      net: dsa: lan9303: Do not disable switch fabric port 0 at .probe · 3c91b0c1
      Egil Hjelmeland 提交于
      Make the LAN9303 work when lan9303_probe() is called twice.
      
      For some unknown reason the LAN9303 switch fail to forward data when switch
      fabric port 0 TX is disabled during probe. (Write of LAN9303_MAC_TX_CFG_0
      in lan9303_disable_processing_port().)
      
      In that situation the switch fabric seem to receive frames, because the ALR
      is learning addresses. But no frames are transmitted on any of the ports.
      
      In our system lan9303_probe() is called twice, first time
      dsa_register_switch() return -EPROBE_DEFER. As an experiment, modified the
      code to skip writing LAN9303_MAC_TX_CFG_0, port 0 during the first probe.
      Then the switch works as expected.
      
      Resolve the problem by not calling lan9303_disable_processing_port() on
      port 0 during probe. Ports 1 and 2 are still disabled.
      
      Although unsatisfying that the exact failure mechanism is not known,
      the patch should not cause any harm.
      Signed-off-by: NEgil Hjelmeland <privat@egil-hjelmeland.no>
      Reviewed-by: NAndrew Lunn <andrew@lunn.ch>
      Signed-off-by: NDavid S. Miller <davem@davemloft.net>