platform/x86: hp-wmi: Use zero insize parameter only when supported
commit be9d73e6 ("platform/x86: hp-wmi: Fix 0x05 error code reported by several WMI calls") and commit 12b19f14 ("platform/x86: hp-wmi: Fix hp_wmi_read_int() reporting error (0x05)") cause ACPI BIOS Error (bug): Attempt to CreateField of length zero (20211217/dsopcode-133) because of the ACPI method HWMC, which unconditionally creates a Field of size (insize*8) bits: CreateField (Arg1, 0x80, (Local5 * 0x08), DAIN) In cases where args->insize = 0, the Field size is 0, resulting in an error. Fix this by using zero insize only if 0x5 error code is returned Tested on Omen 15 AMD (2020) board ID: 8786. Fixes: be9d73e6 ("platform/x86: hp-wmi: Fix 0x05 error code reported by several WMI calls") Signed-off-by: NBedant Patnaik <bedant.patnaik@gmail.com> Tested-by: NJorge Lopez <jorge.lopez2@hp.com> Link: https://lore.kernel.org/r/41be46743d21c78741232a47bbb5f1cdbcc3d21e.camel@gmail.comReviewed-by: NHans de Goede <hdegoede@redhat.com> Signed-off-by: NHans de Goede <hdegoede@redhat.com>