EDAC/amd64: Support more than two Unified Memory Controllers
The first few models of Family 17h all had 2 Unified Memory Controllers per Die, so this was treated as a fixed value. However, future systems may have more Unified Memory Controllers per Die. Related to this, the channel number and base address of a Unified Memory Controller were found by matching on fixed, known values. However, current and future systems follow this pattern for the channel number and base address of a Unified Memory Controller: 0xYXXXXX, where Y is the channel number. So matching on hardcoded values is not necessary. Set the number of Unified Memory Controllers at driver init time based on the family/model. Also, update the functions that find the channel number and base address of a Unified Memory Controller to support more than two. [ bp: Move num_umcs into the .c file and simplify comment. ] Signed-off-by: NYazen Ghannam <yazen.ghannam@amd.com> Signed-off-by: NBorislav Petkov <bp@suse.de> Tested-by: NKim Phillips <kim.phillips@amd.com> Cc: James Morse <james.morse@arm.com> Cc: Mauro Carvalho Chehab <mchehab@kernel.org> Cc: linux-edac <linux-edac@vger.kernel.org> Link: https://lkml.kernel.org/r/20190228153558.127292-3-Yazen.Ghannam@amd.com