drm/amd/display: programming last delta in output transfer function LUT to a correct value
[Why] Currently DAL programs negative slope for the last point of output transfer function curve. [How] Applying a check for the last PWL point for RGB values not to be smaller than previous. If smaller, initialize the last point values to a sum of previous PWL value and previous PWL delta; Signed-off-by: NVladimir Stempen <vladimir.stempen@amd.com> Reviewed-by: NTony Cheng <Tony.Cheng@amd.com> Acked-by: NJun Lei <Jun.Lei@amd.com> Acked-by: NRodrigo Siqueira <Rodrigo.Siqueira@amd.com> Acked-by: NHarry Wentland <harry.wentland@amd.com> Signed-off-by: NAlex Deucher <alexander.deucher@amd.com>