提交 4724e271 编写于 作者: N NeilBrown 提交者: Kishon Vijay Abraham I

phy: twl4030-usb: remove incorrect pm_runtime_get_sync() in probe function.

The USB phy should initialize with power-off, and will be powered on
by the USB system when a cable connection is detected.

Having this pm_runtime_get_sync() during probe causes the phy to
*always* be powered on.
Removing it returns to sensible power management.

Fixes: 96be39abSigned-off-by: NNeilBrown <neil@brown.name>
Signed-off-by: NKishon Vijay Abraham I <kishon@ti.com>
上级 186ecebe
......@@ -715,7 +715,6 @@ static int twl4030_usb_probe(struct platform_device *pdev)
pm_runtime_use_autosuspend(&pdev->dev);
pm_runtime_set_autosuspend_delay(&pdev->dev, 2000);
pm_runtime_enable(&pdev->dev);
pm_runtime_get_sync(&pdev->dev);
/* Our job is to use irqs and status from the power module
* to keep the transceiver disabled when nothing's connected.
......
Markdown is supported