PM / core: Fix supplier device runtime PM usage counter imbalance
If a device link is added via device_link_add() by the driver of the link's consumer device, the supplier's runtime PM usage counter is going to be dropped by the pm_runtime_put_suppliers() call in driver_probe_device(). However, in that case it is not incremented unless the supplier driver is already present and the link is not stateless. That leads to a runtime PM usage counter imbalance for the supplier device in a few cases. To prevent that from happening, bump up the supplier runtime PM usage counter in device_link_add() for all links with the DL_FLAG_PM_RUNTIME flag set that are added at the consumer probe time. Use pm_runtime_get_noresume() for that as the callers of device_link_add() who want the supplier to be resumed by it are expected to pass DL_FLAG_RPM_ACTIVE in flags to it anyway, but additionally resume the supplier if the link is added during consumer driver probe to retain the existing behavior for the callers depending on it. Fixes: 21d5c57b (PM / runtime: Use device links) Reported-by: NUlf Hansson <ulf.hansson@linaro.org> Reviewed-by: NUlf Hansson <ulf.hansson@linaro.org> Tested-by: NMarek Szyprowski <m.szyprowski@samsung.com> Cc: 4.10+ <stable@vger.kernel.org> # 4.10+ Signed-off-by: NRafael J. Wysocki <rafael.j.wysocki@intel.com>