提交 a6e03dd4 编写于 作者: T Thomas Petazzoni 提交者: Jason Cooper

ARM: mvebu: ensure the mdio node has a clock reference on Armada 370/XP

The mvmdio driver accesses some register of the Ethernet unit. It
therefore takes a reference and enables a clock. However, on Armada
370/XP, no clock specification was given in the Device Tree, which
leads the mvmdio driver to fail when being used as a module and loaded
before the mvneta driver: it tries to access a register from a
hardware unit that isn't clocked.

Cc: stable@vger.kernel.org
Signed-off-by: NThomas Petazzoni <thomas.petazzoni@free-electrons.com>
Link: https://lkml.kernel.org/r/1395790439-21332-2-git-send-email-thomas.petazzoni@free-electrons.comAcked-by: NAndrew Lunn <andrew@lunn.ch>
Acked-by: NGregory CLEMENT <gregory.clement@free-electrons.com>
Signed-off-by: NJason Cooper <jason@lakedaemon.net>
上级 dcdf9cfc
......@@ -230,6 +230,7 @@
#size-cells = <0>;
compatible = "marvell,orion-mdio";
reg = <0x72004 0x4>;
clocks = <&gateclk 4>;
};
eth1: ethernet@74000 {
......