i2c: sirf: tune the divider to make i2c bus freq more accurate
In prima2 and atlas7, due to some hardware design issue. we need to adjust the divider ratio a little according to i2c bus frequency ranges. Since i2c is open drain interface that allows the slave to stall the transaction by holding the SCL line at '0', the RTL implementation is waiting for SCL feedback from the pin after setting it to High-Z ('1'). This wait adds to the high-time interval counter few cycles of the input synchronization (depending on the SCL_FILTER_REG field), and also the time it takes for the board pull-up resistor to rise the SCL line. For slow SCL settings these additions are negligible, but they start to affect the speed when clock is set to faster frequencies. This patch is based on the actual tests, and it makes SCL more accurate. Signed-off-by: NGuoying Zhang <Guoying.Zhang@csr.com> Signed-off-by: NBarry Song <Baohua.Song@csr.com> Signed-off-by: NWolfram Sang <wsa@the-dreams.de>