提交 6481c73c 编写于 作者: M Miguel Vadillo 提交者: Paul Walmsley

OMAP2+: hwmod: Enable module in shutdown to access sysconfig

When calling the shutdown, the module may be already in idle.
Accessing the sysconfig register will then lead to a crash.
In that case, re-enable the module in order to allow the access
to the sysconfig register.
Signed-off-by: NMiguel Vadillo <vadillo@ti.com>
Signed-off-by: NBenoit Cousson <b-cousson@ti.com>
Signed-off-by: NPaul Walmsley <paul@pwsan.com>
上级 c614ebf6
......@@ -1396,8 +1396,11 @@ static int _shutdown(struct omap_hwmod *oh)
}
}
if (oh->class->sysc)
if (oh->class->sysc) {
if (oh->_state == _HWMOD_STATE_IDLE)
_enable(oh);
_shutdown_sysc(oh);
}
/*
* If an IP contains only one HW reset line, then assert it
......