提交 7976b1e9 编写于 作者: S Sara Sharon 提交者: Johannes Berg

mac80211: ignore quiet mode in probe

Some buggy APs keep the CSA IE in probes after the channel
switch was completed and can silence us for no good reason.
Apply quiet mode only from beacons. If there is real channel
switch going on, we will see the beacon anyway.
Signed-off-by: NSara Sharon <sara.sharon@intel.com>
Signed-off-by: NLuca Coelho <luciano.coelho@intel.com>
Signed-off-by: NJohannes Berg <johannes.berg@intel.com>
上级 9792875c
......@@ -1316,7 +1316,7 @@ ieee80211_sta_process_chanswitch(struct ieee80211_sub_if_data *sdata,
if (!res) {
ch_switch.timestamp = timestamp;
ch_switch.device_timestamp = device_timestamp;
ch_switch.block_tx = csa_ie.mode;
ch_switch.block_tx = beacon ? csa_ie.mode : 0;
ch_switch.chandef = csa_ie.chandef;
ch_switch.count = csa_ie.count;
ch_switch.delay = csa_ie.max_switch_time;
......@@ -1409,7 +1409,7 @@ ieee80211_sta_process_chanswitch(struct ieee80211_sub_if_data *sdata,
sdata->vif.csa_active = true;
sdata->csa_chandef = csa_ie.chandef;
sdata->csa_block_tx = csa_ie.mode;
sdata->csa_block_tx = ch_switch.block_tx;
ifmgd->csa_ignored_same_chan = false;
if (sdata->csa_block_tx)
......@@ -1443,7 +1443,7 @@ ieee80211_sta_process_chanswitch(struct ieee80211_sub_if_data *sdata,
* reset when the disconnection worker runs.
*/
sdata->vif.csa_active = true;
sdata->csa_block_tx = csa_ie.mode;
sdata->csa_block_tx = ch_switch.block_tx;
ieee80211_queue_work(&local->hw, &ifmgd->csa_connection_drop_work);
mutex_unlock(&local->chanctx_mtx);
......