      Input: smtpe-ts - wait 50mS until polling for pen-up · 77b071e7
      Marek Vasut 提交于
      Wait a little bit longer, 50mS instead of 20mS, until the driver starts
      polling for pen-up. The problematic behavior before this patch is applied
      is as follows. The behavior was observed on the STMPE610QTR controller.
      
      Upon a physical pen-down event, the touchscreen reports one set of x-y-p
      coordinates and a pen-down event. After that, the pen-up polling is
      triggered and since the controller is not ready yet, the polling mistakenly
      detects a pen-up event while the physical state is still such that the pen
      is down on the touch surface.
      
      The pen-up handling flushes the controller FIFO, so after that, all the
      samples in the controller are discarded. The controller becomes ready
      shortly after this bogus pen-up handling and does generate again a pen-down
      interrupt. This time, the controller contains x-y-p samples which all read
      as zero. Since pressure value is zero, this set of samples is effectively
      ignored by userland.
      
      In the end, the driver just bounces between pen-down and bogus pen-up
      handling, generating no useful results. Fix this by giving the controller a
      bit more time before polling it for pen-up.
      Signed-off-by: NMarek Vasut <marex@denx.de>
      Reviewed-by: NViresh Kumar <viresh.kumar@linaro.org>
      Signed-off-by: NDmitry Torokhov <dmitry.torokhov@gmail.com>