提交 57d60b1b 编写于 作者: G Guenter Roeck

hwmon: (emc1403) Add driver documentation

With the driver now supporting several chip variants,
it is about time to document what is supported.
Signed-off-by: NGuenter Roeck <linux@roeck-us.net>
上级 a9622663
Kernel driver emc1403
=====================
Supported chips:
* SMSC / Microchip EMC1402, EMC1412
Addresses scanned: I2C 0x18, 0x1c, 0x29, 0x4c, 0x4d, 0x5c
Prefix: 'emc1402'
Datasheets:
http://ww1.microchip.com/downloads/en/DeviceDoc/1412.pdf
http://ww1.microchip.com/downloads/en/DeviceDoc/1402.pdf
* SMSC / Microchip EMC1403, EMC1404, EMC1413, EMC1414
Addresses scanned: I2C 0x18, 0x29, 0x4c, 0x4d
Prefix: 'emc1403', 'emc1404'
Datasheets:
http://ww1.microchip.com/downloads/en/DeviceDoc/1403_1404.pdf
http://ww1.microchip.com/downloads/en/DeviceDoc/1413_1414.pdf
* SMSC / Microchip EMC1422
Addresses scanned: I2C 0x4c
Prefix: 'emc1422'
Datasheet:
http://ww1.microchip.com/downloads/en/DeviceDoc/1422.pdf
* SMSC / Microchip EMC1423, EMC1424
Addresses scanned: I2C 0x4c
Prefix: 'emc1423', 'emc1424'
Datasheet:
http://ww1.microchip.com/downloads/en/DeviceDoc/1423_1424.pdf
Author:
Kalhan Trisal <kalhan.trisal@intel.com
Description
-----------
The Standard Microsystems Corporation (SMSC) / Microchip EMC14xx chips
contain up to four temperature sensors. EMC14x2 support two sensors
(one internal, one external). EMC14x3 support three sensors (one internal,
two external), and EMC14x4 support four sensors (one internal, three
external).
The chips implement three limits for each sensor: low (tempX_min), high
(tempX_max) and critical (tempX_crit.) The chips also implement an
hysteresis mechanism which applies to all limits. The relative difference
is stored in a single register on the chip, which means that the relative
difference between the limit and its hysteresis is always the same for
all three limits.
This implementation detail implies the following:
* When setting a limit, its hysteresis will automatically follow, the
difference staying unchanged. For example, if the old critical limit
was 80 degrees C, and the hysteresis was 75 degrees C, and you change
the critical limit to 90 degrees C, then the hysteresis will
automatically change to 85 degrees C.
* While hysteresis limits can be set for all critical limits, setting a single
hysteresis value affects the hysteresis values for all limits on all sensors.
* The limits should be set before the hysteresis.