- 16 3月, 2015 8 次提交
-
-
由 Marcel Holtmann 提交于
The OOB public and secret key pair is different from the non-OOB pairing procedure. SO when OOB method is in use, then use this key pair instead of generating a new one. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
Then the local out-of-band data for LE SC pairing is requested via Read Local OOB Extended Data command, then fill in the values generated by the smp_generate_oob function. Every call of this command will overwrite previously generated values. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
This patch adds a smp_generate_oob function that allows to create local out-of-band data that can be used for pairing and also provides the confirmation and random value. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
The security manager device will require the use of AES-CMAC hash for out-of-band data generation. This patch makes sure it is correctly set up and available. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
Every Bluetooth Low Energy controller requires a local crypto context to handle the resolvable private addresses. At the moment this is just a single crypto context, but for out-of-band data generation it will require an additional. To facility this, create a struct smp_dev that will hold all the extra information. This patch is just the refactoring in preparation for future changes. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
Within the security manager, it makes sense to use kzfree instead of kfree for all data structures. This ensures that no key material leaks by accident. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
The HCI_CONN_REMOTE_OOB connection flag is used to indicate if the pairing initiator has provided out-of-band data. However since that value is no longer used in any decision making, just remove it. It is actually unclear what purpose the OOB data present field from the HCI IO Capability Response event serves in the first place. If either side provided out-of-band data, then that data will be used for pairing. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
When only the pairing initiator is providing out-of-band data, then the receiver side was ignoring the data. For some reason the code was checking if the initiator has received out-of-band data and only then also provide the required inidication that the acceptor actually has the needed data available. For BR/EDR out-of-band pairing it is enough if one side has received out-of-band data. There are no extra checks needed here to make this work smoothly. The only thing that is needed is to tell the controller if data is present (and if it is P-192 or P-256 or both) and then let the controller actually figure out the rest. This means the check for outgoing connection or if the initiator has indicated data are completely pointless and are in fact actually causing harm. The check in question is this one: if (conn->out || test_bit(HCI_CONN_REMOTE_OOB, &conn->flags)) { After just taking the conditional check out and always executing the code for determining the type of out-of-band data, the pairing works flawlessly and prodcudes authenticated link keys. The patch itself looks more complicated due to the reformatting of the indentation, but it essentially just a two-line change. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
- 15 3月, 2015 16 次提交
-
-
由 Marcel Holtmann 提交于
This adds support for the simplest possible version of Read Local OOB Extended Data management command. It includes all mandatory fields, but none of the actual pairing related ones. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
The eir_append_data helper function is needed for generating the extended local OOB data fields. So move it up into the right location. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
This adds support for the simplest possible version of Read Advertising Features management command. It allows basic testing of the interface. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
Changes to the global configuration updates like settings, class of device, name etc. can be received by every user. They are allowed to read them in the first place so provide the updates via events as well. Otherwise untrusted users start polling for updates and that is not a desired behavior. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
Until now the management interface was restricted to CAP_NET_ADMIN. With this change every user can open the management socket. However the list of commands is heavily restricted to getting basic information about the attached controllers. No access for configuration or other operation is provided. The events are also limited. This is done so that no keys can leak or untrusted users can mess with the Bluetooth configuration. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
Check the required trust level of each management command with the trust level of the management socket. If it does not match up, then return the newly introduced permission denied error. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
The flags field for the management command table will be always initialized to zero and thus no need to do that manually. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
Some management commands are safe to be accessed from any user without special permissions. First step for allowing access to any of these commands from untrusted application is to mark them accordingly. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
The management interface will need access to the socket flags and so provide a helper function for checking them. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
With the introduction of trusted socket flag for control and monitor channels, it is now possible to use a single function for sending packets to these sockets. And with that consolidate the handling. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
Providing a global trusted flag for management control sockets provides an easy way for identifying sockets and imposing restriction on it. For now all management sockets are trusted since they require CAP_NET_ADMIN. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
The Read Extended Contoller Index List command can be used for retrieving the complete list of local available controllers. This included configured, unconfigured and also AMP controllers. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
This introduces support for using Extended Index Added and Extended Index Removed events. These events contain the controller type and also the hardware bus information from the driver. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
For sending Index Added, Index Removed, Unconfigured Index Added and Unconfigured Index Removed managment events the new helper functions allows taking into account if these events are enabled for a certain management socket or not. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
The hci_send_to_flagged_channel helper function can be used to send packets to all channels that have a certain HCI socket flag set. This is especially useful for managment events that are limited to sockets that have first enabled certain functionality. This allows for filtering of events without confusing existing users. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
To filter out certain actions for certain HCI sockets introcuce a flags field that allows to configure specific settings on individual sockets. Since the hci_pinfo structure is private in hci_sock.c, provide helper functions for setting and clearing a given flag. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
- 14 3月, 2015 2 次提交
-
-
由 Marcel Holtmann 提交于
With the extension of hdev->dev_flags utilizing a bitmap now, the space is no longer restricted. Merge the hdev->dbg_flags into hdev->dev_flags to save space on 64-bit architectures. On 32-bit architectures no size reduction happens. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
The hdev->dev_flags field has outgrown itself on 32-bit systems. So instead of hacking around it, switch to using DECLARE_BITMAP. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
- 13 3月, 2015 8 次提交
-
-
由 Marcel Holtmann 提交于
Instead of manually coding test_and_set_bit on hdev->dev_flags all the time, use hci_dev_test_and_set_flag helper macro. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
Instead of manually coding test_and_clear_bit on hdev->dev_flags all the time, use hci_dev_test_and_clear_flag helper macro. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
Instead of manually coding test_and_change_bit on hdev->dev_flags all the time, use hci_dev_test_and_change_flag helper macro. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
Instead of manually coding change_bit on hdev->dev_flags all the time, use hci_dev_change_flag helper macro. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
Instead of manually coding clear_bit on hdev->dev_flags all the time, use hci_dev_clear_flag helper macro. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
Instead of manually coding set_bit on hdev->dev_flags all the time, use hci_dev_set_flag helper macro. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
Instead of manually coding test_bit on hdev->dev_flags all the time, use hci_dev_test_flag helper macro. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
The patch adds a second advertising setting that allows switching of the controller into connectable mode independent of the global connectable setting. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
- 12 3月, 2015 1 次提交
-
-
由 Marcel Holtmann 提交于
The SMP code contains two else branches that are not needed since the successful test will actually leave the function. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
- 11 3月, 2015 5 次提交
-
-
由 Johan Hedberg 提交于
If we're given an RPA when checking whether we're paired or not, we should consult the local RPA storage whether there's a matching IRK. This we we ensure that hci_bdaddr_is_paired() gives the right result even when trying to pair a second time with the same device with an RPA. Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com> Signed-off-by: NMarcel Holtmann <marcel@holtmann.org>
-
由 Johan Hedberg 提交于
When finding a matching LTK the rcu_read_unlock() function was failing to release the RCU read lock. This patch adds the missing call to rcu_reaD_unlock(). Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com> Signed-off-by: NMarcel Holtmann <marcel@holtmann.org>
-
由 Marcel Holtmann 提交于
This patch increments the management interface revision due to introduction of new static address setting and fixes for the fast connectable feature. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Johan Hedberg 提交于
To make the behavior predictable when attempting to pair with a device for which we already have a Link Key or Long Term Key, this patch adds a new 'Already Paired' error which gets sent in such a scenario. Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com> Signed-off-by: NMarcel Holtmann <marcel@holtmann.org>
-
由 Johan Hedberg 提交于
To maximize the usability of the Fast Connectable feature we should make it possible to set (or unset) it at any given moment. This means removing the dependency on the 'connectable' setting as well as the 'powered' setting. The former makes also sense since page scan may get enabled through add_device even if 'connectable' is false. To keep the setting available over power cycles its flag also needs to be removed from the flags that are cleared upon HCI_Reset. Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com> Signed-off-by: NMarcel Holtmann <marcel@holtmann.org>
-