[POWERPC] Generalize tsi108 PHY types
Add a phy_type field to the tsi108 ethernet structures to indicate which PHY is used on a board. This is derived from the "compatible" property in the ethernet-phy node of the device tree. The default remains the MV88E PHY. Also, convert the setup code to use of_get_mac_address instead of hard coding a lookup for the "address" property in the ethernet node. Signed-off-by: NJosh Boyer <jwboyer@linux.vnet.ibm.com> Acked-by: NOlof Johansson <olof@lixom.net> Signed-off-by: NPaul Mackerras <paulus@samba.org>