提交 cf8088c5 编写于 作者: T Thomas Petazzoni 提交者: Jason Cooper

arm: mvebu: fix length of Ethernet registers area in .dtsi

The length of the registers area for the Marvell 370/XP Ethernet
controller was incorrect in the .dtsi: 0x2400 while it should have
been 0x4000. Until now, this problem wasn't noticed because there was
a large static mapping for all I/Os set up by ->map_io(). But since
we're going to get rid of this static mapping, we need to ensure that
the register areas are properly sized.
Signed-off-by: NThomas Petazzoni <thomas.petazzoni@free-electrons.com>
Signed-off-by: NJason Cooper <jason@lakedaemon.net>
上级 911492de
......@@ -96,7 +96,7 @@
ethernet@70000 {
compatible = "marvell,armada-370-neta";
reg = <0x70000 0x2500>;
reg = <0x70000 0x4000>;
interrupts = <8>;
clocks = <&gateclk 4>;
status = "disabled";
......@@ -104,7 +104,7 @@
ethernet@74000 {
compatible = "marvell,armada-370-neta";
reg = <0x74000 0x2500>;
reg = <0x74000 0x4000>;
interrupts = <10>;
clocks = <&gateclk 3>;
status = "disabled";
......
......@@ -107,7 +107,7 @@
ethernet@34000 {
compatible = "marvell,armada-370-neta";
reg = <0x34000 0x2500>;
reg = <0x34000 0x4000>;
interrupts = <14>;
clocks = <&gateclk 1>;
status = "disabled";
......
......@@ -88,7 +88,7 @@
ethernet@30000 {
compatible = "marvell,armada-370-neta";
reg = <0x30000 0x2500>;
reg = <0x30000 0x4000>;
interrupts = <12>;
clocks = <&gateclk 2>;
status = "disabled";
......