提交 fce9d33f 编写于 作者: A Andrew Gabbasov 提交者: Ulf Hansson

mmc: sdhci: fix error conditions for controller reset

Add the case of SET_BLOCK_COUNT command error to the error conditions
check for making a controller reset at request handling finish.
Otherwise, if the SET_BLOCK_COUNT command failed, e.g. with a timeout,
the controller state was not reset, and the next command failed too.

In the case of data error the controller reset is already done in
finish_data() function before sending stop command (if present),
so the finish tasklet should make a reset after data error only
if no stop command existed in the request.

Also, fix the indentation of this condition check to make it more logical.
Signed-off-by: NAndrew Gabbasov <andrew_gabbasov@mentor.com>
Signed-off-by: NUlf Hansson <ulf.hansson@linaro.org>
上级 fbfaf032
......@@ -2144,9 +2144,10 @@ static void sdhci_tasklet_finish(unsigned long param)
*/
if (!(host->flags & SDHCI_DEVICE_DEAD) &&
((mrq->cmd && mrq->cmd->error) ||
(mrq->data && (mrq->data->error ||
(mrq->data->stop && mrq->data->stop->error))) ||
(host->quirks & SDHCI_QUIRK_RESET_AFTER_REQUEST))) {
(mrq->sbc && mrq->sbc->error) ||
(mrq->data && ((mrq->data->error && !mrq->data->stop) ||
(mrq->data->stop && mrq->data->stop->error))) ||
(host->quirks & SDHCI_QUIRK_RESET_AFTER_REQUEST))) {
/* Some controllers need this kick or reset won't work here */
if (host->quirks & SDHCI_QUIRK_CLOCK_BEFORE_RESET)
......