提交 d8cce3a1 编写于 作者: H Heiner Kallweit 提交者: David S. Miller

net: phy: improve get_phy_id

Only caller of get_phy_id() is get_phy_device(). There a PHY ID of
0xffffffff is translated back to -ENODEV. So we can avoid some
overhead by returning -ENODEV directly.
Signed-off-by: NHeiner Kallweit <hkallweit1@gmail.com>
Signed-off-by: NDavid S. Miller <davem@davemloft.net>
上级 e302c2a5
......@@ -773,15 +773,8 @@ static int get_phy_id(struct mii_bus *bus, int addr, u32 *phy_id,
/* Grab the bits from PHYIR1, and put them in the upper half */
phy_reg = mdiobus_read(bus, addr, MII_PHYSID1);
if (phy_reg < 0) {
/* if there is no device, return without an error so scanning
* the bus works properly
*/
if (phy_reg == -EIO || phy_reg == -ENODEV) {
*phy_id = 0xffffffff;
return 0;
}
return -EIO;
/* returning -ENODEV doesn't stop bus scanning */
return (phy_reg == -EIO || phy_reg == -ENODEV) ? -ENODEV : -EIO;
}
*phy_id = (phy_reg & 0xffff) << 16;
......