staging: comedi: pcmad: properly handle analog input encoding configuration
The comedi_config utility is used to attach to this board. One of the configuration options passed by the user sets the analog input encoding for straight binary or two's complement data. The hardware produces straight binary data when jumpered for 5V unipolar inputs and two's complement data when jumpered for +-10V bipolar inputs. Use the configuration option to correctly set the comedi_subdevice range_table. We can then use a helper function to determine what the range is when reading the analog inputs. This allows removing the 'twos_comp' variable from the private data (which was actually never used). Since the private data is now empty, remove it completely. Signed-off-by: NH Hartley Sweeten <hsweeten@visionengravers.com> Cc: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: NGreg Kroah-Hartman <gregkh@linuxfoundation.org>