提交 e8796c6c 编写于 作者: M Michael Haener 提交者: Andy Shevchenko

platform/x86: pmc_atom: Add Siemens CONNECT X300 to critclk_systems DMI table

The CONNECT X300 uses the PMC clock for on-board components and gets
stuck during boot if the clock is disabled. Therefore, add this
device to the critical systems list.
Tested on CONNECT X300.

Fixes: 648e9218 ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Signed-off-by: NMichael Haener <michael.haener@siemens.com>
Signed-off-by: NAndy Shevchenko <andriy.shevchenko@linux.intel.com>
上级 133b2ace
...@@ -429,6 +429,14 @@ static const struct dmi_system_id critclk_systems[] = { ...@@ -429,6 +429,14 @@ static const struct dmi_system_id critclk_systems[] = {
DMI_MATCH(DMI_PRODUCT_VERSION, "6AV7882-0"), DMI_MATCH(DMI_PRODUCT_VERSION, "6AV7882-0"),
}, },
}, },
{
.ident = "CONNECT X300",
.matches = {
DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"),
DMI_MATCH(DMI_PRODUCT_VERSION, "A5E45074588"),
},
},
{ /*sentinel*/ } { /*sentinel*/ }
}; };
......