smsc911x: enforce read-after-write timing restriction on eeprom access
The LAN911x datasheet specifies a minimum delay of 45ns between a write of E2P_DATA and any read. This patch adds a single dummy read of BYTE_TEST to enforce this timing constraint. Signed-off-by: NSteve Glendinning <steve.glendinning@smsc.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>