提交 8e365790 编写于 作者: M Manuel Lauss 提交者: Ralf Baechle

MIPS: Alchemy: Increase minimum timeout for 32kHz timer.

Since a clocksource change post 3.2-rc1, tasks on my DB1500 board
hang after random amounts of time (from a few minutes to a few hours),
regardless of load.  Debugging showed that the compare-match register
value is a few seconds lower than the current counter value.

The minimum value of 8 was initialy determined by a trial-and-error
approach.  Currently it is sufficient for all Alchemys (without PCI
apparently), independent of CPU clock;  only the DB1500 and DB1550
boards experience these timer-related tasks hangs now.

This patch increases the minimum timeout by 1 (to 9 counter ticks)
which seems sufficient since the systems are still working perfectly
fine after over 24 hours.
Signed-off-by: NManuel Lauss <manuel.lauss@googlemail.com>
Cc: linux-mips@linux-mips.org
Patchwork: https://patchwork.linux-mips.org/patch/3214/Signed-off-by: NRalf Baechle <ralf@linux-mips.org>
上级 193fb426
......@@ -146,7 +146,7 @@ static int __init alchemy_time_init(unsigned int m2int)
cd->shift = 32;
cd->mult = div_sc(32768, NSEC_PER_SEC, cd->shift);
cd->max_delta_ns = clockevent_delta2ns(0xffffffff, cd);
cd->min_delta_ns = clockevent_delta2ns(8, cd); /* ~0.25ms */
cd->min_delta_ns = clockevent_delta2ns(9, cd); /* ~0.28ms */
clockevents_register_device(cd);
setup_irq(m2int, &au1x_rtcmatch2_irqaction);
......
Markdown is supported