提交 df7507b5 编写于 作者: N Niklas Söderlund 提交者: Ulf Hansson

mmc: renesas_sdhi: remove workaround for HS400 clock

The driver sets an incorrect clock and depends on the clock driver
knowledge of this incorrect setting to still set a 200Mhz SDn clock.
Instead of spreading the workaround between the two drivers the clock
driver should be made aware of the ES versions where the special clock
handling is needed no need to keep this workaround in the SDHI driver.
Signed-off-by: NNiklas Söderlund <niklas.soderlund+renesas@ragnatech.se>
Reviewed-by: NWolfram Sang <wsa+renesas@sang-engineering.com>
Tested-by: NWolfram Sang <wsa+renesas@sang-engineering.com>
Reviewed-by: NSimon Horman <horms+renesas@verge.net.au>
Signed-off-by: NUlf Hansson <ulf.hansson@linaro.org>
上级 cd7a0d21
......@@ -163,15 +163,6 @@ static void renesas_sdhi_set_clock(struct tmio_mmc_host *host,
if (new_clock == 0)
goto out;
/*
* Both HS400 and HS200/SD104 set 200MHz, but some devices need to
* set 400MHz to distinguish the CPG settings in HS400.
*/
if (host->mmc->ios.timing == MMC_TIMING_MMC_HS400 &&
host->pdata->flags & TMIO_MMC_HAVE_4TAP_HS400 &&
new_clock == 200000000)
new_clock = 400000000;
clock = renesas_sdhi_clk_update(host, new_clock) / 512;
for (clk = 0x80000080; new_clock >= (clock << 1); clk >>= 1)
......