提交 568c46c9 编写于 作者: J Jason Gerecke 提交者: Xie XiuQi

HID: wacom: Correct distance scale for 2nd-gen Intuos devices

commit b72fb1dc upstream.

Distance values reported by 2nd-gen Intuos tablets are on an inverted
scale (0 == far, 63 == near). We need to change them over to a normal
scale before reporting to userspace or else userspace drivers and
applications can get confused.

Ref: https://github.com/linuxwacom/input-wacom/issues/98
Fixes: eda01dab ("HID: wacom: Add four new Intuos devices")
Signed-off-by: NJason Gerecke <jason.gerecke@wacom.com>
Cc: <stable@vger.kernel.org> # v4.4+
Signed-off-by: NJiri Kosina <jkosina@suse.cz>
Signed-off-by: NGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Signed-off-by: NYang Yingliang <yangyingliang@huawei.com>
上级 0d4a1d44
......@@ -848,6 +848,8 @@ static int wacom_intuos_general(struct wacom_wac *wacom)
y >>= 1;
distance >>= 1;
}
if (features->type == INTUOSHT2)
distance = features->distance_max - distance;
input_report_abs(input, ABS_X, x);
input_report_abs(input, ABS_Y, y);
input_report_abs(input, ABS_DISTANCE, distance);
......