提交 68fa61c0 编写于 作者: T Thomas Gleixner

hrtimers: Reorder clock bases

The ordering of the clock bases is historical due to the
CLOCK_REALTIME and CLOCK_MONOTONIC constants. Now the hrtimer bases
have their own enumeration due to the gap between CLOCK_MONOTONIC and
CLOCK_BOOTTIME. So we can be more clever as most timers end up on the
CLOCK_MONOTONIC base due to the virtue of POSIX declaring that
relative CLOCK_REALTIME timers are not affected by time changes. In
desktop environments this is slowly changing as applications switch to
absolute timers, but I've observed empty CLOCK_REALTIME bases often
enough. There is no performance penalty or overhead when
CLOCK_REALTIME timers are active, but in case they are not we don't
skip over a full cache line.
Signed-off-by: NThomas Gleixner <tglx@linutronix.de>
Reviewed-by: NPeter Zijlstra <peterz@infradead.org>
上级 ab8177bc
......@@ -153,8 +153,8 @@ struct hrtimer_clock_base {
};
enum hrtimer_base_type {
HRTIMER_BASE_REALTIME,
HRTIMER_BASE_MONOTONIC,
HRTIMER_BASE_REALTIME,
HRTIMER_BASE_BOOTTIME,
HRTIMER_MAX_CLOCK_BASES,
};
......
......@@ -63,18 +63,18 @@ DEFINE_PER_CPU(struct hrtimer_cpu_base, hrtimer_bases) =
.clock_base =
{
{
.index = HRTIMER_BASE_REALTIME,
.clockid = CLOCK_REALTIME,
.get_time = &ktime_get_real,
.resolution = KTIME_LOW_RES,
},
{
.index = HRTIMER_BASE_MONOTONIC,
.clockid = CLOCK_MONOTONIC,
.get_time = &ktime_get,
.resolution = KTIME_LOW_RES,
},
{
.index = HRTIMER_BASE_REALTIME,
.clockid = CLOCK_REALTIME,
.get_time = &ktime_get_real,
.resolution = KTIME_LOW_RES,
},
{
.index = HRTIMER_BASE_BOOTTIME,
.clockid = CLOCK_BOOTTIME,
......
Markdown is supported