media: irs1125: Keep HW in sync after imager reset
raspberrypi inclusion category: feature bugzilla: 50432 -------------------------------- When closing the video device, the irs1125 is put in power down state. To keep V4L2 ctrls and the HW in sync, v4l2_ctrl_handler_setup is called after power up. The compound ctrl IRS1125_CID_MOD_PLL however has a default value of all zeros, which puts the imager into a non responding state. Thus, this ctrl is not written by the driver into HW after power up. The userspace has to take care to write senseful data. Signed-off-by: NMarkus Proeller <markus.proeller@pieye.org> Signed-off-by: NFang Yafen <yafen@iscas.ac.cn> Signed-off-by: NZheng Zengkai <zhengzengkai@huawei.com>