regulator: core: Resolve supply name earlier to prevent double-init
Previously, an unresolved regulator supply reference upon calling regulator_register on an always-on or boot-on regulator caused set_machine_constraints to be called twice. This in turn may initialize the regulator twice, leading to voltage glitches that are timing-dependent. A simple, unrelated configuration change may be enough to hide this problem, only to be surfaced by chance. One such example is the SD-Card voltage regulator in a NanoPI R4S that would not initialize reliably unless the registration flow was just complex enough to allow the regulator to properly reset between calls. Fix this by re-arranging regulator_register, trying resolve the regulator's supply early enough that set_machine_constraints does not need to be called twice. Signed-off-by: NChristian Kohlschütter <christian@kohlschutter.com> Link: https://lore.kernel.org/r/20220818124646.6005-1-christian@kohlschutter.comSigned-off-by: NMark Brown <broonie@kernel.org>