s390/idle: fix accounting with machine checks
When a machine check interrupt is triggered during idle, the code is using the async timer/clock for idle time calculation. It should use the machine check enter timer/clock which is passed to the macro. Fixes: 0b0ed657 ("s390: remove critical section cleanup from entry.S") Cc: <stable@vger.kernel.org> # 5.8 Reviewed-by: NHeiko Carstens <hca@linux.ibm.com> Signed-off-by: NSven Schnelle <svens@linux.ibm.com> Signed-off-by: NHeiko Carstens <hca@linux.ibm.com>