提交 eee6c32f 编写于 作者: A Albert Lee 提交者: Jeff Garzik

[PATCH] libata-dev: handle DRQ=1 ERR=1 (revised)

Handle DRQ=1 ERR=1 situation. Revised according to what IDE try_to_flush_leftover_data() does.

Changes:
 - For ATA PIO writes and ATAPI devices, just stop the HSM and let EH handle it.
 - For ATA PIO reads, read only one block of junk data and then let EH handle it.
Signed-off-by: NAlbert Lee <albertcc@tw.ibm.com>
Signed-off-by: NJeff Garzik <jeff@garzik.org>
上级 6e07e164
......@@ -3640,13 +3640,16 @@ static int ata_hsm_move(struct ata_port *ap, struct ata_queued_cmd *qc,
/* Device should not ask for data transfer (DRQ=1)
* when it finds something wrong.
* Anyway, we respect DRQ here and let HSM go on
* without changing hsm_task_state to HSM_ST_ERR.
* We ignore DRQ here and stop the HSM by
* changing hsm_task_state to HSM_ST_ERR and
* let the EH abort the command or reset the device.
*/
if (unlikely(status & (ATA_ERR | ATA_DF))) {
printk(KERN_WARNING "ata%d: DRQ=1 with device error, dev_stat 0x%X\n",
ap->id, status);
qc->err_mask |= AC_ERR_DEV;
ap->hsm_task_state = HSM_ST_ERR;
goto fsm_start;
}
/* Send the CDB (atapi) or the first data block (ata pio out).
......@@ -3693,13 +3696,16 @@ static int ata_hsm_move(struct ata_port *ap, struct ata_queued_cmd *qc,
/* Device should not ask for data transfer (DRQ=1)
* when it finds something wrong.
* Anyway, we respect DRQ here and let HSM go on
* without changing hsm_task_state to HSM_ST_ERR.
* We ignore DRQ here and stop the HSM by
* changing hsm_task_state to HSM_ST_ERR and
* let the EH abort the command or reset the device.
*/
if (unlikely(status & (ATA_ERR | ATA_DF))) {
printk(KERN_WARNING "ata%d: DRQ=1 with device error, dev_stat 0x%X\n",
ap->id, status);
qc->err_mask |= AC_ERR_DEV;
ap->hsm_task_state = HSM_ST_ERR;
goto fsm_start;
}
atapi_pio_bytes(qc);
......@@ -3717,20 +3723,32 @@ static int ata_hsm_move(struct ata_port *ap, struct ata_queued_cmd *qc,
goto fsm_start;
}
/* Some devices may ask for data transfer (DRQ=1)
* alone with ERR=1 for PIO reads.
* We respect DRQ here and let HSM go on without
* changing hsm_task_state to HSM_ST_ERR.
/* For PIO reads, some devices may ask for
* data transfer (DRQ=1) alone with ERR=1.
* We respect DRQ here and transfer one
* block of junk data before changing the
* hsm_task_state to HSM_ST_ERR.
*
* For PIO writes, ERR=1 DRQ=1 doesn't make
* sense since the data block has been
* transferred to the device.
*/
if (unlikely(status & (ATA_ERR | ATA_DF))) {
/* For writes, ERR=1 DRQ=1 doesn't make
* sense since the data block has been
* transferred to the device.
*/
WARN_ON(qc->tf.flags & ATA_TFLAG_WRITE);
/* data might be corrputed */
qc->err_mask |= AC_ERR_DEV;
if (!(qc->tf.flags & ATA_TFLAG_WRITE)) {
ata_pio_sectors(qc);
ata_altstatus(ap);
status = ata_wait_idle(ap);
}
/* ata_pio_sectors() might change the
* state to HSM_ST_LAST. so, the state
* is changed after ata_pio_sectors().
*/
ap->hsm_task_state = HSM_ST_ERR;
goto fsm_start;
}
ata_pio_sectors(qc);
......