- 15 7月, 2011 1 次提交
-
-
由 Guenter Roeck 提交于
Coefficients to convert chip register values to voltage/current have been slightly changed in revision B of the chip datasheet. Update driver coefficients to match the coefficients in the datasheet. Signed-off-by: NGuenter Roeck <guenter.roeck@ericsson.com> Acked-by: NJean Delvare <khali@linux-fr.org>
-
- 02 7月, 2011 1 次提交
-
-
由 Guenter Roeck 提交于
Probe function did not free allocated memory if it failed. Fix it. Signed-off-by: NGuenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: NRobert Coulson <robert.coulson@ericsson.com>
-
- 19 5月, 2011 1 次提交
-
-
由 Guenter Roeck 提交于
Add support for Analog Devices ADM1275 Hot-Swap Controller and Digital Power Monitor Signed-off-by: NGuenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: NTom Grennan <tom.grennan@ericsson.com>
-