thermal/core/thermal_of: Stop zone device before unregistering it

Zone device is enabled after thermal_zone_of_sensor_register() completion,
but it's not disabled before senor is unregistered, leaving temperature
polling active. This results in accessing a disabled zone device and
produces a warning about this problem. Stop zone device before
unregistering it in order to fix this "use-after-free" problem.
Signed-off-by: NDmitry Osipenko <digetx@gmail.com>
Signed-off-by: NDaniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20210616190417.32214-3-digetx@gmail.com
上级 1aab6b81
...@@ -559,6 +559,9 @@ void thermal_zone_of_sensor_unregister(struct device *dev, ...@@ -559,6 +559,9 @@ void thermal_zone_of_sensor_unregister(struct device *dev,
if (!tz) if (!tz)
return; return;
/* stop temperature polling */
thermal_zone_device_disable(tzd);
mutex_lock(&tzd->lock); mutex_lock(&tzd->lock);
tzd->ops->get_temp = NULL; tzd->ops->get_temp = NULL;
tzd->ops->get_trend = NULL; tzd->ops->get_trend = NULL;
......