clk: at91: usb: fix at91sam9x5 recalc, round and set rate
First check for rate == 0 in set_rate and round_rate to avoid div by zero. Then, in order to get the closest rate, round all divisions to the closest result instead of rounding them down. Signed-off-by: NBoris Brezillon <boris.brezillon@free-electrons.com> Acked-by: NNicolas Ferre <nicolas.ferre@atmel.com> Signed-off-by: NMichael Turquette <mturquette@linaro.org>