- 22 3月, 2012 21 次提交
-
-
由 Alex Elder 提交于
The argument parsing routine already computes the size of the mon_addrs buffer it extracts from the "command." Pass it to the caller so it can use it to provide the length to rbd_get_client(). Signed-off-by: NAlex Elder <elder@dreamhost.com>
-
由 Alex Elder 提交于
This is a bit gratuitous, but there are a few things that can be verified at build time rather than run time, so do that. Signed-off-by: NAlex Elder <elder@dreamhost.com>
-
由 Alex Elder 提交于
Make use of a few simple helper routines to parse the arguments rather than sscanf(). This will treat both missing and too-long arguments as invalid input (rather than silently truncating the input in the too-long case). In time this can also be used by rbd_add() to use the passed-in buffer in place, rather than copying its contents into new buffers. It appears to me that the sscanf() previously used would not correctly handle a supplied snapshot--the two final "%s" conversion specifications were not separated by a space, and I'm not sure how sscanf() handles that situation. It may not be well-defined. So that may be a bug this change fixes (but I didn't verify that). The sizes of the mon_addrs and options buffers are now passed to rbd_add_parse_args(), so they can be supplied to copy_token(). Signed-off-by: NAlex Elder <elder@dreamhost.com>
-
由 Alex Elder 提交于
Move the code that parses the arguments provided to rbd_add() (which are supplied via /sys/bus/rbd/add) into a separate function. Also rename the "mon_dev_name" variable in rbd_add() to be "mon_addrs". The variable represents a list of one or more comma-separated monitor IP addresses, each with an optional port number. I think "mon_addrs" captures that notion a little better. Signed-off-by: NAlex Elder <elder@dreamhost.com>
-
由 Alex Elder 提交于
If a couple pointers are initialized to NULL then a single "out_nomem" label can be used for all of the memory allocation failure cases in rbd_add(). Also, get rid of the "irc" local variable there. There is no real need for "rc" to be type ssize_t, and it can be used in the spot "irc" was. Signed-off-by: NAlex Elder <elder@dreamhost.com> Signed-off-by: NSage Weil <sage@newdream.net>
-
由 Alex Elder 提交于
The length of the string containing the monitor address specification(s) will never exceed the length of the string passed in to rbd_add(). The same holds true for the ceph + rbd options string. So reduce the amount of memory allocated for these to that length rather than the maximum (1024 bytes). Signed-off-by: NAlex Elder <elder@dreamhost.com> Signed-off-by: NSage Weil <sage@newdream.net>
-
由 Alex Elder 提交于
Since rbd_get_client() currently returns an error code. It assigns the rbd_client field of the rbd_device structure it is passed if successful. Instead, have it return the created rbd_client structure and return a pointer-coded error if there is an error. This makes the assignment of the client pointer more obvious at the call site. Signed-off-by: NAlex Elder <elder@dreamhost.com> Signed-off-by: NSage Weil <sage@newdream.net>
-
由 Alex Elder 提交于
Here are a few very simple cleanups: - Add a "RBD_" prefix to the two driver name string definitions. - Move the definition of struct rbd_request below struct rbd_req_coll to avoid the need for an empty declaration of the latter. - Move and group the definitions of rbd_root_dev_release() and rbd_root_dev, as well as rbd_bus_type and rbd_bus_attrs[], close to the top of the file. Arrange the latter so rbd_bus_type.bus_attrs can be initialized statically. - Get rid of an unnecessary local variable in rbd_open(). - Rework some hokey logic in rbd_bus_add_dev(), so the value of "ret" at the end is either 0 or -ENOENT to avoid the need for the code duplication that was there. - Rename a goto target in rbd_add(). Signed-off-by: NAlex Elder <elder@dreamhost.com> Signed-off-by: NSage Weil <sage@newdream.net>
-
由 Alex Elder 提交于
The spinlock used to protect rbd_client_list is named "node_lock". Rename it to "rbd_client_list_lock" to make it more obvious what it's for. Signed-off-by: NAlex Elder <elder@dreamhost.com> Signed-off-by: NSage Weil <sage@newdream.net>
-
由 Alex Elder 提交于
Since rbd_client_create() is only called in one place, move the acquisition of the mutex around that call inside that function. Signed-off-by: NAlex Elder <elder@dreamhost.com> Signed-off-by: NSage Weil <sage@newdream.net>
-
由 Alex Elder 提交于
Since rbd_get_client() is only called in one place, move the acquisition of the mutex around that call inside that function. Furthermore, within rbd_get_client(), it appears the mutex only needs to be held while calling rbd_client_create(). (Moving the lock inside that function will wait for the next patch.) Signed-off-by: NAlex Elder <elder@dreamhost.com> Signed-off-by: NSage Weil <sage@newdream.net>
-
由 Alex Elder 提交于
In rbd_get_client(), if a client is reused, a number of things get done while still holding the list lock unnecessarily. This just moves a few things that need no lock protection outside the lock. Signed-off-by: NAlex Elder <elder@dreamhost.com> Signed-off-by: NSage Weil <sage@newdream.net>
-
由 Alex Elder 提交于
It used to be that selecting a new unique identifier for an added rbd device required searching all existing ones to find the highest id is used. A recent change made that unnecessary, but made it so that id's used were monotonically non-decreasing. It's a bit more pleasant to have smaller rbd id's though, and this change makes ids get allocated as they were before--each new id is one more than the maximum currently in use. Signed-off-by: NAlex Elder <elder@dreamhost.com> Signed-off-by: NSage Weil <sage@newdream.net>
-
由 Alex Elder 提交于
The only time entries are added to or removed from the global rbd_dev_list is exactly when a "put" or "get" operation is being performed on a rbd_dev's id. So just move the list management code into get/put routines. Signed-off-by: NAlex Elder <elder@dreamhost.com> Signed-off-by: NSage Weil <sage@newdream.net>
-
由 Alex Elder 提交于
The rbd_dev_list is just a simple list of all the current rbd_devices. Using the ctl_mutex as a concurrency guard is overkill. Instead, use a spinlock for that specific purpose. This also reduces the window that the ctl_mutex needs to be held in rbd_add(). Signed-off-by: NAlex Elder <elder@dreamhost.com> Signed-off-by: NSage Weil <sage@newdream.net>
-
由 Alex Elder 提交于
In order to select a new unique identifier for an added rbd device, the list of all existing ones is searched and a value one greater than the highest id is used. The list search can be avoided by using an atomic variable that keeps track of the current highest id. Using a get/put model for id's we can limit the boundless growth of id numbers a bit by arranging to reuse the current highest id once it gets released. Add these calls to "put" the id when an rbd is getting removed. Note that this changes the pattern of device id's used--new values will never be below the highest one seen so far (even if there exists an unused lower one). I assert this is OK because the key property of an rbd id is its uniqueness, not its magnitude. Regardless, a follow-on patch will restore the old way of doing things, I just think this commit just makes the incremental change to atomics a little easier to understand. Signed-off-by: NAlex Elder <elder@dreamhost.com> Signed-off-by: NSage Weil <sage@newdream.net>
-
由 Alex Elder 提交于
Move the loop that finds a new unique rbd id to use into its own helper function. Signed-off-by: NAlex Elder <elder@dreamhost.com> Signed-off-by: NSage Weil <sage@newdream.net>
-
由 Josh Durgin 提交于
There's already a constant for this anyway. Since rbd_header_set_snap() is only used to set the rbd device snap_name field, just do that within that function rather than having it take the snap_name as an argument. Signed-off-by: NAlex Elder <elder@dreamhost.com> Signed-off-by: NSage Weil <sage@newdream.net> v2: Changed interface rbd_header_set_snap() so it explicitly updates the snap_name in the rbd_device. Also added a BUILD_BUG_ON() to verify the size of the snap_name field is sufficient for SNAP_HEAD_NAME.
-
由 Alex Elder 提交于
The rbd_device structure maintains a duplicate copy of the ceph_client pointer maintained in its rbd_client structure. There appears to be no good reason for this, and its presence presents a risk of them getting out of synch or otherwise misused. So kill it off, and use the rbd_client copy only. Signed-off-by: NAlex Elder <elder@dreamhost.com> Signed-off-by: NSage Weil <sage@newdream.net>
-
由 Alex Elder 提交于
ceph_parse_options() takes the address of a pointer as an argument and uses it to return the address of an allocated structure if successful. With this interface is not evident at call sites that the pointer is always initialized. Change the interface to return the address instead (or a pointer-coded error code) to make the validity of the returned pointer obvious. Signed-off-by: NAlex Elder <elder@dreamhost.com> Signed-off-by: NSage Weil <sage@newdream.net>
-
由 Alex Elder 提交于
Some minor cleanups in "drivers/block/rbd.c: - Use the more meaningful "RBD_MAX_OBJ_NAME_LEN" in place if "96" in the definition of RBD_MAX_MD_NAME_LEN. - Use DEFINE_SPINLOCK() to define and initialize node_lock. - Drop a needless (char *) cast in parse_rbd_opts_token(). - Make a few minor formatting changes. Signed-off-by: NAlex Elder <elder@dreamhost.com> Signed-off-by: NSage Weil <sage@newdream.net>
-
- 03 2月, 2012 2 次提交
-
-
由 Alex Elder 提交于
The rbd_client structure uses a kref to arrange for cleaning up and freeing an instance when its last reference is dropped. The cleanup routine is rbd_client_release(), and one of the things it does is delete the rbd_client from rbd_client_list. It acquires node_lock to do so, but the way it is done is still not safe. The problem is that when attempting to reuse an existing rbd_client, the structure found might already be in the process of getting destroyed and cleaned up. Here's the scenario, with "CLIENT" representing an existing rbd_client that's involved in the race: Thread on CPU A | Thread on CPU B --------------- | --------------- rbd_put_client(CLIENT) | rbd_get_client() kref_put() | (acquires node_lock) kref->refcount becomes 0 | __rbd_client_find() returns CLIENT calls rbd_client_release() | kref_get(&CLIENT->kref); | (releases node_lock) (acquires node_lock) | deletes CLIENT from list | ...and starts using CLIENT... (releases node_lock) | and frees CLIENT | <-- but CLIENT gets freed here Fix this by having rbd_put_client() acquire node_lock. The result could still be improved, but at least it avoids this problem. Signed-off-by: NAlex Elder <elder@dreamhost.com> Signed-off-by: NSage Weil <sage@newdream.net>
-
由 Alex Elder 提交于
If an existing rbd client is found to be suitable for use in rbd_get_client(), the rbd_options structure is not being freed as it should. Fix that. Signed-off-by: NAlex Elder <elder@dreamhost.com> Signed-off-by: NSage Weil <sage@newdream.net>
-
- 13 1月, 2012 1 次提交
-
-
由 Alex Elder 提交于
New rbd device structures get initialized in rbd_add(). Many of the fields rely on being initially zero-filled. However we lockdep was noticing that the rw_semaphore embedded in the header field was not getting properly initialized. Fix that. Signed-off-by: NAlex Elder <elder@dreamhost.com> Signed-off-by: NSage Weil <sage@newdream.net>
-
- 08 12月, 2011 2 次提交
-
-
由 Josh Durgin 提交于
This doesn't interact with resizing well, since it doesn't set the size of the device to the size at the snapshot. It's also an expensive operation to be synchronous. Rollback can still be done with the userspace rbd tool. Signed-off-by: NJosh Durgin <josh.durgin@dreamhost.com>
-
由 Josh Durgin 提交于
This protects against opening future rbd images that have incompatible format changes. Signed-off-by: NJosh Durgin <josh.durgin@dreamhost.com>
-
- 26 10月, 2011 1 次提交
-
-
由 Sage Weil 提交于
This simplifies the init/shutdown paths, and makes client->msgr available during the rest of the setup process. Signed-off-by: NSage Weil <sage@newdream.net>
-
- 15 9月, 2011 1 次提交
-
-
由 Justin P. Mattock 提交于
This is a resend from the original, changing the title from PATCH to RFC(since this is a review for commit, and I should have put that the first go around). and also removing some of the commit's with ia64 and bash since it is significant. let me know if I might have missed anything etc.. Signed-off-by: NJustin P. Mattock <justinmattock@gmail.com> Signed-off-by: NJiri Kosina <jkosina@suse.cz>
-
- 27 7月, 2011 2 次提交
-
-
由 Josh Durgin 提交于
This improves performance since more requests can be merged. Reviewed-by: NYehuda Sadeh <yehuda@hq.newdream.net> Signed-off-by: NJosh Durgin <josh.durgin@dreamhost.com>
-
由 Yehuda Sadeh 提交于
We were missing this cleanup, so when a device was released the osd didn't clean up its watchers list, so following notifications could be slow as osd needed to timeout on the client. Signed-off-by: NYehuda Sadeh <yehuda@hq.newdream.net>
-
- 25 5月, 2011 3 次提交
-
-
由 Sage Weil 提交于
If we get a notification that the image header has changed, check for a change in the image size. Signed-off-by: NSage Weil <sage@newdream.net>
-
由 Sage Weil 提交于
Signed-off-by: NSage Weil <sage@newdream.net>
-
由 Sage Weil 提交于
Signed-off-by: NSage Weil <sage@newdream.net>
-
- 20 5月, 2011 1 次提交
-
-
由 Sage Weil 提交于
Signed-off-by: NSage Weil <sage@newdream.net>
-
- 14 5月, 2011 1 次提交
-
-
由 Yehuda Sadeh 提交于
The rbd driver currently splits bios when they span an object boundary. However, the blk_end_request expects the completions to roll up the results in block device order, and the split rbd/ceph ops can complete in any order. This patch adds a struct rbd_req_coll to track completion of split requests and ensures that the results are passed back up to the block layer in order. This fixes errors where the file system gets completion of a read operation that spans an object boundary before the data has actually arrived. The bug is easily reproduced with iozone with a working set larger than available RAM. Reported-by: NFyodor Ustinov <ufm@ufm.su> Signed-off-by: NYehuda Sadeh <yehuda@hq.newdream.net> Signed-off-by: NSage Weil <sage@newdream.net>
-
- 13 5月, 2011 1 次提交
-
-
由 Sage Weil 提交于
The ops vector must be freed by the rbd_do_request caller. Signed-off-by: NSage Weil <sage@newdream.net>
-
- 04 5月, 2011 1 次提交
-
-
由 Sage Weil 提交于
ceph_osdc_alloc_request returns NULL on failure. Signed-off-by: NSage Weil <sage@newdream.net>
-
- 23 3月, 2011 1 次提交
-
-
由 Yehuda Sadeh 提交于
Send notifications when we change the rbd header (e.g. create a snapshot) and wait for such notifications. This allows synchronizing the snapshot creation between different rbd clients/rools. Signed-off-by: NYehuda Sadeh <yehuda@hq.newdream.net> Signed-off-by: NSage Weil <sage@newdream.net>
-
- 13 1月, 2011 1 次提交
-
-
由 Yehuda Sadeh 提交于
Previously we didn't clean up the sysfs entry that was just created. Signed-off-by: NYehuda Sadeh <yehuda@hq.newdream.net> Signed-off-by: NSage Weil <sage@newdream.net>
-
- 02 12月, 2010 1 次提交
-
-
由 Yehuda Sadeh 提交于
The new interface creates directories per mapped image and under each it creates a subdir per available snapshot. This allows keeping a cleaner interface within the sysfs guidelines. The ABI documentation was updated too. Acked-by: NGreg Kroah-Hartman <gregkh@suse.de> Signed-off-by: NYehuda Sadeh <yehuda@hq.newdream.net> Signed-off-by: NSage Weil <sage@newdream.net>
-