counter: stm32-timer-cnt: fix ceiling miss-alignment with reload register
stable inclusion from stable-5.10.26 commit 6d4e1fed18d04663f5f8981d4500183888e8d8f0 bugzilla: 51363 -------------------------------- commit b14d72ac upstream. Ceiling value may be miss-aligned with what's actually configured into the ARR register. This is seen after probe as currently the ARR value is zero, whereas ceiling value is set to the maximum. So: - reading ceiling reports zero - in case the counter gets enabled without any prior configuration, it won't count. - in case the function gets set by the user 1st, (priv->ceiling) is used. Fix it by getting rid of the cached "priv->ceiling" variable. Rather use the ARR register value directly by using regmap read or write when needed. There should be no drawback on performance as priv->ceiling isn't used in performance critical path. There's also no point in writing ARR while setting function (sms), so it can be safely removed. Fixes: ad29937e ("counter: Add STM32 Timer quadrature encoder") Suggested-by: NWilliam Breathitt Gray <vilhelm.gray@gmail.com> Signed-off-by: NFabrice Gasnier <fabrice.gasnier@foss.st.com> Acked-by: NWilliam Breathitt Gray <vilhelm.gray@gmail.com> Cc: <Stable@vger.kernel.org> Link: https://lore.kernel.org/r/1614793789-10346-1-git-send-email-fabrice.gasnier@foss.st.comSigned-off-by: NJonathan Cameron <Jonathan.Cameron@huawei.com> Signed-off-by: NGreg Kroah-Hartman <gregkh@linuxfoundation.org> Signed-off-by: NChen Jun <chenjun102@huawei.com> Acked-by: N Weilong Chen <chenweilong@huawei.com> Signed-off-by: NZheng Zengkai <zhengzengkai@huawei.com>