e1000e: issues in Sx on 82577/8/9
A workaround was previously put in the driver to reset the device when transitioning to Sx in order to activate the changed settings of the PHY OEM bits (Low Power Link Up, or LPLU, and GbE disable configuration) for 82577/8/9 devices. After further review, it was found such a reset can cause the 82579 to confuse which version of 82579 it actually is and broke LPLU on all 82577/8/9 devices. The workaround during an S0->Sx transition on 82579 (instead of resetting the PHY) is to restart auto-negotiation after the OEM bits are configured; the restart of auto-negotiation activates the new OEM bits as does the reset. With 82577/8, the reset is changed to a generic reset which fixes the LPLU bits getting set wrong. Signed-off-by: NBruce Allan <bruce.w.allan@intel.com> Tested-by: NAaron Brown <aaron.f.brown@intel.com> Signed-off-by: NJeff Kirsher <jeffrey.t.kirsher@intel.com>
Showing
想要评论请 注册 或 登录