powerpc/xmon: Use bitwise calculations in_breakpoint_table()
A modulo operation is used for calculating the current offset from a breakpoint within the breakpoint table. As instruction lengths are always a power of 2, this can be replaced with a bitwise 'and'. The current check for word alignment can be replaced with checking that the lower 2 bits are not set. Suggested-by: NChristophe Leroy <christophe.leroy@c-s.fr> Signed-off-by: NJordan Niethe <jniethe5@gmail.com> Signed-off-by: NMichael Ellerman <mpe@ellerman.id.au> Reviewed-by: NAlistair Popple <alistair@popple.id.au> Link: https://lore.kernel.org/r/20200506034050.24806-5-jniethe5@gmail.com