wl1251: timeout one too soon in wl1251_boot_run_firmware()
`loop' reaches INIT_LOOP + 1 after the loop. so if ACX_INTR_INIT_COMPLETE occurs in the last iteration the write occurs but also the error out as if a timeout occurred. This is probably very unlikely to ever occur. Signed-off-by: NRoel Kluin <roel.kluin@gmail.com> Acked-by: NKalle Valo <kalle.valo@nokia.com> Signed-off-by: NJohn W. Linville <linville@tuxdriver.com>