      [MIPS] BCM1250: TRDY timeout tweaks for Broadcom SiByte systems · 15a1c514
      Maciej W. Rozycki 提交于
       It was obesrved that at least one older PCI card predating the
      requirement for the TRDY signal to respond within 16 clock ticks actually
      does not meet this rule nor even the power-on defaults of the PCI bridges
      found in development systems built around the Broadcom SiByte SOCs.  Here
      is a patch that bumps up the timeout to the highest finite value supported
      by these chips, which is 255 clock ticks.  The bridges affected are the
      SiByte SOC itself and the SP1011.
          
       This change does not effectively affect systems only having PCI option
      cards installed that meet the TRDY requirement of the current PCI spec.
      The rule was introduced with PCI 2.1, so any older card may make the
      system affected.  If this is the case, performance of the system will
      suffer in return for the card working at all.  If this is a concern, then
      the solution is not to use such cards.
      Signed-off-by: NMaciej W. Rozycki <macro@linux-mips.org>