uV and max_uV settings does not match the value in the voltage table. For example, we have static const unsigned int ldo_vaux3_voltages[] = { 1200000, 1500000, 1800000, 2100000, 2500000, 2750000, 2790000, 2910000, }; With below min_uV/max_uV settings for AB8500_LDO_AUX3. .min_uV = 1100000, .max_uV = 3300000, The min_uV/max_uV for AB8500_LDO_AUX3 seems copy-paste from AB8500_LDO_AUX2 and is wrong. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Also removes set_voltage_time_sel callback from ab8500_regulator_fixed_ops because the voltage won't change. ( And ab8500_regulator_fixed_ops does not implement get_voltage_sel so set_voltage_time_sel won't be called ) Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
The voltage range checking should be to ensure mc13xxx_regulators[id].voltages[0] falls with min_uV and max_uV. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
For linear mappings, we can use below equation to get the voltage difference between new_selector and old_selector: abs(new_selector - old_selector) * rdev->desc->uV_step Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
For fixed voltage, the n_voltages should be 1 rather than 0. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Reuse map_voltage() to get the selector of a given uV. Then we can remove wm8350_ldo_mvolts_to_val() and wm8350_dcdc_mvolts_to_val(). Also remove unused wm8350_dcdc_val_to_mvolts() function. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Call wm8350_ldo_list_voltage() instead of open code to verify selected voltage falls within specified range. Use wm8350_ldo_list_voltage() here is less error prone. wm8350_ldo_val_to_mvolts() is only used in wm8350_ldo_list_voltage now, so remove it and move the implementation to wm8350_ldo_list_voltage(). This patch also include below small changes in wm8350_ldo_map_voltage: 1. wm8350_ldo_map_voltage() returns selector, thus rename variable mV to sel. 2. Use DIV_ROUND_UP macro to calculate selector. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
- 14 6月, 2012 3 次提交
-
-
由 Axel Lin 提交于
This patch converts .is_enabled and .get_voltage_sel to regulator_is_enabled_regmap and regulator_get_voltage_sel_regmap. For .enable, .disable, and .set_voltage_sel, the write protect level is either 1 or 2. So we cannot use regulator_[enable|disable|set_voltage_sel]_regmap. Now we store the enable reg/mask and vsel reg/mask in regulator_desc, so we can remove enable_mask, set_vout_reg, and set_vout_mask from struct tps_info. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Adjust the equation for selector >= 15 for better readability. The equation "1700000 + ((selector - 15) * 100000)" can be interpreted by: Starting from selector 15: Steps of 100mV from 1700mV Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Sangbeom Kim 提交于
To apply delay time for voltage change, replace s5m8767_set_voltage with s5m8767_set_voltage_sel. Signed-off-by: NSangbeom Kim <sbkim73@samsung.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
- 13 6月, 2012 3 次提交
-
-
由 Axel Lin 提交于
Call wm8400_ldo_list_voltage() instead of open code to verify selected voltage falls within specified range. Use wm8400_ldo_list_voltage() here is less error prone. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Sangbeom Kim 提交于
As s5m8767a is revisioned, remove unnecessary buck 2,3,4 initialization routine. Signed-off-by: NSangbeom Kim <sbkim73@samsung.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
- 11 6月, 2012 7 次提交
-
-
由 Axel Lin 提交于
rdev->desc->uV_step * abs(new_selector - old_selector) returns uV. The unit of ramp_delay is mV/us. Current code multiples 1000 at wrong place. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
rdev->desc->uV_step * abs(new_selector - old_selector) returns uV. The unit of ramp_rate is mV/us. Thus 1000 should be multiplied. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Reviewed-by: NYadwinder Singh Brar <yadi.brar@samsung.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Yadwinder Singh Brar 提交于
This patch adds regulator_set_voltage_time_sel(), to move into core, the commonly used code by drivers to provide the .set_voltage_time_sel callback. It will also allow us to configure different ramp delay for different regulators easily. Signed-off-by: NYadwinder Singh Brar <yadi.brar@samsung.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
If this driver only works when pdata->num_regulators == MAX77686_REGULATORS, let's check it earlier. Also remove unused num_regulators from struct max77686_data. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
isl_fixed_ops does not implement set_voltage_sel callback, adding map_voltage here is misleading. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
- 08 6月, 2012 8 次提交
-
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Also adds tps6586x_ldo0_voltages mapping table for LDO0, so we can remove the hack in tps6586x_list_voltage() and convert it to regulator_list_voltage_table. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
It's a little bit hard to read that the "else" case means id == PALMAS_REG_SMPS10. if (id != PALMAS_REG_SMPS10){ do something for the cases id != PALMAS_REG_SMPS10; } else { do something for the case id == PALMAS_REG_SMPS10; } This patch changes above syntax to switch statement. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Acked-by: NGraeme Gregory <gg@slimlogic.co.uk> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Current code actually clears more bits than PALMAS_SMPS12_CTRL_MODE_ACTIVE_MASK bits. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Acked-by: NGraeme Gregory <gg@slimlogic.co.uk> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
For linear mappings, we can use below equation to get the voltage difference between new_selector and old_selector: abs(new_selector - old_selector) * rdev->desc->uV_step Signed-off-by: NAxel Lin <axel.lin@gmail.com> Acked-by: NLaxman Dewangan <ldewangan@nvidia.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
For fixed voltage, DA9030_LDO13 and DA9034_LDO5, the info->vol_reg is DA9030_INVAL/DA9034_INVAL. It does not make sense to read/write to DA9030_INVAL/DA9034_INVAL address. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-