提交 ea70d791 编写于 作者: B Bartosz Golaszewski 提交者: Richard Weinberger

um: define set_pte_at() as a static inline function, not a macro

When defined as macro, the mm argument is unused and subsequently the
variable passed as mm is considered unused by the compiler. This fixes
a build warning.
Signed-off-by: NBartosz Golaszewski <bgolaszewski@baylibre.com>
Reviewed-by: NGeert Uytterhoeven <geert@linux-m68k.org>
Reviewed-by: NAnton Ivanov <anton.ivanov@cambridgegreys.com>
Acked-by: NAnton Ivanov <anton.ivanov@cambridgegreys.com>
Signed-off-by: NRichard Weinberger <richard@nod.at>
上级 0d4e5ac7
......@@ -263,7 +263,12 @@ static inline void set_pte(pte_t *pteptr, pte_t pteval)
*pteptr = pte_mknewpage(*pteptr);
if(pte_present(*pteptr)) *pteptr = pte_mknewprot(*pteptr);
}
#define set_pte_at(mm,addr,ptep,pteval) set_pte(ptep,pteval)
static inline void set_pte_at(struct mm_struct *mm, unsigned long addr,
pte_t *pteptr, pte_t pteval)
{
set_pte(pteptr, pteval);
}
#define __HAVE_ARCH_PTE_SAME
static inline int pte_same(pte_t pte_a, pte_t pte_b)
......
Markdown is supported
0% .
You are about to add 0 people to the discussion. Proceed with caution.
先完成此消息的编辑!
想要评论请 注册