- 25 7月, 2020 1 次提交
-
-
由 Christoph Hellwig 提交于
Rework the remaining setsockopt code to pass a sockptr_t instead of a plain user pointer. This removes the last remaining set_fs(KERNEL_DS) outside of architecture specific code. Signed-off-by: NChristoph Hellwig <hch@lst.de> Acked-by: Stefan Schmidt <stefan@datenfreihafen.org> [ieee802154] Acked-by: NMatthieu Baerts <matthieu.baerts@tessares.net> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
- 21 7月, 2020 2 次提交
-
-
由 Karsten Graul 提交于
There is a current limit of 1920 registered dmb buffers per ISM device for smc-d. One link group can contain 255 connections, each connection is using one dmb buffer. When the connection is closed then the registered buffer is held in a queue and is reused by the next connection. When a link group is 'full' then another link group is created and uses an own buffer pool. The link groups are added to a list using list_add() which puts a new link group to the first position in the list. In the situation that many connections are opened (>1920) and a few of them stay open while others are closed quickly we end up with at least 8 link groups. For a new connection a matching link group is looked up, iterating over the list of link groups. The trailing 7 link groups all have registered dmb buffers which could be reused, while the first link group has only a few dmb buffers and then hit the 1920 limit. Because the first link group is not full (255 connection limit not reached) it is chosen and finally the connection falls back to TCP because there is no dmb buffer available in this link group. There are multiple ways to fix that: using list_add_tail() allows to scan older link groups first for free buffers which ensures that buffers are reused first. This fixes the problem for smc-r link groups as well. For smc-d there is an even better way to address this problem because smc-d does not have the 255 connections per link group limit. So fix the problem for smc-d by allowing large link groups. Fixes: c6ba7c9b ("net/smc: add base infrastructure for SMC-D and ISM") Reviewed-by: NUrsula Braun <ubraun@linux.ibm.com> Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
由 Karsten Graul 提交于
To get a send slot smc_wr_tx_get_free_slot() is called, which might wait for a free slot. When smc_wr_tx_get_free_slot() returns there is a check if the connection was killed in the meantime. In that case don't only return an error, but also put back the free slot. Fixes: b2900980 ("net/smc: cancel send and receive for terminated socket") Reviewed-by: NUrsula Braun <ubraun@linux.ibm.com> Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
- 20 7月, 2020 11 次提交
-
-
由 Christoph Hellwig 提交于
Just check for a NULL method instead of wiring up sock_no_{get,set}sockopt. Signed-off-by: NChristoph Hellwig <hch@lst.de> Acked-by: NMarc Kleine-Budde <mkl@pengutronix.de> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
由 Karsten Graul 提交于
When a listen socket is closed then all non-accepted sockets in its accept queue are to be released. Inside __smc_release() the helper smc_restore_fallback_changes() restores the changes done to the socket without to check if the clcsocket has a file set. This can result in a crash. Fix this by checking the file pointer first. Reviewed-by: NUrsula Braun <ubraun@linux.ibm.com> Fixes: f536dffc ("net/smc: fix closing of fallback SMC sockets") Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
由 Karsten Graul 提交于
Two buffers are allocated for each SMC connection. Each buffer is added to a buffer list after creation. When the second buffer allocation fails, the first buffer is freed but not deleted from the list. This might result in crashes when another connection picks up the freed buffer later and starts to work with it. Reviewed-by: NUrsula Braun <ubraun@linux.ibm.com> Fixes: 6511aad3 ("net/smc: change smc_buf_free function parameters") Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
由 Karsten Graul 提交于
The dma related ...sync_sg... functions check the link state before the dma function is actually called. But the check in smc_link_usable() allows links in ACTIVATING state which are not yet mapped to dma memory. Under high load it may happen that the sync_sg functions are called for such a link which results in an debug output like DMA-API: mlx5_core 0002:00:00.0: device driver tries to sync DMA memory it has not allocated [device address=0x0000000103370000] [size=65536 bytes] To fix that introduce a helper to check for the link state ACTIVE and use it where appropriate. And move the link state update to ACTIVATING to the end of smcr_link_init() when most initial setup is done. Reviewed-by: NUrsula Braun <ubraun@linux.ibm.com> Fixes: d854fcbf ("net/smc: add new link state and related helpers") Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
由 Karsten Graul 提交于
As smc client the delete link requests are assigned to the flow when _any_ flow is active. This may break other flows that do not expect delete link requests during their handling. Fix that by assigning the request only when an add link flow is active. With that fix the code for smc client and smc server is the same, so remove the separate handling. Reviewed-by: NUrsula Braun <ubraun@linux.ibm.com> Fixes: 9ec6bf19 ("net/smc: llc_del_link_work and use the LLC flow for delete link") Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
由 Karsten Graul 提交于
When a new ib device is up smc will send an add link invitation to the peer if needed. This is currently done with rudimentary flow control. Under high workload these add link invitations can disturb other llc flows because they arrive unexpected. Fix this by integrating the invitations into the normal llc event flow and handle them as a flow. While at it, check for already assigned requests in the flow before the new add link request is assigned. Reviewed-by: NUrsula Braun <ubraun@linux.ibm.com> Fixes: 1f90a05d ("net/smc: add smcr_port_add() and smcr_link_up() processing") Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
由 Karsten Graul 提交于
To be save from unexpected or late llc response messages check if the arrived message fits to the current flow type and drop out-of-flow messages. And drop it when there is already a response assigned to the flow. Reviewed-by: NUrsula Braun <ubraun@linux.ibm.com> Fixes: ef79d439 ("net/smc: process llc responses in tasklet context") Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
由 Karsten Graul 提交于
Before an smc ib device is used the first time for an smc link it is lazily initialized. When there are 2 active link groups and a new ib device is brought online then it might happen that 2 link creations run in parallel and enter smc_ib_setup_per_ibdev(). Both allocate new send and receive completion queues on the device, but only one set of them keeps assigned and the other leaks. Fix that by protecting the setup and cleanup code using a mutex. Reviewed-by: NUrsula Braun <ubraun@linux.ibm.com> Fixes: f3c1dedd ("net/smc: separate function for link initialization") Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
由 Karsten Graul 提交于
For new rdma connections the SMC server assigns the link and sends the link data in the clc accept message. To match the correct link use not only the qp_num but also the gid and the mac of the links. If there are equal qp_nums for different links the wrong link would be chosen. Reviewed-by: NUrsula Braun <ubraun@linux.ibm.com> Fixes: 0fb0b02b ("net/smc: adapt SMC client code to use the LLC flow") Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
由 Karsten Graul 提交于
In a link-down condition we notify the SMC server and expect that the server will finally trigger the link clear processing on the client side. This could fail when anything along this notification path goes wrong. Clear the link as part of SMC client link-down processing to prevent dangling links. Reviewed-by: NUrsula Braun <ubraun@linux.ibm.com> Fixes: 541afa10 ("net/smc: add smcr_port_err() and smcr_link_down() processing") Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
由 Karsten Graul 提交于
A delete link could arrive during confirm link processing. Handle this situation directly in smc_llc_srv_conf_link() rather than using the logic in smc_llc_wait() to avoid the unexpected message handling there. Reviewed-by: NUrsula Braun <ubraun@linux.ibm.com> Fixes: 1551c95b ("net/smc: final part of add link processing as SMC server") Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
- 09 7月, 2020 5 次提交
-
-
由 Ursula Braun 提交于
CLC proposal messages of future SMCD versions could be larger than SMCD V1 CLC proposal messages. To enable toleration in SMC V1 the receival of CLC proposal messages is adapted: * accept larger length values in CLC proposal * check trailing eye catcher for incoming CLC proposal with V1 length only * receive the whole CLC proposal even in cases it does not fit into the V1 buffer Fixes: e7b7a64a ("smc: support variable CLC proposal messages") Signed-off-by: NUrsula Braun <ubraun@linux.ibm.com> Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
由 Ursula Braun 提交于
The similar smc_ib_devices spinlock has been converted to a mutex. Protecting the smcd_dev_list by a mutex is possible as well. This patch converts the smcd_dev_list spinlock to a mutex. Fixes: c6ba7c9b ("net/smc: add base infrastructure for SMC-D and ISM") Signed-off-by: NUrsula Braun <ubraun@linux.ibm.com> Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
由 Ursula Braun 提交于
Tests showed this BUG: [572555.252867] BUG: sleeping function called from invalid context at kernel/locking/mutex.c:935 [572555.252876] in_atomic(): 1, irqs_disabled(): 0, non_block: 0, pid: 131031, name: smcapp [572555.252879] INFO: lockdep is turned off. [572555.252883] CPU: 1 PID: 131031 Comm: smcapp Tainted: G O 5.7.0-rc3uschi+ #356 [572555.252885] Hardware name: IBM 3906 M03 703 (LPAR) [572555.252887] Call Trace: [572555.252896] [<00000000ac364554>] show_stack+0x94/0xe8 [572555.252901] [<00000000aca1f400>] dump_stack+0xa0/0xe0 [572555.252906] [<00000000ac3c8c10>] ___might_sleep+0x260/0x280 [572555.252910] [<00000000acdc0c98>] __mutex_lock+0x48/0x940 [572555.252912] [<00000000acdc15c2>] mutex_lock_nested+0x32/0x40 [572555.252975] [<000003ff801762d0>] mlx5_lag_get_roce_netdev+0x30/0xc0 [mlx5_core] [572555.252996] [<000003ff801fb3aa>] mlx5_ib_get_netdev+0x3a/0xe0 [mlx5_ib] [572555.253007] [<000003ff80063848>] smc_pnet_find_roce_resource+0x1d8/0x310 [smc] [572555.253011] [<000003ff800602f0>] __smc_connect+0x1f0/0x3e0 [smc] [572555.253015] [<000003ff80060634>] smc_connect+0x154/0x190 [smc] [572555.253022] [<00000000acbed8d4>] __sys_connect+0x94/0xd0 [572555.253025] [<00000000acbef620>] __s390x_sys_socketcall+0x170/0x360 [572555.253028] [<00000000acdc6800>] system_call+0x298/0x2b8 [572555.253030] INFO: lockdep is turned off. Function smc_pnet_find_rdma_dev() might be called from smc_pnet_find_roce_resource(). It holds the smc_ib_devices list spinlock while calling infiniband op get_netdev(). At least for mlx5 the get_netdev operation wants mutex serialization, which conflicts with the smc_ib_devices spinlock. This patch switches the smc_ib_devices spinlock into a mutex to allow sleeping when calling get_netdev(). Fixes: a4cf0443 ("smc: introduce SMC as an IB-client") Signed-off-by: NUrsula Braun <ubraun@linux.ibm.com> Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
由 Karsten Graul 提交于
Wait for pending sends only when smc_switch_conns() found a link to move the connections to. Do not wait during link freeing, this can lead to permanent hang situations. And refuse to provide a new tx slot on an unusable link. Fixes: c6f02ebe ("net/smc: switch connections to alternate link") Reviewed-by: NUrsula Braun <ubraun@linux.ibm.com> Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
由 Karsten Graul 提交于
There might be races in scenarios where both SMC link groups are on the same system. Prevent that by creating separate wait queues for LLC flows and messages. Switch to non-interruptable versions of wait_event() and wake_up() for the llc flow waiter to make sure the waiters get control sequentially. Fine tune the llc_flow_lock to include the assignment of the message. Write to system log when an unexpected message was dropped. And remove an extra indirection and use the existing local variable lgr in smc_llc_enqueue(). Fixes: 555da9af ("net/smc: add event-based llc_flow framework") Reviewed-by: NUrsula Braun <ubraun@linux.ibm.com> Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
- 14 6月, 2020 1 次提交
-
-
由 Masahiro Yamada 提交于
Since commit 84af7a61 ("checkpatch: kconfig: prefer 'help' over '---help---'"), the number of '---help---' has been gradually decreasing, but there are still more than 2400 instances. This commit finishes the conversion. While I touched the lines, I also fixed the indentation. There are a variety of indentation styles found. a) 4 spaces + '---help---' b) 7 spaces + '---help---' c) 8 spaces + '---help---' d) 1 space + 1 tab + '---help---' e) 1 tab + '---help---' (correct indentation) f) 1 tab + 1 space + '---help---' g) 1 tab + 2 spaces + '---help---' In order to convert all of them to 1 tab + 'help', I ran the following commend: $ find . -name 'Kconfig*' | xargs sed -i 's/^[[:space:]]*---help---/\thelp/' Signed-off-by: NMasahiro Yamada <masahiroy@kernel.org>
-
- 31 5月, 2020 1 次提交
-
-
由 Karsten Graul 提交于
Pre-fetch send buffer for the CDC validation message before entering the send_lock. Without that the send call might fail with -EBUSY because there are no free buffers and waiting for buffers is not possible under send_lock. Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Reviewed-by: NUrsula Braun <ubraun@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
- 27 5月, 2020 1 次提交
-
-
由 Dmitry Vyukov 提交于
Netlink policies are generally declared as const. This is safer and prevents potential bugs. Signed-off-by: NDmitry Vyukov <dvyukov@google.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
- 21 5月, 2020 2 次提交
-
-
由 Christoph Hellwig 提交于
Just return 0 for success if it is not present. Signed-off-by: NChristoph Hellwig <hch@lst.de> Signed-off-by: NAl Viro <viro@zeniv.linux.org.uk>
-
由 Christoph Hellwig 提交于
Just return 1 for failure if it is not present. Signed-off-by: NChristoph Hellwig <hch@lst.de> Signed-off-by: NAl Viro <viro@zeniv.linux.org.uk>
-
- 08 5月, 2020 1 次提交
-
-
由 YueHaibing 提交于
Fixes gcc '-Wunused-but-set-variable' warning: net/smc/smc_llc.c: In function 'smc_llc_cli_conf_link': net/smc/smc_llc.c:753:31: warning: variable 'del_llc' set but not used [-Wunused-but-set-variable] struct smc_llc_msg_del_link *del_llc; ^ net/smc/smc_llc.c: In function 'smc_llc_process_srv_delete_link': net/smc/smc_llc.c:1311:33: warning: variable 'del_llc_resp' set but not used [-Wunused-but-set-variable] struct smc_llc_msg_del_link *del_llc_resp; ^ Signed-off-by: NYueHaibing <yuehaibing@huawei.com> Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
- 06 5月, 2020 3 次提交
-
-
由 Jason Gunthorpe 提交于
When a client is added it isn't allowed to fail, but all the client's have various failure paths within their add routines. This creates the very fringe condition where the client was added, failed during add and didn't set the client_data. The core code will then still call other client_data centric ops like remove(), rename(), get_nl_info(), and get_net_dev_by_params() with NULL client_data - which is confusing and unexpected. If the add() callback fails, then do not call any more client ops for the device, even remove. Remove all the now redundant checks for NULL client_data in ops callbacks. Update all the add() callbacks to return error codes appropriately. EOPNOTSUPP is used for cases where the ULP does not support the ib_device - eg because it only works with IB. Link: https://lore.kernel.org/r/20200421172440.387069-1-leon@kernel.orgSigned-off-by: NLeon Romanovsky <leonro@mellanox.com> Acked-by: NUrsula Braun <ubraun@linux.ibm.com> Signed-off-by: NJason Gunthorpe <jgg@mellanox.com>
-
由 YueHaibing 提交于
commit bac6de7b ("net/smc: eliminate cursor read and write calls") left behind this. Signed-off-by: NYueHaibing <yuehaibing@huawei.com> Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
由 Karsten Graul 提交于
Print to system log when SMC links are available or go down, link group state changes or pnetids are applied to and removed from devices. The log entries are triggered by either user configuration actions or adapter activation/deactivation events and are not expected to happen often. The entries help SMC users to keep track of the SMC link group status and to detect when actions are needed (like to add replacements for failed adapters). Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Reviewed-by: NUrsula Braun <ubraun@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
- 05 5月, 2020 12 次提交
-
-
由 Karsten Graul 提交于
During SMC-R link establishment the peers exchange the link_uid that is used for debugging purposes. Save the peer link_uid in smc_link so it can be retrieved by the smc_diag netlink interface. Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Reviewed-by: NUrsula Braun <ubraun@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
由 Karsten Graul 提交于
The link_uid of an SMC-R link is exchanged between SMC peers and its value can be used for debugging purposes. Create a unique link_uid during link initialization and use it in communication with SMC-R peers. Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Reviewed-by: NUrsula Braun <ubraun@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
由 Karsten Graul 提交于
Add helper smcr_lgr_link_deactivate_all() and eliminate duplicate code. In smc_lgr_free(), clear the smc-r links before smc_lgr_free_bufs() is called so buffers are already prepared for free. The usage of the soft parameter in __smc_lgr_terminate() is no longer needed, smc_lgr_free() can be called directly. smc_lgr_terminate_sched() and smc_smcd_terminate() set lgr->freeing to indicate that the link group will be freed soon to avoid unnecessary schedules of the free worker. Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Reviewed-by: NUrsula Braun <ubraun@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
由 Karsten Graul 提交于
Allow to set the reason code for the link group termination, and set meaningful values before termination processing is triggered. This reason code is sent to the peer in the final delete link message. When the LLC request or response layer receives a message type that was not handled, drop a warning and terminate the link group. Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Reviewed-by: NUrsula Braun <ubraun@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
由 Karsten Graul 提交于
New connections must not be assigned to asymmetric links. Add asymmetric link tagging using new link variable link_is_asym. The new helpers smcr_lgr_set_type() and smcr_lgr_set_type_asym() are called to set the state of the link group, and tag all links accordingly. smcr_lgr_conn_assign_link() respects the link tagging and will not assign new connections to links tagged as asymmetric link. Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Reviewed-by: NUrsula Braun <ubraun@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
由 Karsten Graul 提交于
For new connections, assign a link from the link group, using some simple load balancing. Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Reviewed-by: NUrsula Braun <ubraun@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
由 Karsten Graul 提交于
Add smc_llc_send_message_wait() which uses smc_wr_tx_send_wait() to send an LLC message and waits for the message send to complete. smc_llc_send_link_delete_all() calls the new function to send an DELETE_LINK,ALL LLC message. The RFC states that the sender of this type of message needs to wait for the completion event of the message transmission and can terminate the link afterwards. Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Reviewed-by: NUrsula Braun <ubraun@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
由 Karsten Graul 提交于
Introduce smc_wr_tx_send_wait() to send an IB message and wait for the tx completion event of the message. This makes sure that the message is no longer in-flight when the function returns. Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Reviewed-by: NUrsula Braun <ubraun@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
由 Karsten Graul 提交于
Call smc_cdc_msg_validate() when a CDC message with the failover validation bit enabled was received. Validate that the sequence number sent with the message is one we already have received. If not, messages were lost and the connection is terminated using a new abort_work. Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Reviewed-by: NUrsula Braun <ubraun@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
由 Karsten Graul 提交于
When a connection is switched to a new link then a link validation message must be sent to the peer over the new link, containing the sequence number of the last CDC message that was sent over the old link. The peer will validate if this sequence number is the same or lower then the number he received, and abort the connection if messages were lost. Add smcr_cdc_msg_send_validation() to send the message validation message and call it when a connection was switched in smc_switch_cursor(). Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Reviewed-by: NUrsula Braun <ubraun@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
由 Karsten Graul 提交于
Add smc_switch_conns() to switch all connections from a link that is going down. Find an other link to switch the connections to, and switch each connection to the new link. smc_switch_cursor() updates the cursors of a connection to the state of the last successfully sent CDC message. When there is no link to switch to, terminate the link group. Call smc_switch_conns() when a link is going down. And with the possibility that links of connections can switch adapt CDC and TX functions to detect and handle link switches. Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Reviewed-by: NUrsula Braun <ubraun@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
由 Karsten Graul 提交于
When a link goes down and all connections of this link need to be switched to an other link then the producer cursor and the sequence of the last successfully sent CDC message must be known. Add the two fields to the SMC connection and update it in the tx completion handler. And to allow matching of sequences in error cases reset the seqno to the old value in smc_cdc_msg_send() when the actual send failed. Signed-off-by: NKarsten Graul <kgraul@linux.ibm.com> Reviewed-by: NUrsula Braun <ubraun@linux.ibm.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-